Samba 4.2.7 - winbind very high cpu load
...at /var/cache/samba/gencache.tdb Opening cache file at /var/cache/samba/gencache_notrans.tdb saf_fetch: failed to find server for "ALS2" domain connection_ok: Connection to (null) for domain ARRI is not connected saf_fetch: Returning "ADMUC1.arri.de" for "ARRI" domain check_negative_conn_cache returning result 0 for domain ARRI server ADMUC1.arri.de check_negative_conn_cache returning result 0 for domain ARRI server ADMUC1.arri.de sitename_fetch: Returning sitename for ARRI.DE: "MuenchenTuerkenstrasse" name ADMUC1.arri.de#20 found. Connecting to 192.168.100.100 at port 445 co...
2018 Apr 26
1
Failures to renegotiate machine password & domain participation check fails
...qdn" for "domain.fqdn" domain get_dc_list: preferred server list: "windc04.domain.fqdn, *" name domain.fqdn#1C found. Adding 3 DC's from auto lookup sitename_fetch: Returning sitename for realm 'domain.fqdn': "CAMPUS" name windc04.domain.fqdn#20 found. check_negative_conn_cache returning result 0 for domain domain.fqdn server 192.168.16.41 check_negative_conn_cache returning result 0 for domain domain.fqdn server 192.168.16.41 check_negative_conn_cache returning result 0 for domain domain.fqdn server 192.168.16.44 check_negative_conn_cache returning result 0 for domain do...
2016 Jun 06
2
Samba AD member lost domain join after reboot
Hello, After each reboot, my Samba AD member server lost domain join after reboot, I have to re-enter the server in the domain with the "net ads join -U administrator". I use version 4.4.3 of samba. The domain controller is a Samba AD server. After reboot, when I exectute "net ads testjoin" I have: kerberos_kinit_password SMB2$@AD.SAMDOM.LOCAL failed: failed
2016 Jun 07
2
Samba AD member lost domain join after reboot
...mon request 51 connection_ok: Connection to (null) for domain SAMDOM is not connected Opening cache file at /usr/local/samba/var/cache/gencache.tdb Opening cache file at /usr/local/samba/var/lock/gencache_notrans.tdb saf_fetch: Returning "dc2.ad.SAMDOM.local" for "SAMDOM" domain check_negative_conn_cache returning result 0 for domain SAMDOM server dc2.ad.SAMDOM.local check_negative_conn_cache returning result 0 for domain SAMDOM server dc2.ad.SAMDOM.local sitename_fetch: Returning sitename for AD.SAMDOM.LOCAL: "Default-First-Site-Name" name dc2.ad.SAMDOM.local#20 found. Connecting to 192....
2010 Jul 27
1
DNS update failed!
..., ad2" [2010/07/27 12:35:35, 5] libads/dns.c:817(sitename_fetch) sitename_fetch: Returning sitename for BUTB.BY: "Default-First-Site-Name" [2010/07/27 12:35:35, 5] libsmb/namecache.c:212(namecache_fetch) name ad.butb.by#20 found. [2010/07/27 12:35:35, 9] libsmb/conncache.c:150(check_negative_conn_cache) check_negative_conn_cache returning result 0 for domain BUTB.BY server 192.168.1.2 [2010/07/27 12:35:35, 5] libads/dns.c:817(sitename_fetch) sitename_fetch: Returning sitename for BUTB.BY: "Default-First-Site-Name" [2010/07/27 12:35:35, 5] libsmb/namecache.c:212(namecache_fetch)...
2019 Sep 10
4
Using net ads user to get child domain users on Samba 4.10.7
Hi all, I have an question about getting child domain users on Samba 4.10.7. 1. I have the command net ads search '(objectCategory=trustedDomain)' -P and already get the info below: objectClass: top objectClass: leaf objectClass: trustedDomain cn: hardware.qsan.ad.com distinguishedName: CN=hardware.qsan.ad.com,CN=System,DC=qsan,DC=ad,DC=com instanceType: 4 whenCreated: 20180611041431.0Z
2024 May 10
1
kinit failure
...icorn.com returned DNS code 3 dns_rr_srv_fill_done: async DNS A lookup for dc9.balewan.unicorn.com [0] got dc9.balewan.unicorn.com -> 192.168.50.17 dns_rr_srv_fill_done: async DNS AAAA lookup for dc9.balewan.unicorn.com [0] got dc9.balewan.unicorn.com -> fd8e:3a44:f7a7:d347:a00:27ff:fe9f:7dad check_negative_conn_cache returning result 0 for domain balewan.unicorn.com server 192.168.50.15 check_negative_conn_cache returning result 0 for domain balewan.unicorn.com server 192.168.50.17 check_negative_conn_cache returning result 0 for domain balewan.unicorn.com server fd8e:3a44:f7a7:d347:a00:27ff:fe9f:7dad get_dc_li...
