Displaying 3 results from an estimated 3 matches for "florescent".
Did you mean:
fluorescent
2006 Apr 24
1
Pinouts for T1/E1 crossover cable WAS "RE: what cable to connect a legacy PBX to a TE410P ?"
...-8859-1; format=flowed
>
> Rich Adamson wrote:
>
> > <snip>
> > For short runs, the use of cat5 vs proper T1 cables isn't likely to
> > have any impact unless there is a fair amount of induction from
> > electrical noise, etc. That can take the form of florescent
> fixtures,
> > transformers, older CRT monitors, etc, etc.
> >
> > On longer runs, the shielded T1 cables are likely to provide better
> > results particularly if there happens to be any electrical noise.
> >
> > Oh, and if shielded T1 cable is used, the s...
2006 Apr 22
4
Pinouts for T1/E1 crossover cable WAS "RE: what cable to connect a legacy PBX to a TE410P ?"
Can't anyone stop self-promotion and tell the poor guy what he needs.
A T1/E1 X-over cable using an RJ-45 (8-cond.) is pinned out as follows:
1 - 4
2 - 5
3 - NU
4 - 1
5 - 2
6 - NU
7 - NU
8 - NU
NU = Not Used
I have not in my experience seen any problems with using a Good Quality
Cat5 vs. Cat 3 (telco standard) cable for X-connects. YMMV, but you
should be fine. As far as the shielding
2004 Dec 07
9
Analog FXO Woes Continue
I've been struggling with a test * install for a couple months now in a
small office and am just about ready to give up on it. It's not that the
system itself is a problem. I've got everything (attendant, voicemail,
FXS extensions, Cisco and Polycom hard-IP phones, and 2 VOIP carriers)
working except for the frigging analog FXO interfaces. These things are
driving me completely mad.