Displaying 5 results from an estimated 5 matches for "bigups".
battery not installed, but battery still 100% and NUT 2.7.2-4 does not catch this and report a error
2017 Apr 04
2
battery not installed, but battery still 100% and NUT 2.7.2-4 does not catch this and report a error
...already provided by the AT declaration in upssched.conf. This would make
it possible to have messages and action specific to a UPS, in a multi-UPS
configuration.
I would like to be able to specify
NOTIFYMSG myups at localhost ONBATT "%s: local UPS on battery"
NOTIFYMSG bigups at server ONBATT "%s: Server room alert: UPS on battery"
NOTIFYFLAG myups at localhost ONBATT SYSLOG+EXEC+WALL
NOTIFYFLAG heartbeat at localhost ONBATT SYSLOG+EXEC
3. A <notify type> "ALARM" as you propose.
Best Regards, Roger
battery not installed, but battery still 100% and NUT 2.7.2-4 does not catch this and report a error
2017 Apr 04
0
battery not installed, but battery still 100% and NUT 2.7.2-4 does not catch this and report a error
...e AT declaration in upssched.conf. This would make it possible to
> have messages and action specific to a UPS, in a multi-UPS configuration.
>
> I would like to be able to specify
>
> NOTIFYMSG myups at localhost ONBATT "%s: local UPS on battery"
> NOTIFYMSG bigups at server ONBATT "%s: Server room alert: UPS on battery"
>
> NOTIFYFLAG myups at localhost ONBATT SYSLOG+EXEC+WALL
> NOTIFYFLAG heartbeat at localhost ONBATT SYSLOG+EXEC
>
> 3. A <notify type> "ALARM" as you propose.
good ideas
JonB
battery not installed, but battery still 100% and NUT 2.7.2-4 does not catch this and report a error
2017 Apr 03
2
battery not installed, but battery still 100% and NUT 2.7.2-4 does not catch this and report a error
On 04/03/2017 07:03 PM, Gene Heskett wrote:
>
> But it does that because you have tried to get 12 years out of a gell
> cell battery that is doing really really well if you get 4 years out of
> it. I am not saying you should do that _now_, without first replacing
> that thoroughly boiled dry battery, but as something you should set it
> up to do once you have a serviceable
battery not installed, but battery still 100% and NUT 2.7.2-4 does not catch this and report a error
2017 Apr 04
4
battery not installed, but battery still 100% and NUT 2.7.2-4 does not catch this and report a error
.... This would make it
>> possible to
>> have messages and action specific to a UPS, in a multi-UPS configuration.
>>
>> I would like to be able to specify
>>
>> NOTIFYMSG myups at localhost ONBATT "%s: local UPS on battery"
>> NOTIFYMSG bigups at server ONBATT "%s: Server room alert: UPS on
>> battery"
>>
>> NOTIFYFLAG myups at localhost ONBATT SYSLOG+EXEC+WALL
>> NOTIFYFLAG heartbeat at localhost ONBATT SYSLOG+EXEC
>>
>> 3. A <notify type> "ALARM" as you prop...
2006 Apr 17
40
Convince me to buy TextMate!
I got a Powerbook recently and am debating buying TextMate. I installed
the trial and have checked it out, but don''t see what''s so great about
it. AFAICS it''s the Ruby and Rails macros for expansion and other stuff
that might be it. Other than that, TextMate seems like a pretty basic
editor. I currently use PSPad and Editplus, and I could probably
get/make macros