search for: dchmelik

Displaying 12 results from an estimated 12 matches for "dchmelik".

2018 Jan 21
0
Best Power FE700VA?
On Jan 21, 2018, at 1:12 AM, David Melik <dchmelik at gmail.com> wrote: > > I have an excellent old Best Power FE700VA but am suprised it's unlisted. I thought Best Power ones were for critical applications, mostly for POSIX-based (Unix, etc.) servers, so I want to run it on 64-bit Slackware GNU/Linux. I'm wondering why, or if i...
2018 Mar 23
2
Best Power FE700VA?
On 03/21/2018 07:07 PM, Charles Lepple wrote: > On Mar 20, 2018, at 6:06 PM, David Melik wrote: >> Ok, around 24hrs ago I retested, but the (same) output is still on >> the screen without it going into background to release tty/sh... > My mistake - I misinterpreted the log you posted. Without the "-D" flag, the driver should go into the background in a matter of
2018 Mar 23
0
Best Power FE700VA?
On Mar 22, 2018, at 10:22 PM, David Melik <dchmelik at gmail.com> wrote: > > I assume if I just go through the setup instructions on the NUT website, that'll make the server automatically load this driver on boot. If the Slackware startup scripts call "upsdrvctl start", and the UPS is listed in ups.conf, that should start th...
2018 Jan 21
2
Best Power FE700VA?
I have an excellent old Best Power FE700VA but am suprised it's unlisted.? I thought Best Power ones were for critical applications, mostly for POSIX-based (Unix, etc.) servers, so I want to run it on 64-bit Slackware GNU/Linux.? I'm wondering why, or if it may be added in the future, or if there are any other options.
2013 Oct 02
3
Is USBD necessary for average users?
I followed the NUT instructions that are on the projects site, I think, and they said to set up USBD, so I did. Is that necessary for average users using one PC (rather than servers), or will something not work right if I reread and turn off USBD?
2013 Oct 07
2
Is UPSD necessary for average users?
On Fri, 4 Oct 2013 08:18:12 -0400 Charles Lepple <clepple at gmail.com> wrote: > On Oct 1, 2013, at 11:58 PM, David N Melik wrote: > > > I followed the NUT instructions that are on the projects site, I > > think, > > ^ The official NUT site? Feel free to post the URL. > > > and they said to set up USBD, so I did. Is that necessary for > > average
2013 Oct 16
2
Is UPSD necessary for average users?
On Tue, 15 Oct 2013 21:56:16 -0400 Charles Lepple <clepple at gmail.com> wrote: > >> What are you trying to optimize? > > > > nothing, but I just did not want another daemon running, or at > > least I do not want a port open that can access the UPS, because I > > will not be using it; it is more of a minor security issue than > > anything. The
2018 Mar 20
2
Best Power FE700VA?
On 03/19/2018 04:49 AM, Charles Lepple wrote: > The rc-style init systems typically want programs like the drivers to > go into the background on their own (as the driver does without "-D", > or when launched by "upsdrvctl start"). Other init systems like > launchd or systemd will monitor the PID of the program to restart it > if necessary, so they work best
2013 Nov 04
2
Is UPSD necessary for average users?
On Wed, 16 Oct 2013 08:19:11 +0100 Chris Boot <bootc at bootc.net> wrote: > >> > I forgot to mention: by default, NUT listens on localhost. If > >> > you are using Linux, you could add a "-m owner --uid-owner" rule > >> > to iptables to only match the UID for the NUT system user. > > > > Thanks; if it listens on localhost by default,
2018 Feb 19
2
Best Power FE700VA?
On 02/13/2018 03:49 AM, Charles Lepple wrote: > On Feb 12, 2018, at 11:53 PM, David Melik wrote: > > On 01/21/2018 05:53 AM, Charles Lepple wrote: >>> If you hook up a terminal emulator to the comms port (1200 baud, 8/N/1 unless stickers and/or configuration DIP switches indicate otherwise), and type "f" <return>, do you get a status line like one of the
2018 Feb 13
3
Best Power FE700VA?
On 01/21/2018 05:53 AM, Charles Lepple wrote: > My understanding was that many of the older Best Power units were downstream of generators, and as such, full-blown power outages of both mains and generator power were not expected. > > That said, it might be that the "bestfcom" driver predates when we were actively collecting specific model names for the Hardware Compatibility
2018 Mar 19
2
Best Power FE700VA?
On 02/20/2018 06:16 PM, Charles Lepple wrote: > Do you have a pinout for that cable? Unsure, but after recent suggestions, it may be working.? Already had NUT from SlackBuilds.org (SBo) installed, but reinstalled to add the group:user. > I forget if it is the default, but you might need to turn off the hardware and software flow control (minicom: Ctrl-A then letter O, "Serial port