2018 Jan 29
2
Centos 7 add-on serial cards
...m with 'setserial'? > Thanks for the suggestion. I looked at them with setserial, but I have no familiarity with the program to know what to change. setserial -ag /dev/ttyS* /dev/ttyS0, Line 0, UART: 16550A, Port: 0x03f8, IRQ: 4 ??? Baud_base: 115200, close_delay: 50, divisor: 0 ??? closing_wait: 3000 ??? Flags: spd_normal skip_test /dev/ttyS1, Line 1, UART: 16550A, Port: 0x8000, IRQ: 17 ??? Baud_base: 115200, close_delay: 50, divisor: 0 ??? closing_wait: none ??? Flags: spd_normal skip_test /dev/ttyS2, Line 2, UART: 16550A, Port: 0x8400, IRQ: 17 ??? Baud_base: 115200, close_delay:...
2018 Jan 29
0
Centos 7 add-on serial cards
...ks for the suggestion. > > I looked at them with setserial, but I have no familiarity with the > program to know what to change. > > setserial -ag /dev/ttyS* > /dev/ttyS0, Line 0, UART: 16550A, Port: 0x03f8, IRQ: 4 > ??? Baud_base: 115200, close_delay: 50, divisor: 0 > ??? closing_wait: 3000 > ??? Flags: spd_normal skip_test > > /dev/ttyS1, Line 1, UART: 16550A, Port: 0x8000, IRQ: 17 > ??? Baud_base: 115200, close_delay: 50, divisor: 0 > ??? closing_wait: none > ??? Flags: spd_normal skip_test > > /dev/ttyS2, Line 2, UART: 16550A, Port: 0x8400, IRQ: 17 &...
2018 Jan 28
2
Centos 7 add-on serial cards
I'm upgrading from CentOS6 to CentOS 7. I run 2 weather stations on C6 and have one of them attached to ttyS0 which is on the motherboard, and the other to ttyS2 which in on an add-on PCI serial card. I'm migrating the weather stations another host running C7 which has a similar hardware configuration.? When I connect the weather station to ttyS0 everything works fine, but when I try
2006 Jun 23
2
Need help configuring additional serial ports
...the "0xc000" and the IRQ on my system in the contents of /proc/pci. Here is what the built-in, working serial port looks like: # setserial -a /dev/ttyS0 /dev/ttyS0, Line 0, UART: 16550A, Port: 0x03f8, IRQ: 4 Baud_base: 115200, close_delay: 500, divisor: 0 closing_wait: 30000 Flags: spd_normal skip_test auto_irq Any ideas how to get these serial ports working? Thanks, Alfred # lspci 00:00.0 Host bridge: Intel Corporation 945G/GZ/P/PL Express Memory Controller Hub (rev 02) 00:02.0 VGA compatible controller: Intel Corporation 945G/GZ Express Integr...
2015 Nov 24
0
Cannot access Patriot Pro II from new system
..., you can connect the PC's TxD to RxD, and check that characters are echoed in minicom. Then check the continuity to the serial port. > > # setserial -gav /dev/ttyS0 > /dev/ttyS0, Line 0, UART: 16550A, Port: 0x03f8, IRQ: 4 > Baud_base: 115200, close_delay: 50, divisor: 0 > closing_wait: 3000 > Flags: spd_normal skip_test Curious about the "skip_test" option... > _______________________________________________ > Nut-upsuser mailing list > Nut-upsuser at lists.alioth.debian.org > http://lists.alioth.debian.org/cgi-bin/mailman/listinfo/nut-upsuser --...
2011 Nov 11
3
COPILOT Glucose Meter COM problem
I am a 62 year old beginner in Ubuntu. Thanks for any help, guidance, suggestions on this problem! I have used commands like the following to be certain that I have an active com port: dmesg | grep ttyS rm com1 ln -s /dev/ttyS0 com1 So I suspect the solution lies somewhere in WINE. If all else fails I will get a USB to SERIAL converter cable and try that. My wife has an Abbott Labs Freestyle
2015 Nov 23
2
Cannot access Patriot Pro II from new system
...ut 15233 Nov 23 14:04 upsmon.conf -rw-r----- 1 root nut 3887 M?r 20 2015 upssched.conf # ls -l /dev/ttyS0 crw-rw---- 1 root nut 4, 64 Nov 23 14:13 /dev/ttyS0 # setserial -gav /dev/ttyS0 /dev/ttyS0, Line 0, UART: 16550A, Port: 0x03f8, IRQ: 4 Baud_base: 115200, close_delay: 50, divisor: 0 closing_wait: 3000 Flags: spd_normal skip_test # stty -F /dev/ttyS0 speed 2400 baud; line = 0; min = 1; time = 0; -brkint -icrnl -imaxbel -opost -onlcr -isig -icanon -iexten -echo -echoe -echok -echoctl -echoke -------------- next part -------------- A non-text attachment was scrubbed... Name: signature.a...
2003 May 21
6
COM: port problems
Unfortunately, almost all the Windows programs I want to run under Wine need to access the COM: ports, and I cannot get any of them to run. Typically, I get stuff like this ... fixme:comm:EscapeCommFunction16 no cid=0 found! fixme:comm:EscapeCommFunction16 no cid=0 found! err:comm:COMM16_ReadComplete async read failed 000003e3 fixme:comm:EscapeCommFunction16 no cid=3 found!