search for: delaybeforereboot

Displaying 20 results from an estimated 46 matches for "delaybeforereboot".

2019 Dec 08
3
Tripp Lite SMART1500LCD repeatedly disconnecting and reconnecting
...74 Path: UPS.PowerConverter.PresentStatus.InternalFailure, Type: Feature, ReportID: 0x22, Offset: 7, Size: 1, Value: 0 0.208022 Path: UPS.PowerConverter.PresentStatus.AwaitingPower, Type: Feature, ReportID: 0x22, Offset: 14, Size: 1, Value: 0 0.210000 Path: UPS.OutletSystem.Outlet.DelayBeforeReboot, Type: Feature, ReportID: 0x17, Offset: 0, Size: 16, Value: 65535 0.211982 Path: UPS.OutletSystem.Outlet.PercentLoad, Type: Feature, ReportID: 0x1e, Offset: 0, Size: 8, Value: 17 0.212168 Report descriptor retrieved (Reportlen = 662) 0.212289 Found HID device 0.212410 De...
2015 Jan 09
0
persistent "low battery" condition
On Jan 8, 2015, at 11:43 PM, Graham Menhennitt <graham at menhennitt.com.au> wrote: > Hello Nutters, > > I'm running nut 2.7.2 on FreeBSD 10-stable (via the FreeBSD port) with an APC Back-UPS CS 350 connected via USB. I get persistent (every few minutes) messages logged "battery is low" but I don't understand why. I don't think it's for the reason
2015 Jan 09
2
persistent "low battery" condition
...erSummary.RunTimeToEmpty, Type: Input, ReportID: 0x0d, Offset: 0, Size: 16, Value: 105 163.183686 Quick update... 163.190347 Path: UPS.PowerSummary.DelayBeforeShutdown, Type: Feature, ReportID: 0x12, Offset: 0, Size: 16, Value: -1 163.201247 Path: UPS.PowerSummary.DelayBeforeReboot, Type: Feature, ReportID: 0x13, Offset: 0, Size: 24, Value: 0 163.210345 Path: UPS.Output.DelayBeforeStartup, Type: Feature, ReportID: 0x28, Offset: 0, Size: 16, Value: 0 163.221472 Path: UPS.PowerSummary.PresentStatus.ACPresent, Type: Feature, ReportID: 0x07, Offset:...
2015 Jan 12
2
persistent "low battery" condition
...et: 0, Size: 24, Value: 263941 771.764677 Path: UPS.Output.PercentLoad, Type: Feature, ReportID: 0x2c, Offset: 0, Size: 16, Value: 73 771.784792 Path: UPS.PowerSummary.DelayBeforeShutdown, Type: Feature, ReportID: 0x12, Offset: 0, Size: 16, Value: -1 771.804859 Path: UPS.PowerSummary.DelayBeforeReboot, Type: Feature, ReportID: 0x13, Offset: 0, Size: 24, Value: 0 771.824650 Path: UPS.Output.DelayBeforeStartup, Type: Feature, ReportID: 0x28, Offset: 0, Size: 16, Value: 0 771.833660 Path: UPS.Battery.Test, Type: Feature, ReportID: 0x16, Offset: 0, Size: 8, Value: 6 771.844717 Path: U...
2017 Aug 21
5
TrippLite SMART1500LCD no delay before ups shutdown.
...0 Path: UPS.PowerConverter.PresentStatus.InternalFailure, Type: Feature, ReportID: 0x22, Offset: 7, Size: 1, Value: 0 0.164312 Path: UPS.PowerConverter.PresentStatus.AwaitingPower, Type: Feature, ReportID: 0x22, Offset: 14, Size: 1, Value: 0 0.164733 Path: UPS.OutletSystem.Outlet.DelayBeforeReboot, Type: Feature, ReportID: 0x17, Offset: 0, Size: 16, Value: 65535 0.165291 Path: UPS.OutletSystem.Outlet.PercentLoad, Type: Feature, ReportID: 0x1e, Offset: 0, Size: 8, Value: 0 0.165302 Report descriptor retrieved (Reportlen = 662) 0.165303 Found HID device 0.165305 D...
2010 Nov 07
3
Support of "shutdown.return" on a APC Back-UPS CS 500
Hi all, I am trying to get a APC Back-UPS CS 500 running on my QNAP 419P Nas. Since on all my work I figure out the following: from Network UPS Tools upscmd 2.4.1 [~] # upscmd -l qnapups Instant commands supported on UPS [qnapups]: beeper.disable - Disable the UPS beeper beeper.enable - Enable the UPS beeper beeper.mute - Temporarily mute the UPS beeper beeper.off - Obsolete (use
2017 Dec 18
2
Tripp-Lite BCPERS450 shutdown/restart problems
...0 0.083777 Path: UPS.PowerConverter.PresentStatus.InternalFailure, Type: Feature, ReportID: 0x22, Offset: 7, Size: 1, Value: 0 0.083799 Path: UPS.PowerConverter.PresentStatus.AwaitingPower, Type: Feature, ReportID: 0x22, Offset: 14, Size: 1, Value: 0 0.084531 Path: UPS.OutletSystem.Outlet.DelayBeforeReboot, Type: Feature, ReportID: 0x17, Offset: 0, Size: 16, Value: 65535 0.084569 Report descriptor retrieved (Reportlen = 613) 0.084578 Found HID device 0.084591 Detected a UPS: Tripp Lite /Tripp Lite UPS 0.084664 Path: UPS.PowerSummary.RemainingCapacity, Type: Feature, ReportID: 0x34, Offse...
