Displaying 5 results from an estimated 5 matches for "dtr0rts1".
2007 Dec 29
1
Odd Values For Powercoms
...powercom
driver.parameter.batteryPercentage: {5.0000,0.3268,-825.00,0.46511,0}
driver.parameter.frequency: {0.00020997,0.0}
driver.parameter.linevoltage: 110
driver.parameter.loadPercentage: {6.1343,-0.3808,1.075,0.1811}
driver.parameter.manufacturer: PowerCom
driver.parameter.methodOfFlowControl: dtr0rts1
driver.parameter.numOfBytesFromUPS: 16
driver.parameter.pollinterval: 2
driver.parameter.port: /dev/cuaa0
driver.parameter.shutdownArguments: {{0,10},n}
driver.parameter.type: KIN2200AP
driver.parameter.validationSequence: {{7,0},{8,0},{8,0}}
driver.parameter.voltage: {1.9216,-0.0977,0.82857,0.0000...
2005 Dec 30
2
BNT600AP
...uments:
manufacturer : 'PowerCom'
model name : 'Unknown'
serial number : 'Unknown'
line voltage : '230'
type : 'Trust'
number of bytes from UPS: '11'
method of flow control : 'dtr0rts1'
validation sequence: '{{5,0},{7,0},{8,0}}'
shutdown arguments: '{{0,10},n}'
frequency calculation coefficients: '{0.000210,0.000209}'
load percentage calculation coefficients:
'{6.134300,-0.380800,4.311000,0.181100}' battery percentage calculation
coefficien...
2011 Jul 08
2
Ubuntu 10.04 Ultra 700VA UPS Setup Nut
...OM
Co.,LTD HID UPS Battery] on usb-0000:00:1d.0-1/input0
Here's my etc/nut/ups.conf file:
Code:
# /etc/nut/ups.conf
[Ultra]
driver = powercom
port = port=/dev/hidraw1
linevoltage = 120
manufacturer = Ultra
modelname = ULTRA 700VA
type = Trust
methodOfFlowControl=dtr0rts1
shutdownArguments = {{7,10},y}
Here's what I get when I run sudo upsdrvctl start:
Code:
eric at eric-desktop:~$ sudo upsdrvctl start
Network UPS Tools - UPS driver controller 2.4.3
Network UPS Tools - PowerCom protocol UPS driver 0.12 (2.4.3)
Unable to open port=/dev/hidraw1: No such f...
2006 Aug 18
0
(no subject)
...ents:
manufacturer : 'PowerCom'
model name : 'Unknown'
serial number : 'Unknown'
line voltage : '220'
type : 'KP625AP'
number of bytes from UPS: '16'
method of flow control : 'dtr0rts1'
validation sequence: '{{5,0x80},{7,0},{8,0}}'
shutdown arguments: '{{1,0},y}'
frequency calculation coefficients: '{0.000210,0.000209}'
load percentage calculation coefficients: '{6.134300,-0.380800,4.311000,0.181100}'
battery percentage calculation coeffic...
2011 Jul 19
2
KIN-1500AP RM + Windows 2008 64-bit Standard R2 SP1 (nut 2.6.1)
I have only RS-232 on the box (meanwhile, it was manufactured on march of
2011)
Here is my configs:
nut.conf:
*
*
MODE = netserver
ups.conf:
*
*
[KIN1500]
driver = powercom
port = notUsed
desc = "Powercom KING PRO KIN-1500AP RM"
upsd.conf:
*
*
LISTEN 192.168.1.2 3493
upsd.users:
*
*
[monuser]
password = xxxxxxxx
upsmon master