search for: c812

Displaying 4 results from an estimated 4 matches for "c812".

Did you mean: 812
2014 Mar 20
2
Unable to set up a "serial-over-USB" UPS (APC BZ2200BI-BR)
Dear NUT users/developers, I'm having trouble while trying to configure the UPS APC BZ2200BI-BR[1] in NUT, which despite having a USB cable it apparently communicates using the serial protocol. The relevant output of 'lsusb' is: Bus 002 Device 004: ID 051d:c812 American Power Conversion The device is registered as /dev/ttyACM0 and uses the kernel module 'cdc_acm' (USB Abstract Control Model driver). I've tried most of the listed APC compatible drivers [2] and they all failed. I'm using NUT version 2.7.1. For instance, using 'usbhid-u...
2018 Oct 15
0
UPS BZ1500PBI-BR (Microsol - Brazil) Compatibility.
...te. Please see that below: root at DSAltaCloud:/usr/syno/etc/ups# upsdrvctl start Network UPS Tools - UPS driver controller DSM6-2-1-newmodel-repack-23796-180722 Network UPS Tools - Generic HID driver 0.38 (DSM6-2-1-newmodel-repack-23796-180722) USB communication driver 0.32 This APC device (051d:c812) is not (or perhaps not yet) supported by usbhid-ups. Please make sure you have an up-to-date version of NUT. If this does not fix the problem, try running the driver with the '-x productid=c812' option. Please report your results to the NUT user's mailing list <nut-upsuser at lists....
2014 Jun 04
0
Unable to set up a "serial-over-USB" UPS (APC BZ2200BI-BR)
.../developers, > > I'm having trouble while trying to configure the UPS APC BZ2200BI-BR[1] in NUT, > which despite having a USB cable it apparently communicates using the serial > protocol. > > The relevant output of 'lsusb' is: > > Bus 002 Device 004: ID 051d:c812 American Power Conversion Douglas, It sounds like you have an UPS which was originally manufactured by Microsol. http://forums.freenas.org/index.php?threads/nobreak-bz1200-br-back-ups-rs-1200va-600w-bivolt-115-nt.20247/ http://article.gmane.org/gmane.comp.monitoring.nut.devel/6685 Bruno...
2014 Jun 04
2
Unable to set up a "serial-over-USB" UPS (APC BZ2200BI-BR)
...trouble while trying to configure the UPS APC BZ2200BI-BR[1] > in NUT, > > which despite having a USB cable it apparently communicates using the > serial > > protocol. > > > > The relevant output of 'lsusb' is: > > > > Bus 002 Device 004: ID 051d:c812 American Power Conversion > > > Douglas, > > It sounds like you have an UPS which was originally manufactured by > Microsol. > > > http://forums.freenas.org/index.php?threads/nobreak-bz1200-br-back-ups-rs-1200va-600w-bivolt-115-nt.20247/ > > http://article.gmane....