2019 Sep 10
0
Using net ads user to get child domain users on Samba 4.10.7
...ame for realm 'QSAN.AD.COM': "Default-First-Site-Name" internal_resolve_name: looking up WIN-CLGRS20I3FM.hardware.qsan.ad.com#20 (sitename Default-First-Site-Name) name WIN-CLGRS20I3FM.hardware.qsan.ad.com#20 found. remove_duplicate_addrs2: looking for duplicate address/port pairs check_negative_conn_cache returning result -1073741823 for domain HARDWARE server 192.168.133.201 get_dc_list: negative entry WIN-CLGRS20I3FM.hardware.qsan.ad.com removed from DC list check_negative_conn_cache returning result -1073741823 for domain HARDWARE server 192.168.133.201 get_dc_list: negative entry 192.168.133.201...
2024 May 10
1
kinit failure
...de 3 dns_rr_srv_fill_done: > async DNS A lookup for dc9.balewan.unicorn.com [0] got > dc9.balewan.unicorn.com -> 192.168.50.17 dns_rr_srv_fill_done: async > DNS AAAA lookup for dc9.balewan.unicorn.com [0] got > dc9.balewan.unicorn.com -> fd8e:3a44:f7a7:d347:a00:27ff:fe9f:7dad > check_negative_conn_cache returning result 0 for domain > balewan.unicorn.com server 192.168.50.15 check_negative_conn_cache > returning result 0 for domain balewan.unicorn.com server > 192.168.50.17 check_negative_conn_cache returning result 0 for domain > balewan.unicorn.com server fd8e:3a44:f7a7:d347:a00:27ff...
2016 May 26
3
Failed to join domain: failed to lookup DC info for domain '<EXAMPLE.COM>' over rpc: The object name is not found.
...lt;example.com> [0, 100, 88] remove_duplicate_addrs2: looking for duplicate address/port pairs internal_resolve_name: returning 6 addresses: <hera_ipv6_#1>:88 <hera_ipv6_#2>:88 10.0.0.3:88 <zeus_ipv6_#1>:88 <zeus_ipv6_#2>:88 10.0.0.2:88 Adding 6 DC's from auto lookup check_negative_conn_cache returning result 0 for domain <EXAMPLE.COM> server <hera_ipv6_#1> check_negative_conn_cache returning result 0 for domain <EXAMPLE.COM> server <hera_ipv6_#2> check_negative_conn_cache returning result 0 for domain <EXAMPLE.COM> server 10.0.0.3 check_negative_conn_cache...
2019 Sep 11
1
Using net ads user to get child domain users on Samba 4.10.7
...': > "Default-First-Site-Name" > internal_resolve_name: looking up WIN-CLGRS20I3FM.hardware.qsan.ad.com#20 > (sitename Default-First-Site-Name) > name WIN-CLGRS20I3FM.hardware.qsan.ad.com#20 found. > remove_duplicate_addrs2: looking for duplicate address/port pairs > check_negative_conn_cache returning result -1073741823 for domain HARDWARE > server 192.168.133.201 > get_dc_list: negative entry WIN-CLGRS20I3FM.hardware.qsan.ad.com removed > from DC list > check_negative_conn_cache returning result -1073741823 for domain HARDWARE > server 192.168.133.201 > get_dc_list:...
2016 May 26
1
Failed to join domain: failed to lookup DC info for domain '<EXAMPLE.COM>' over rpc: The object name is not found.
...8] > remove_duplicate_addrs2: looking for duplicate address/port pairs > internal_resolve_name: returning 6 addresses: <hera_ipv6_#1>:88 > <hera_ipv6_#2>:88 10.0.0.3:88 <zeus_ipv6_#1>:88 <zeus_ipv6_#2>:88 > 10.0.0.2:88 > Adding 6 DC's from auto lookup > check_negative_conn_cache returning result 0 for domain <EXAMPLE.COM> > server <hera_ipv6_#1> > check_negative_conn_cache returning result 0 for domain <EXAMPLE.COM> > server <hera_ipv6_#2> > check_negative_conn_cache returning result 0 for domain <EXAMPLE.COM> > server 10.0.0.3...
2012 Oct 11
3
Joining Samba RODC, NT_STATUS_NOT_SUPPORTED
...st: "RODC14.TESTDOM.COM.TR, 10.10.25.4" sitename_fetch: Returning sitename for TESTDOM.COM.TR: "TEST" internal_resolve_name: looking up RODC14.TESTDOM.COM.TR#20 (sitename TEST) name RODC14.TESTDOM.COM.TR#20 found. remove_duplicate_addrs2: looking for duplicate address/port pairs check_negative_conn_cache returning result 0 for domain TESTDOM.COM.TR server 10.10.25.4 check_negative_conn_cache returning result 0 for domain TESTDOM.COM.TR server 10.10.25.4 remove_duplicate_addrs2: looking for duplicate address/port pairs get_dc_list: returning 1 ip addresses in an ordered list get_dc_list: 10.10.25.4:...
