Displaying 9 results from an estimated 9 matches for "ellipsemax".
2018 Dec 01
2
MGE EllipseMAX 1500 shuts down after a few hours
The UPS is connected to the following environment:
OS: Debian GNU/Linux 9.6 (stretch)
NUT version: 2.7.4-5
Device output from lsusb: 0463:ffff MGE UPS Systems UPS
Model name: MGE EllipseMAX 1500
URLs:
http://powerquality.eaton.com/Products-services/Backup-Power-UPS/Ellipse-MAX-eol.aspx?cx=97&GUID=7BB6CD53-9F6D-4D62-B326-1099F137BF8D
http://powerquality.eaton.com/68558.aspx?cx=97
The problem is that at some point, after being online for a while, the
UPS shuts down, cutting the po...
2018 Dec 02
4
MGE EllipseMAX 1500 shuts down after a few hours
...opening a trouble
> ticket with Eaton. It is possible that there is a known issue and/or
> a firmware upgrade.
What kind of message to NUT? In the log (syslog) there is no other
message registered. In nut.log only this appears:
> Dec 1 08:10:54 openmediavault upsd[5284]: Data for UPS [ellipsemax]
> is stale - check driver
> Dec 1 08:10:56 openmediavault upsmon[5313]: Poll UPS
> [ellipsemax at localhost] failed - Data stale
> Dec 1 08:10:56 openmediavault upsmon[5313]: Communications with UPS
> ellipsemax at localhost lost
> Dec 1 08:10:56 openmediavault upssched[109...
2018 Dec 02
0
MGE EllipseMAX 1500 shuts down after a few hours
...enmediavault:
> Subject: [openmediavault.local] UPS notification from openmediavault
> Dec 2 18:40:05 openmediavault kernel: [51569.428523] usb 1-2: usbfs:
> USBDEVFS_CONTROL failed cmd usbhid-ups rqt 161 rq 1 len 6 ret -110
> Dec 2 18:40:12 openmediavault upsd[20509]: Data for UPS [ellipsemax]
> is stale - check driver
> Dec 2 18:40:13 openmediavault kernel: [51577.620729] usb 1-2: usbfs:
> USBDEVFS_CONTROL failed cmd usbhid-ups rqt 161 rq 1 len 5 ret -110
> Dec 2 18:40:14 openmediavault upsmon[20537]: Poll UPS
> [ellipsemax at localhost] failed - Data stale
> Dec...
2018 Dec 01
0
MGE EllipseMAX 1500 shuts down after a few hours
On Dec 1, 2018, at 3:45 PM, raul <raulvior.bcn at gmail.com> wrote:
>
> The UPS is connected to the following environment:
> OS: Debian GNU/Linux 9.6 (stretch)
> NUT version: 2.7.4-5
> Device output from lsusb: 0463:ffff MGE UPS Systems UPS
> Model name: MGE EllipseMAX 1500
> URLs:
> http://powerquality.eaton.com/Products-services/Backup-Power-UPS/Ellipse-MAX-eol.aspx?cx=97&GUID=7BB6CD53-9F6D-4D62-B326-1099F137BF8D
> http://powerquality.eaton.com/68558.aspx?cx=97
>
> The problem is that at some point, after being online for a while, the UPS s...
2018 Dec 02
0
MGE EllipseMAX 1500 shuts down after a few hours
On Dec 1, 2018, at 10:08 PM, raul <raulvior.bcn at gmail.com> wrote:
>
>> Also, given that the load is only 12%, double-check that the UPS is not configured for any power saving features that might cause the shutdown ("ECO mode" or similar). NUT does not get a notification for that event the way that it gets a normal LB shutdown notification.
>
> Are you referring
2018 Dec 03
0
MGE EllipseMAX 1500 shuts down after a few hours
On Dec 2, 2018, at 7:55 PM, raul <raulvior.bcn at gmail.com> wrote:
>
> I have taken out the batteries and measured them with a multimeter. They put out 13V (they are rated 12V 9Ah).
What sort of load did you have in parallel with the multimeter? (This is why Wolfy mentioned the light bulb: if the battery has developed excessive internal resistance, it will show proper voltages when
2018 Dec 02
1
MGE EllipseMAX 1500 shuts down after a few hours
On December 2, 2018 7:29:38 PM GMT+02:00, raul <raulvior.bcn at gmail.com> wrote:
>I have restored original configuration and enabled the ignorelb flag. I
>
>didn't point out in the original e-mail that after every poweroff the
>battery percentage is reported at 40% instead of 100% and charges
>slowly again to 100%. Maybe the UPS sends a LB event and shuts down
2018 Dec 03
2
MGE EllipseMAX 1500 shuts down after a few hours
I have taken out the batteries and measured them with a multimeter.
They put out 13V (they are rated 12V 9Ah).
Putting them back again and disconnecting the UPS from the mains it is
kept on, powering all the connected devices.
The shutdowns only occur when the UPS is being monitored. Are you sure
it's a battery problem? Do UPS perform further tests when they are
being polled for data?
2011 Nov 17
3
UPS MGE serial cable over network.
...2011 08:21, "Management" <management at multikreatif.net> a ?crit?:
>
> Hi,
>
> Please forgive me by emailing this to you.? I am not sure you are the one who also program the ?Personal? Solution_Pac? software. If you do, I have a question on it.
> ?I have MGE (eaton) EllipseMax 1500. I want to monitor the UPS remotely. The device I use is a serial over IP .? The setting looks like this :
>
> UPS --> Standard MGE serial cable --> serial over IP --> internet --> PC running virtual com port & Personal Solution-Pac (windows xp)
>
> it can not work....