Displaying 7 results from an estimated 7 matches for "dl360g5".
Did you mean:
dl360g2
2009 Sep 09
4
waiting IOs...
Hi,
We have a storage server (HP DL360G5 + MSA20 (12 disks in RAID 6) on a SmartArray6400).
10 directories are exported through nfs to 10 clients (rsize=32768,wsize=32768,soft,intr,nosuid,proto=udp,vers=3).
The server is apparently not doing much but... we have very high waiting IOs.
dstat show very little activity, but high 'wai'...
2007 May 14
3
Number of xenbr''s limited to four on openSuSE 10.2 ?
Hi Group
...
havin'' read whatever I could "google" on this
topic, I didn`t find any
solution:
openSuSE 10.2 (out
of the box), xenkernel, running on HP Proliant DL360G5
(dual
internal networking, plus additional 4-port adapter) gives me eth0 -
eth5, but only peth0 - peth3 (as well as vif0 - vif3 and consequentely
xenbr0 - xenbr3).
I increased the number of
loopback-devices to 64 ... no result
Whenever I try to
"/etc/xen/scripts/network-bridge start vifnu...
2010 Mar 05
4
Syslinux 3.85 chain.c32 problem solved
Thanks to debugging information from Thomas Mieslinger, I have
root-caused the failure of chain.c32 in Syslinux 3.85. I have put out
Syslinux 3.86-pre1 and Syslinux 4.00-pre33 which fix the problem.
I expect to release a Syslinux 3.86 relatively shortly (ideally in the
next two weeks), with bug fixes only. I would like to figure out if
there are other bug fixes we can get in in reasonable time,
2013 Apr 30
3
flashing a BIOS on an HP server
Hi, folks,
Since I've gotten a total of one response in days on the HP forum,
maybe the collective mind here has an answer.... As I've mentioned in
other posts, we have an HP dl580 g5 that started throwing ECC errors.
But wait, it's worse: memory is mirrored.... And the thing is fully
populated with 32 DIMMs.
I took my best guess, pulled the matching set of DIMMs, and took two
2007 Jul 29
1
6 node cluster with unexplained reboots
We just installed a new cluster with 6 HP DL380g5, dual single port Qlogic 24xx HBAs connected via two HP 4/16 Storageworks switches to a 3Par S400. We are using the 3Par recommended config for the Qlogic driver and device-mapper-multipath giving us 4 paths to the SAN. We do see some SCSI errors where DM-MP is failing a path after get a 0x2000 error from the SAN controller, but the path gets puts
2009 Jan 23
13
which server to buy?
Hello!
Please, help me, I''m totally lost choosing basic budget server for XEN.
The variants are Sun (X2200 M2 or Sun X2250 M2) or maybe HP Proliant
DL160 G5p. Or maybe some IBM server?
Which X2200 configuration will perform better, two Opteron dual-core
22xx or single quad-core 23xx?
Which one performing better nowadays, Opteron or Xeon? I know that 2-3
years ago Opteron was the
2013 Mar 25
2
gptzfsboot: error 4 lba 30
Hi.
On one of my fresh installed servers I am seeing the following output during boot:
gptzfsboot: error 4 lba 30
gptzfsboot: error 4 lba 31
gptzfsboot: error 4 lba 31
gptzfsboot: error 4 lba 31
gptzfsboot: error 4 lba 30
gptzfsboot: error 4 lba 31
gptzfsboot: error 4 lba 31
gptzfsboot: error 4 lba 31
gptzfsboot: error 4 lba 31
gptzfsboot: error 4 lba 31
gptzfsboot: error 4 lba 31
gptzfsboot: