CyberPower CST150UC: Question re: battery.runtime.low configuration settings
...?? ?Description:??? Debian GNU/Linux 12 (bookworm) ?? ?Release:??????? 12 ?? ?Codename:?????? bookworm exact NUT version: ?? ?Version: 2.8.0-7 NUT installation method: ?? ?apt install nut exact device name and related information: https://www.cyberpowersystems.com/product/ups/battery-backup/cst150uc/ ?? ?device.model: CST150UC ?? ?driver.version: 2.8.0 ?? ?driver.version.data: CyberPower HID 0.6 ?? ?driver.version.internal: 0.47 ?? ?driver.version.usb: libusb-1.0.26 (API: 0x1000109) ?? ?ups.vendorid: 0764 supported UPS variables (default values PRIOR to configuration change attempt) ?...
2024 Apr 24
1
CyberPower CST150UC: Question re: battery.runtime.low configuration settings
> On Apr 23, 2024, at 3:51?PM, tim.o via Nut-upsuser <nut-upsuser at alioth-lists.debian.net> wrote: > > The value changed to battery.runtime.low: 16, instead of 3600. I don't understand why, because executing the command resulted in SUCCESS. Unfortunately, the SUCCESS response is just saying that upsrw was able to send that request to upsd (i.e. the username/password were
2024 Apr 24
1
CyberPower CST150UC: Question re: battery.runtime.low configuration settings
...g this for me? When I initially issued 'upsrw' this is what was returned. What does the value '300' indicate, if not seconds; and attempting to change it to '3600' sets it two '16'. Is this what you mean when you're referring to a '8-bit field'? upsrw CST150UC ??? ??? ??? [battery.runtime.low] ?? ???? ??? Remaining battery runtime when UPS switches to LB (seconds) ?? ???? ??? Type: STRING ?? ???? ??? Maximum length: 10 ?? ???? ??? Value: 300 In my research I found that editing 'ups.conf' may allow to change the 'battery.runtime.low'...