Displaying 3 results from an estimated 3 matches for "cp1350".
Did you mean:
cp1250
2020 Oct 31
2
ups.test.result meaning
Hi folks, new to list...
nut 2.7.2 on Ubuntu 16.04 with Cyberpowersystems CP1350PFCLCD.
After performing upscmd cp1350 at localhost test.battery.start.quick the
result was "Done and warning". I searched through syslog but could find no
additional information.
What is the warning?
Battery charge was 100% before test was performed.
Here's the full output from ups...
2020 Oct 31
0
ups.test.result meaning
...since your test runtime of 305 is very close to the low limit of 300, that's the warning. Not yet a fail, but very, very close.
On October 31, 2020 11:41:39 AM CDT, Rick Dicaire <kritek at gmail.com> wrote:
>Hi folks, new to list...
>nut 2.7.2 on Ubuntu 16.04 with Cyberpowersystems CP1350PFCLCD.
>
>After performing upscmd cp1350 at localhost test.battery.start.quick the
>result was "Done and warning". I searched through syslog but could find no
>additional information.
>
>What is the warning?
>
>Battery charge was 100% before test was performed.
>...
2020 Nov 01
3
ups.test.result meaning
On Oct 31, 2020, at 8:30 PM, Gene Heskett <gheskett at shentel.net> wrote:
>
>> battery.voltage: 16.0
> At that voltage, 5 of the 12 cells are shorted
>> battery.voltage.nominal: 24
The 16.0 is a scaled version of the fixed (bogus) 24.0 V reading, similar to this unit:
https://networkupstools.org/ddl/Cyber_Power_Systems/CP1500PFCLCD.html
I think we even