search for: c1500

Displaying 3 results from an estimated 3 matches for "c1500".

Did you mean: 1500
2014 Nov 08
3
APC Smart-UPS C1500 connected by usb
Hi, I have setup NUT in netserver mode on debian wheezy with two APC UPS units connected to it by usb. lsusb identifies the units as Smart-UPS 1000 and Smart-UPS C1500. It appears these do not use the smart protocol and usbhid-ups is the correct driver to use. System: Debian wheezy with stock version of nut (Version: 2.6.4-2.3+deb7u1) Everything works rather well, except that the cgi-interface does not report input/output voltages and load for the C 1500 unit...
2014 Nov 10
1
APC Smart-UPS C1500 connected by usb
...; For the 1000, do the values match this page? > > > http://buildbot.networkupstools.org/~buildbot/cayman/docs/latest/ddl/APC/Smart-UPS_1000.html > > Yes it does (except that mine is a 120 V model, so input/output voltage is about 125) It doesn't look like we have an entry for a C1500 yet. Would you care to > submit the output of upsc, upsrw and upscmd -l? > Here it is $upscmd -l apc1500 Instant commands supported on UPS [apc1500]: beeper.disable - Disable the UPS beeper beeper.enable - Enable the UPS beeper beeper.mute - Temporarily mute the UPS beeper beeper.off - Obs...
2014 Nov 09
0
APC Smart-UPS C1500 connected by usb
...c also reports these values only for model 1000, not for 1500. Battery charge is and runtime are reported. For the 1000, do the values match this page? http://buildbot.networkupstools.org/~buildbot/cayman/docs/latest/ddl/APC/Smart-UPS_1000.html It doesn't look like we have an entry for a C1500 yet. Would you care to submit the output of upsc, upsrw and upscmd -l? > Is this a limitation of the driver, or is there way to get these data? The driver reports values with standard USB HID names. It is possible that your UPS reports these using different names, or does not expose them at al...