2013 Aug 07
4
HP R1500 G3 problems
...5117 Path: UPS.OutletSystem.Outlet.DelayBeforeShutdown, Type: Feature, ReportID: 0x15, Offset: 0, Size: 16, Value: -1 0.659111 Path: UPS.OutletSystem.Outlet.DelayBeforeStartup, Type: Feature, ReportID: 0x61, Offset: 0, Size: 16, Value: -1 0.663116 Path: UPS.OutletSystem.Outlet.DelayBeforeReboot, Type: Feature, ReportID: 0x17, Offset: 0, Size: 16, Value: -1 0.667106 Path: UPS.OutletSystem.Outlet.PercentLoad, Type: Feature, ReportID: 0x1e, Offset: 0, Size: 8, Value: 0 0.671116 Path: UPS.ffff0010.[1].ffff007f, Type: Feature, ReportID: 0x0d, Offset: 0, Size: 8, Value: 6...
2010 Jul 20
2
APC 5G UPS APC-HID
I've grabbed a snapshot of NUT from just a couple days ago. Glad to see APC's new 5G UPSes added to the list (though you probably want to add it to the UDEV 52-nut-usbups.rules file as well...). My issues with new APC Smart-UPS units (SMT1000) : Powering-down the unit, whether with upsdrvctl or upscmd will not obey the specified delay in offdelay, or ups.delay.shutdown. Instead, a
2015 Mar 18
0
Problems with NUT 2.7.2 on CentOS 7 and using the Mini-Box OpenUPS
Charles, to your specific points : > The other HID drivers seem to trigger shutdown by writing to the various timers (e.g. UPS.PowerSummary.DelayBeforeReboot). Your firmware seems to have UPS.PowerSummary.PresentStatus.ShutdownRequested, which according to the HID PDC spec, is read/write. I wonder if the firmware responds to this? So are you suggesting if I modify openups-hid.c to include this specific command as an instant command, it may respond? I c...
2015 Aug 15
2
Small patch to scale the values for TRIPP-LITE SMART*LCDT's
Hi, I just decided to fix some scaling issues for my UPS (TRIPP-LITE SMART1500LCDT). Apparently that issue existed for some time (and I knew about it as well:-() See http://thread.gmane.org/gmane.comp.monitoring.nut.devel/6482 for a thread. My little patch is attached (against 2.7.3). It seems to be working better for me but I don't have any other TRIPP-LITE's to test that I did
2015 Aug 15
2
Small patch to scale the values for TRIPP-LITE SMART*LCDT's
Hi, I just decided to fix some scaling issues for my UPS (TRIPP-LITE SMART1500LCDT). Apparently that issue existed for some time (and I knew about it as well:-() See http://thread.gmane.org/gmane.comp.monitoring.nut.devel/6482 for a thread. My little patch is attached (against 2.7.3). It seems to be working better for me but I don't have any other TRIPP-LITE's to test that I did
2015 Mar 18
4
Problems with NUT 2.7.2 on CentOS 7 and using the Mini-Box OpenUPS
..., as it would need to send instant commands! You are correct; I don't see any HU_TYPE_CMD entries in openups-hid.c. I latched on to the other error you mentioned (about claiming the device). The other HID drivers seem to trigger shutdown by writing to the various timers (e.g. UPS.PowerSummary.DelayBeforeReboot). Your firmware seems to have UPS.PowerSummary.PresentStatus.ShutdownRequested, which according to the HID PDC spec, is read/write. I wonder if the firmware responds to this? > Also from the trace I sent you, it appears that after the ?RunTimeToEmpty? query, the interface tries to read a Report...
2017 Dec 20
3
Tripp-Lite BCPERS450 shutdown/restart problems
...0 0.083408 Path: UPS.PowerConverter.PresentStatus.InternalFailure, Type: Feature, ReportID: 0x22, Offset: 7, Size: 1, Value: 0 0.083427 Path: UPS.PowerConverter.PresentStatus.AwaitingPower, Type: Feature, ReportID: 0x22, Offset: 14, Size: 1, Value: 0 0.083917 Path: UPS.OutletSystem.Outlet.DelayBeforeReboot, Type: Feature, ReportID: 0x17, Offset: 0, Size: 16, Value: 65535 0.083952 Report descriptor retrieved (Reportlen = 613) 0.083962 Found HID device 0.083975 Detected a UPS: Tripp Lite /Tripp Lite UPS 0.084049 Path: UPS.PowerSummary.RemainingCapacity, Type: Feature, ReportID: 0x34, Offse...
