search for: deepdischargeprotect

Displaying 4 results from an estimated 4 matches for "deepdischargeprotect".

2007 Jun 02
1
MGE evolution s1250 all values = '2'
...lution Using subdriver: MGE HID 1.0 Path: UPS.BatterySystem.Battery.AudibleAlarmControl, Type: Feature, Value: 2.000000 Path: UPS.BatterySystem.Battery.BatteryID, Type: Feature, Value: 2.000000 Path: UPS.BatterySystem.Battery.Count, Type: Feature, Value: 2.000000 Path: UPS.BatterySystem.Battery.DeepDischargeProtection, Type: Feature, Value: 2.000000 Path: UPS.BatterySystem.Battery.DesignCapacity, Type: Feature, Value: 2.000000 Path: UPS.BatterySystem.Battery.PresentStatus.Present, Type: Feature, Value: 2.000000 Path: UPS.BatterySystem.Battery.PresentStatus.Present, Type: Input, Value: 2.000000 Path: U...
2008 Apr 01
1
Incorrect battery status on MGE Pulsar M 3000
...ortID: 0x28, Offset: 0, Size: 8, Value: 2.000000 Path: UPS.BatterySystem.Battery.BatteryID, Type: Feature, ReportID: 0x20, Offset: 0, Size: 8, Value: 1.000000 Path: UPS.BatterySystem.Battery.Count, Type: Feature, ReportID: 0x21, Offset: 0, Size: 8, Value: 1.000000 Path: UPS.BatterySystem.Battery.DeepDischargeProtection, Type: Feature, ReportID: 0x22, Offset: 0, Size: 8, Value: 1.000000 Path: UPS.BatterySystem.Battery.DesignCapacity, Type: Feature, ReportID: 0x23, Offset: 0, Size: 32, Value: 97200.000000 Path: UPS.BatterySystem.Battery.PresentStatus.Present, Type: Feature, ReportID: 0x27, Offset: 0, Size: 8,...
2018 Jan 16
2
Eaton 5PX after battery replacement still says "replace battery" in NUT
...Offset: 0, Size: 8, Value: 2 4.816700 Path: UPS.BatterySystem.Battery.BatteryID, Type: Feature, ReportID: 0x20, Offset: 0, Size: 8, Value: 1 4.850696 Path: UPS.BatterySystem.Battery.Count, Type: Feature, ReportID: 0x21, Offset: 0, Size: 8, Value: 0 4.886600 Path: UPS.BatterySystem.Battery.DeepDischargeProtection, Type: Feature, ReportID: 0x22, Offset: 0, Size: 8, Value: 1 4.925954 Path: UPS.BatterySystem.Battery.DesignCapacity, Type: Feature, ReportID: 0x23, Offset: 0, Size: 32, Value: 32400 4.964082 Path: UPS.BatterySystem.Battery.PresentStatus.Present, Type: Feature, ReportID: 0x27, Offset: 0, S...
2006 Oct 18
2
newhidups with APC Smart-UPS 1500
I tested your fix (newhidups -DDD /dev/null) using both and APC Back-UPS 350 an APC Smart-UPS RT 2000 XL. No more segmentation fault due to the fixed-size array. ~Jacob -----Original Message----- From: nut-upsdev-bounces@lists.alioth.debian.org [mailto:nut-upsdev-bounces@lists.alioth.debian.org] On Behalf Of Peter Selinger Sent: Monday, October 16, 2006 12:12 PM To: Schmier, Jacob Cc: NUT