2014 Mar 24
0
Winbind logins failing after upgrade from Samba 3 to Samba 4
...er for "DOMAIN.LOCAL" domain get_dc_list: preferred server list: ", *" internal_resolve_name: looking up DOMAIN.LOCAL#1c (sitename (null)) name DOMAIN.LOCAL#1C found. remove_duplicate_addrs2: looking for duplicate address/port pairs Adding 2 DC's from auto lookup check_negative_conn_cache returning result 0 for domain DOMAIN.LOCAL server 10.235.202.197 check_negative_conn_cache returning result 0 for domain DOMAIN.LOCAL server 10.1.11.12 remove_duplicate_addrs2: looking for duplicate address/port pairs get_dc_list: returning 2 ip addresses in an ordered list get_dc_list: 10....
2015 Apr 17
2
Cannot join Ubuntu12.04 Samba 4.1.17 to domain
...9;s from auto lookup sitename_fetch: No stored sitename for DAN2003.SAMPLE.DOMAIN.COM internal_resolve_name: looking up SERVERDC1001.dan2003.sample.domain.com#20 (sitename (null)) name SERVERDC1001.dan2003.sample.domain.com#20 found. remove_duplicate_addrs2: looking for duplicate address/port pairs check_negative_conn_cache returning result 0 for domain dan2003.sample.domain.com server 10.80.8.88 check_negative_conn_cache returning result 0 for domain dan2003.sample.domain.com server 10.124.23.5 check_negative_conn_cache returning result 0 for domain dan2003.sample.domain.com server 10.184.32.187 check_negative_conn_c...
2015 Apr 17
0
Cannot join Ubuntu12.04 Samba 4.1.17 to domain
...name_fetch: No stored sitename for DAN2003.SAMPLE.DOMAIN.COM > internal_resolve_name: looking up SERVERDC1001.dan2003.sample.domain.com#20 > (sitename (null)) > name SERVERDC1001.dan2003.sample.domain.com#20 found. > remove_duplicate_addrs2: looking for duplicate address/port pairs > check_negative_conn_cache returning result 0 for domain > dan2003.sample.domain.com server 10.80.8.88 > check_negative_conn_cache returning result 0 for domain > dan2003.sample.domain.com server 10.124.23.5 > check_negative_conn_cache returning result 0 for domain > dan2003.sample.domain.com server 10.184.32....
2016 Oct 17
2
Bug 6870 resurfaced in Samba 4.2.10
...ver 1 (IPv6) could not be reached. To reiterate, this is in Samba 4.2.10, which ships with Debian 8 (Jessie), and occurs when running "net ads workgroup". This is the relevant section of the D10 log (compare with the strace from my previous email): Adding 2 DC's from auto lookup check_negative_conn_cache returning result 0 for domain FEDERATION.STARFLEET-NET.CO.UK server 192.168.81.132 check_negative_conn_cache returning result 0 for domain FEDERATION.STARFLEET-NET.CO.UK server 2001:8b0:1627:1::2 remove_duplicate_addrs2: looking for duplicate address/port pairs get_dc_list: returning 2 ip addresses...
2024 May 14
1
kinit failure
..._done: >> async DNS A lookup for dc9.balewan.unicorn.com [0] got >> dc9.balewan.unicorn.com -> 192.168.50.17 dns_rr_srv_fill_done: async >> DNS AAAA lookup for dc9.balewan.unicorn.com [0] got >> dc9.balewan.unicorn.com -> fd8e:3a44:f7a7:d347:a00:27ff:fe9f:7dad >> check_negative_conn_cache returning result 0 for domain >> balewan.unicorn.com server 192.168.50.15 check_negative_conn_cache >> returning result 0 for domain balewan.unicorn.com server >> 192.168.50.17 check_negative_conn_cache returning result 0 for domain >> balewan.unicorn.com server fd8e:3a44:f7...
2016 Oct 17
0
Bug 6870 resurfaced in Samba 4.2.10
...; To reiterate, this is in Samba 4.2.10, which ships with Debian 8 > (Jessie), and occurs when running "net ads workgroup". > > This is the relevant section of the D10 log (compare with the strace > from my previous email): > > Adding 2 DC's from auto lookup > check_negative_conn_cache returning result 0 for domain > FEDERATION.STARFLEET-NET.CO.UK server 192.168.81.132 > check_negative_conn_cache returning result 0 for domain > FEDERATION.STARFLEET-NET.CO.UK server 2001:8b0:1627:1::2 > remove_duplicate_addrs2: looking for duplicate address/port pairs > get_dc_list:...
2016 May 26
0
Failed to join domain: failed to lookup DC info for domain '<EXAMPLE.COM>' over rpc: The object name is not found.
...> [0, 100, 88]remove_duplicate_addrs2: looking for duplicate address/port pairsinternal_resolve_name: returning 6 addresses: <hera_ipv6_#1>:88 <hera_ipv6_#2>:88 10.0.0.3:88[7] <zeus_ipv6_#1>:88 <zeus_ipv6_#2>:88 10.0.0.2:88[8] EXAMPLE.COM[3]> server <hera_ipv6_#1>check_negative_conn_cache returning result 0 for domain <_EXAMPLE.COM_> server <hera_ipv6_#2>check_negative_conn_cache returning result 0 for domain <_EXAMPLE.COM_> server 10.0.0.3check_negative_conn_cache returning result 0 for domain <_EXAMPLE.COM_> server <zeus_ipv6_#1>check_negative_conn_ca...