2014 Mar 20
2
Unable to set up a "serial-over-USB" UPS (APC BZ2200BI-BR)
Dear NUT users/developers,
I'm having trouble while trying to configure the UPS APC BZ2200BI-BR[1] in NUT,
which despite having a USB cable it apparently communicates using the serial
protocol.
The relevant output of 'lsusb' is:
Bus 002 Device 004: ID 051d:c812 American Power Conversion
The device is registered as /dev/ttyACM0 and uses the kernel module 'cdc_acm'
(USB Abstract Control Model driver).
I've tried most of the listed APC compatible drivers [2] and they all failed.
I'm using NUT version 2.7.1. For instance, using 'usbhid-u...
2018 Oct 15
0
UPS BZ1500PBI-BR (Microsol - Brazil) Compatibility.
...te.
Please see that below:
root at DSAltaCloud:/usr/syno/etc/ups# upsdrvctl start
Network UPS Tools - UPS driver controller
DSM6-2-1-newmodel-repack-23796-180722
Network UPS Tools - Generic HID driver 0.38
(DSM6-2-1-newmodel-repack-23796-180722)
USB communication driver 0.32
This APC device (051d:c812) is not (or perhaps not yet) supported
by usbhid-ups. Please make sure you have an up-to-date version of NUT. If
this does not fix the problem, try running the driver with the
'-x productid=c812' option. Please report your results to the NUT user's
mailing list <nut-upsuser at lists....
2014 Jun 04
0
Unable to set up a "serial-over-USB" UPS (APC BZ2200BI-BR)
.../developers,
>
> I'm having trouble while trying to configure the UPS APC BZ2200BI-BR[1] in NUT,
> which despite having a USB cable it apparently communicates using the serial
> protocol.
>
> The relevant output of 'lsusb' is:
>
> Bus 002 Device 004: ID 051d:c812 American Power Conversion
Douglas,
It sounds like you have an UPS which was originally manufactured by Microsol.
http://forums.freenas.org/index.php?threads/nobreak-bz1200-br-back-ups-rs-1200va-600w-bivolt-115-nt.20247/
http://article.gmane.org/gmane.comp.monitoring.nut.devel/6685
Bruno...
2014 Jun 04
2
Unable to set up a "serial-over-USB" UPS (APC BZ2200BI-BR)
...trouble while trying to configure the UPS APC BZ2200BI-BR[1]
> in NUT,
> > which despite having a USB cable it apparently communicates using the
> serial
> > protocol.
> >
> > The relevant output of 'lsusb' is:
> >
> > Bus 002 Device 004: ID 051d:c812 American Power Conversion
>
>
> Douglas,
>
> It sounds like you have an UPS which was originally manufactured by
> Microsol.
>
>
> http://forums.freenas.org/index.php?threads/nobreak-bz1200-br-back-ups-rs-1200va-600w-bivolt-115-nt.20247/
>
> http://article.gmane....