search for: clockslips

Displaying 3 results from an estimated 3 matches for "clockslips".

2006 Feb 10
0
Vegastream clockslip problems
We have a Vegastream 400 connected to a digium Quad PRI card in an asterisk server, for the T.38 faxing here. Problem is that there are too many clockslips on it (and they get logged by asterisk as HDLC aborts). I've double checked the configuration on both sides, replaced the cable, tried different ports etc. It all lead to no resolution for it. Is there somebody on the list who has a Vegastream 400 working fine? Edwin -- Edwin Groothuis...
2006 Feb 12
2
dual TE410, both span 3 is broken
...i_cpe overlapdial=no channel => 187-201,203-217 And on them, both the span 3 interfaces gives huge amount of HDLC errors in the logging and clockslip-ticks on the line. Juggling the cables between other interfaces, and the then-non-span-3 is clear and the new-span-3 is full of HDLC errors and clockslips. Myself I'm going with a "this must be hardware problem", unless somebody else has an idea. Edwin -- Edwin Groothuis | Personal website: http://www.mavetju.org edwin@mavetju.org | Weblog: http://weblog.barnet.com.au/edwin/
2005 Jan 12
2
T1 Timing Slips
Does anyone know how to monitor * to see if they are receiving timing slips on a span connected to a T100P card? I am seeing b-channel restarts quite often and also getting "No D-channels available" warnings from time to time. Yesterday I had all the b-channels crash during a MeetMe Conference. Not good! This PRI is connected to an Avaya Definity PBX that is onsite and located in the