Displaying 5 results from an estimated 5 matches for "bx950mi".
Did you mean:
bx750mi
2024 Aug 20
1
APC BX ...MI series
Hi,
?Thank you for your prompt response!
The problem I had with my BX950MI unit was that it was frequently
reporting off-line, on batt and often not responding to requests from
apcupsd (apcaccess) and then going back online again. However, the
warranty replacement was prompted by a failed battery, apparently
leaking acid, after around ten months use.? As a matter of i...
2024 Aug 20
1
APC BX ...MI series
Peter Bell <peter at bellfamily.org.uk> writes:
> The problem I had with my BX950MI unit was that it was frequently
> reporting off-line, on batt and often not responding to requests from
> apcupsd (apcaccess) and then going back online again. However, the
> warranty replacement was prompted by a failed battery, apparently
> leaking acid, after around ten months use.?...
2024 Aug 19
1
APC BX ...MI series
...ent APC units, although I have three BackUPS CS650 units
> which have had very little issue..
>
> I've recently replaced the APC 1200 unit on my fileserver (running
> Slackware) with a CyberPower UPS and that appears to be well supported
> by NUT.
>
> However, I have an APC BX950MI unit which is currently being replaced
> under warranty. This unit has never worked well with apcupsd.
> I understand that changes have recently been incorporated into NUT to
> handle the BX units. I have installed NUT onto a Raspberry Pi, running
> PiOS (Bookworm), but NUT pulled fro...
2024 Aug 20
1
APC BX ...MI series
On 20/08/2024 19:18, Greg Troxel wrote:
> Peter Bell<peter at bellfamily.org.uk> writes:
>
>> The problem I had with my BX950MI unit was that it was frequently
>> reporting off-line, on batt and often not responding to requests from
>> apcupsd (apcaccess) and then going back online again. However, the
>> warranty replacement was prompted by a failed battery, apparently
>> leaking acid, after around t...
2024 Aug 19
1
APC BX ...MI series
...experiencing
issues with recent APC units, although I have three BackUPS CS650 units
which have had very little issue..
I've recently replaced the APC 1200 unit on my fileserver (running
Slackware) with a CyberPower UPS and that appears to be well supported
by NUT.
However, I have an APC BX950MI unit which is currently being replaced
under warranty.? This unit has never worked well with apcupsd.
I understand that changes have recently been incorporated into NUT to
handle the BX units.? I have installed NUT onto a Raspberry Pi, running
PiOS (Bookworm), but NUT pulled from the PiOS reposi...