search for: ewerk

Displaying 5 results from an estimated 5 matches for "ewerk".

2019 Aug 08
1
Re: OVS / KVM / libvirt / MTU
On Thu, 8 Aug 2019 at 10:08, Sven Vogel <S.Vogel@ewerk.com> wrote: > The question for me is why they use the smallest? > Because otherwise some frames won't get through because the interface can't receive them, and the job of network equipment is to enable and maintain communication :-). > > Cheers > > Sven > - Peter...
2019 Aug 08
0
Re: OVS / KVM / libvirt / MTU
Hi Alvin, Thanks for the help. :) This sounds good. My head also wrap about this problem. The question for me is why they use the smallest? Cheers Sven __ Sven Vogel Teamlead Platform EWERK DIGITAL GmbH Br?hl 24, D-04109 Leipzig P +49 341 42649 - 11 F +49 341 42649 - 18 S.Vogel@ewerk.com www.ewerk.com Gesch?ftsf?hrer: Dr. Erik Wende, Hendrik Schubert, Frank Richter Registergericht: Leipzig HRB 17023 Zertifiziert nach: ISO/IEC 27001:2013 DIN EN ISO 9001:2015 DIN ISO/IEC 20000-1:2011...
2019 Jul 31
2
Re: OVS / KVM / libvirt / MTU
In general if no MTU is set on interface creation the default value is 1500. On OVS the bridge MTU is automatically set to the smallest port MTU. So you just have to set the MTU of each port of the bridge. Take a look at: https://bugzilla.redhat.com/show_bug.cgi?id=1160897 It is a bit of a pain to read but seems to confirm the statement about the OVS MTU value being set by the MTU of the
2019 Jul 23
2
OVS / KVM / libvirt / MTU
...: [] name : "cloudbr0" ofport : 65534 —MTU of the vnet interface mac_in_use : "fe:00:74:76:00:01" mtu : 1450 mtu_request : 1450 name : „vnet2" Thanks for help… __ Sven Vogel Teamlead Platform EWERK RZ GmbH Brühl 24, D-04109 Leipzig P +49 341 42649 - 11 F +49 341 42649 - 18 S.Vogel@ewerk.com www.ewerk.com Geschäftsführer: Dr. Erik Wende, Hendrik Schubert, Frank Richter Registergericht: Leipzig HRB 17023 Zertifiziert nach: ISO/IEC 27001:2013 DIN EN ISO 9001:2015 DIN ISO/IEC 20000-1:2011 EWER...
2019 Jul 29
2
Re: OVS / KVM / libvirt / MTU
...he bridge will change too. Before the bridge was e.g. by 9000. I ask because you wrote if I don’t set an mtu of the interface I will get the mtu of the bridge. But it seems so. Can you clarify it a little better for me? Cheers Sven Von meinem iPhone gesendet __ Sven Vogel Teamlead Platform EWERK RZ GmbH Brühl 24, D-04109 Leipzig P +49 341 42649 - 11 F +49 341 42649 - 18 S.Vogel@ewerk.com www.ewerk.com Geschäftsführer: Dr. Erik Wende, Hendrik Schubert, Frank Richter Registergericht: Leipzig HRB 17023 Zertifiziert nach: ISO/IEC 27001:2013 DIN EN ISO 9001:2015 DIN ISO/IEC 20000-1:2011 EWER...