search for: dtr0rts1

Displaying 5 results from an estimated 5 matches for "dtr0rts1".

2007 Dec 29
1
Odd Values For Powercoms
...powercom driver.parameter.batteryPercentage: {5.0000,0.3268,-825.00,0.46511,0} driver.parameter.frequency: {0.00020997,0.0} driver.parameter.linevoltage: 110 driver.parameter.loadPercentage: {6.1343,-0.3808,1.075,0.1811} driver.parameter.manufacturer: PowerCom driver.parameter.methodOfFlowControl: dtr0rts1 driver.parameter.numOfBytesFromUPS: 16 driver.parameter.pollinterval: 2 driver.parameter.port: /dev/cuaa0 driver.parameter.shutdownArguments: {{0,10},n} driver.parameter.type: KIN2200AP driver.parameter.validationSequence: {{7,0},{8,0},{8,0}} driver.parameter.voltage: {1.9216,-0.0977,0.82857,0.0000...
2005 Dec 30
2
BNT600AP
...uments: manufacturer : 'PowerCom' model name : 'Unknown' serial number : 'Unknown' line voltage : '230' type : 'Trust' number of bytes from UPS: '11' method of flow control : 'dtr0rts1' validation sequence: '{{5,0},{7,0},{8,0}}' shutdown arguments: '{{0,10},n}' frequency calculation coefficients: '{0.000210,0.000209}' load percentage calculation coefficients: '{6.134300,-0.380800,4.311000,0.181100}' battery percentage calculation coefficien...
2011 Jul 08
2
Ubuntu 10.04 Ultra 700VA UPS Setup Nut
...OM Co.,LTD HID UPS Battery] on usb-0000:00:1d.0-1/input0 Here's my etc/nut/ups.conf file: Code: # /etc/nut/ups.conf [Ultra] driver = powercom port = port=/dev/hidraw1 linevoltage = 120 manufacturer = Ultra modelname = ULTRA 700VA type = Trust methodOfFlowControl=dtr0rts1 shutdownArguments = {{7,10},y} Here's what I get when I run sudo upsdrvctl start: Code: eric at eric-desktop:~$ sudo upsdrvctl start Network UPS Tools - UPS driver controller 2.4.3 Network UPS Tools - PowerCom protocol UPS driver 0.12 (2.4.3) Unable to open port=/dev/hidraw1: No such f...
2006 Aug 18
0
(no subject)
...ents: manufacturer : 'PowerCom' model name : 'Unknown' serial number : 'Unknown' line voltage : '220' type : 'KP625AP' number of bytes from UPS: '16' method of flow control : 'dtr0rts1' validation sequence: '{{5,0x80},{7,0},{8,0}}' shutdown arguments: '{{1,0},y}' frequency calculation coefficients: '{0.000210,0.000209}' load percentage calculation coefficients: '{6.134300,-0.380800,4.311000,0.181100}' battery percentage calculation coeffic...
2011 Jul 19
2
KIN-1500AP RM + Windows 2008 64-bit Standard R2 SP1 (nut 2.6.1)
I have only RS-232 on the box (meanwhile, it was manufactured on march of 2011) Here is my configs: nut.conf: * * MODE = netserver ups.conf: * * [KIN1500] driver = powercom port = notUsed desc = "Powercom KING PRO KIN-1500AP RM" upsd.conf: * * LISTEN 192.168.1.2 3493 upsd.users: * * [monuser] password = xxxxxxxx upsmon master