Displaying 20 results from an estimated 370 matches for "discharg".
Did you mean:
discharge
2008 Aug 12
2
Parsing array data
...quot;"),header=T,sep=",")
This allows me to load the data into an array of length 3, with the res array containing my data from the csv files.
I would like to parse the data in the res array so that I can access my specific data columns. For instance, I have field names called 'Discharge,' 'Volume,' and 'Id'. I would like to aggregate these fields for all the loaded files in the array so that I can perform some basic comparisons of distributions, etc.
Does anyone have any example code that would allow me to parse the array so that I can extract the column names...
2009 Feb 18
1
rbind: number of columns of result is not a multiple of vector length (arg 1)
i have the following constructed and running very well,, thanks to Gabor
Grothendieck for his help.
>data.info <- c("station.id", "year", "date", "max.discharge")
>
> for(i in 1:num.files) {
+ station.id <- substring(data[i], 1,8)
+ DF <- read.table(data[i], sep=",", blank.lines.skip = TRUE)
+ z <- zoo(DF[,4], as.Date(as.character(DF[,3]), "%m/%d/%Y"))
+ f <- function(x) time(x) [which.max(x)]
+ ix <- tapply(z...
2010 May 18
2
Function that is giving me a headache- any help appreciated (automatic read )
...take advantage of
#the agency column)
L.USGS <- grep("^USGS", L, value = TRUE)
DF <- read.table(textConnection(L.USGS), fill = TRUE)
colnames(DF) <- c("agency", "gauge", "date", "time", "time_zone",
"gauge_height",
"discharge", "precipitation")
pat <- "^# +USGS +([0-9]+) +(.*)"
L.DD <- grep(pat, L, value = TRUE)
library(gsubfn)
DD <- strapply(L.DD, pat, c, simplify = rbind)
DDdf <- data.frame(gauge = as.numeric(DD[,1]), gauge_name = DD[,2])
both <- merge(DF, DDdf, by = "gaug...
2009 Oct 06
1
ggplot2 applying a function based on facet
Look at the bottom of the message for my question
#here is a little function that I wrote
USGS <- function(input="discharge", days=7){
library(chron)
library(gsubfn)
#021973269 is the Waynesboro Gauge on the Savannah River Proper (SRS)
#02102908 is the Flat Creek Gauge (ftbrfcms)
#02133500 is the Drowning Creek (ftbrbmcm)
#02341800 is the Upatoi Creek Near Columbus (ftbn)
#02342500 is the Uchee Creek Near Fort Mit...
2013 Feb 19
1
data format
...a.frame(date1=seq.Date(as.Date("1930.1.1",format="%Y.%m.%d"),as.Date("2010.12.31",format="%Y.%m.%d"),by="day"))
elsplit1<- lapply(elsplit,function(x) data.frame(date1=as.Date(paste(x[,2],x[,3],x[,4],sep="-"),format="%Y-%m-%d"),discharge=x[,5]))
?elsplit2<-lapply(elsplit1,function(x) x[order(x[,1]),])
library(plyr)
elsplit3<-lapply(elsplit2,function(x) join(datetrial,x,by="date1",type="full"))
?elsplit4<-lapply(elsplit3,function(x) {x[,2][is.na(x[,2])]<- "-9999.000";x})
elsplit5<-lapply...
2009 Feb 17
2
annual maximum value
hi everyone!
hope you can help me here.
i am a new R user. what i am trying to do is to find the maximum annual
discharge from a daily record. i have a data.frame which includes date and
the discharge. somewhat like this..
10/1/1989 2410
10/2/1989 2460
10/3/1989 2890
...
...
...
12/31/2005 5730
i have been browsing through the archives and fount out about the aggregate
function and the zoo pac...
2009 Dec 13
0
need a solution to an R-problem: consultant available?
...t;F:/R_code/exampledata.txt")
#head(data) # shows header
attach(data) #attaches data to current run
datasort=data[order(Stage), ] #sorts data so predicted values follow in
systematic order
#datasort # shows sorted data
starts = list(const =0.00001, alpha = 20)
fm <- nls(Discharge ~ const*Stage ^alpha, start=starts) #runs a non linear
least squares regression model
#predict(fm) # fitted values at observed times
#summary(fm)
coef=coefficients(fm)
const_val=round(coef["const"],4) #makes a variable for the equation in the
plot and rounds it to...
2004 Jul 07
3
KalmanSmooth problem
Hello,
In R I am trying to use Kalman filtering to find a solution for an hydrological problem. With Kalman Filtering I want to estimate the discharge comming from three storage bassins. I have programmed a function in R which can run KalmanSmooth. When I'm asking for the function and putting in values, R detects the following error: "Error in as.vector(data) : Argument "S1" is missing, with no default".
I have try to fin...
2008 Feb 20
2
MGE pulsar evolution 3000 discharges without nut noticing
...9.0 [OL DISCHRG] NA 60.00
20080219 063459 019.0 122.8 049.0 [OL DISCHRG] NA 60.00
20080219 183013 100.0 121.1 050.0 [OL CHRG] NA 60.00
20080219 183043 100.0 120.9 049.0 [OL CHRG] NA 60.00
the good news is the UPS held up for four hours.
the bad news is that nut completely ignored that the UPS was
discharging, and none of my connected machines shut down properly. I
know that the UPS driver was running, because if was not, upsd would
have complained loudly and frequently. I know upsd was running (on the
connected server as well as all the clients), because if it was not,
upsmon would have complained...
