2014 Jul 11
2
CDR(dst) not set in AEL macro
Hi
I'm using a macro to dial in a AEL dialplan. The problem is the macro do
not set the field CDR(dst), showing only ~~s~~.
I tried various configurations, but without solutions.
This is the macro:
macro dial-out(destno,dialstring,route_descr,interno) {
__TRANSFER_CONTEXT=ipbx;
if(${interno} = 1) {
Set(__PICKUPMARK=${destno});
if(${ODBC_verify_user(${CALLERID(num)})} > 0) {
t = tT;
}