2009 Mar 13
7
Weird Load and Battery Temp Readings
...00000000000000000000000000000000000000000.000000 Path: UPS.PowerSummary.DelayBeforeShutdown, Type: Feature, ReportID: 0x12, Offset: 0, Size: 16, Value: -1.000000 Path: UPS.PowerSummary.DelayBeforeShutdown, Type: Feature, ReportID: 0x12, Offset: 0, Size: 16, Value: -1.000000 Path: UPS.PowerSummary.DelayBeforeReboot, Type: Feature, ReportID: 0x13, Offset: 0, Size: 24, Value: 0.000000 Path: UPS.Battery.Test, Type: Feature, ReportID: 0x16, Offset: 0, Size: 8, Value: 6.000000 Path: UPS.PowerSummary.AudibleAlarmControl, Type: Feature, ReportID: 0x14, Offset: 0, Size: 8, Value: 2.000000 Path: UPS.ManufacturerDat...
2020 Jan 01
2
Tripp Lite SMART1500LCD will not stay shut down when power is disconnected
...05 Path: UPS.PowerConverter.PresentStatus.InternalFailure, Type: Feature, ReportID: 0x22, Offset: 7, Size: 1, Value: 0 0.224726 Path: UPS.PowerConverter.PresentStatus.AwaitingPower, Type: Feature, ReportID: 0x22, Offset: 14, Size: 1, Value: 0 0.226683 Path: UPS.OutletSystem.Outlet.DelayBeforeReboot, Type: Feature, ReportID: 0x17, Offset: 0, Size: 16, Value: 65535 0.227422 Path: UPS.OutletSystem.Outlet.PercentLoad, Type: Feature, ReportID: 0x1e, Offset: 0, Size: 8, Value: 0 0.227656 Report descriptor retrieved (Reportlen = 662) 0.227813 Found HID device 0.227999 Det...
2018 Jan 10
0
Tripp-Lite BCPERS450 shutdown/restart problems
...com/networkupstools/nut/blob/v2.7.2/drivers/tripplite-hid.c#L394 (IIRC it's the first match, otherwise it would be https://github.com/networkupstools/nut/blob/v2.7.2/drivers/tripplite-hid.c#L397 ) That sends a value of 10 (likely corresponding to the 10-second delay) to UPS.OutletSystem.Outlet.DelayBeforeReboot The fact that there is not a "UPS.OutletSystem.Outlet.DelayBeforeStartup" or "UPS.OutletSystem.Outlet.TLDelayBeforeStartup" in the debug output for your UPS means that the "wait for power" functionality is probably hidden behind something else, possibly another vendor...
2007 May 13
0
No subject
...it probably always is). According to the HID Power Devices specification, it will do just that and is effectively the same as 'shutdown.stayoff'. If there is mains power at that time, the output will remain off. There are generally two ways to shut down a HID UPS, compatible with NUT: 1) DelayBeforeReboot (shutdown.reboot) 2) DelayBeforeStartup (shutdown.return) and DelayBeforeShutdown (shutdown.stayoff, to make sure the output is off before the startup time= r expires) #1 has the advantage that it is just a single command (but it will act immediately), while #2 allows to shutdown with a delay (mak...
2006 Sep 08
3
newhidups with APC Smart-UPS 1500
Hello, I'm using the stable amd64 port of Debian Linux. I installed (the latest) nut-2.0.1-4 and nut-usb packages for utilizing an APC Smart-UPS 1500 USB. I tried "apcupsd" first but "nut" makes an even more sophisticated impression on me and has more security options. I had problems with the newhidups driver. It didn't find a device with matching VendorID. And
2005 Oct 04
0
Problems connecting to APC/Smart-UPS 3000 RM
...ummary.CapacityGranularity2 Path: UPS.PowerSummary.WarningCapacityLimit Path: UPS.PowerSummary.RemainingCapacityLimit Path: UPS.PowerSummary.ManufacturerDate Path: UPS.PowerSummary.RunTimeToEmpty Path: UPS.PowerSummary.RunTimeToEmpty Path: UPS.PowerSummary.DelayBeforeShutdown Path: UPS.PowerSummary.DelayBeforeReboot Path: UPS.PowerSummary.RemainingTimeLimit Path: UPS.PowerSummary.RemainingTimeLimit Path: UPS.PowerSummary.ConfigVoltage Path: UPS.PowerSummary.Voltage Path: UPS.PowerSummary.AudibleAlarmControl ... This seems to indicate that I have the configuration files correct, but when I try to start but I g...