2008 Sep 09
1
Linear Modeling the best alternative
I have a data set of mean velocity, discharge, and mean depth. I need
to find out which model best fits them out of log linear, linear, some
other kind of model... Using excel I have found that linear is not
that bad and log10(discharge) vs. the other two variables (I am trying
to predict velocity and depth from discharge) is not that bad e...
2020 Jan 11
4
System with MGE UPS shuts down too early
OK. I'll try it, but it really puzzles me how the battery could have
gone bad for just 15 months. The online power is pretty stable, so the
battery hasn't gone through many charge/discharge cycles...
Regards,
--
Georgi
On 11.1.2020 at 14:24, Manuel Wolfshant wrote:
>
> indicates that the UPS thought that battery was close to depleted and decided to shutdown. I suggest to fully retest your battery ( doing a full charge/discharge cycle with a dummy load ), I suspect it is not...
2011 May 11
1
filtering out unwanted words in a Term Document Matrix
...uot;physician", "orders", "treatment", "times", "care", "plan", "strategies", "concerns", "meetings", "equipment", "treatment", "options", "delivery", "care", "discharge", "welfare", "violations", "HIPPS", "professionalism", "lack", "boundaries crossing", "transportation", "benefits", "assistance", "beneficiary", "complaint", "grievance", &q...
2008 Dec 04
1
Battery Volts shown as 20+ on Cyber Power UPS CP1000AVRLCD [ DATA ]
Citeren "David C. Rankin" <drankinatty at suddenlinkmail.com>:
> Discharged battery.voltage:
>
> 17.4 Volts - (indicated on shutdown, discharging battery.charge 77%)
> 16.9 Volts - (indicated on shutdown, discharging battery.charge 51%%)
> 16.6 Volts - (indicated on shutdown, discharging battery.charge 33%)
>
> -- Shutdown Occurred at < 3% --...
2012 Jul 05
2
function curve() swap axes
Dear all,
I'm using the curve() function to plot discharge Q against water depth a.
However, I would like to have a graph of water depth a plotted against
discharge Q. How can this be done?
Minimal working example:
S0 = 0.004
n = 0.04
tanalpha = 1.4/1.5
par(mar = c(5,5,1,1)) # b, l, t, r
curve((sqrt(S0)/n)*(0.035+(0.7+(x-0.1)/tanalpha)*(x-0.1))*((0.035+(0...
2011 Mar 18
1
Difficulty with 'loess' function
Hi,
I am trying to create a loess smooth from hydrologic data. My goal is to
create a smooth line that describes discharge at a certain point in time. I
have done this using the 'lowess' function and had no problem, but I'm
having some difficulty with loess. I am inputting the date ('date') and
discharge ('q') values using the 'scan' function, then inputting the
following:
> d...
2007 May 03
4
Re: Changes to megatec.c
...ended by sealed lead acid battery manufacturers
should keep it under 42V. Overcharged or worn batteries might have a
highere clamping voltage, but more than 42V will move it into the
regions of 48V power supplies.
- Battery manufacturers recommend a minimum of 10.8V for a 12V battery
as the cutoff discharge voltage (further discharge will cause battery
damage) but the UPS is likely to shut off before that, so I
guesstimated 11V for a 12V cell to be a reasonable "empty battery"
voltage.
- The float charge (clamping) voltage for a fully charged 36V battery
if 40.9V but I've subtracted 1...
2007 May 06
2
battery discharge too fast
From the moment when the UPS rapports "Low Battery" to the end of the
shutdown, too mutch time is passing.
So the computer does not have enough time shut down properly.
Can I shut down the computer on the "On Batery" status?
Or can I shut down when the UPS rapports 50% of the battery?
Thank you.
2014 Dec 19
1
Changing self test date
On Dec 18, 2014, at 9:16 AM, Frantz de Germain <frantz at info.univ-angers.fr> wrote:
> What is the difference between "test.battery.start.deep" and
> "test.battery.start.quick" command (upscmd) ?
The intent for the quick test is to only discharge the battery a little bit, whereas the deep test would discharge until the low battery threshold is reached (or the test is stopped).
In practice, the difference is determined by the UPS firmware.
--
Charles Lepple
clepple at gmail
2024 Nov 13
5
Eaton 5PX 3rd party batteries
...tteries claim 12V, but they are charged to over 13V).
I like batteries from RaionGroup.com or batterywholesale.com.
There are some other companies out there that I will never buy from again.
I try to get high-rate batteries, and they are harder to find. As I
recall, one should avoid "deep discharge" batteries for UPSes. A deep
discharge battery is great for constant load stuff (like wheelchairs,
golf carts, etc) but UPSes need "shorter" bursts of lots of power.
I read the spec sheets and order the heaviest batteries I can find.
More lead means heavier batteries, and longe...
2003 May 14
2
number of patients in a hospital on a given date
Dear R-users!
I am using R 1.7.0, under Windows XP.
Having some hospital discharge data (admission date and discharge date for
each patient), I want to get the number of patients in the hospital on a
given date.
My data look like (simple example):
> x <- data.frame(patid=c("pat1", "pat2"), adm.date = c("15.03.2002",
"16.03.2002"),...