NUT support for CyberPower PR1500LCDRTXL2Ua
On 2016-01-18 6:07 PM, Charles Lepple wrote: > [please use reply-all to include the list. thanks!] > > On Jan 18, 2016, at 5:08 PM, Ben Kamen <bkamen at benjammin.net> wrote: >> >> (is the USBHID worth using?) > > - - - > > Sounds like you are on the right track with the text protocol. There are two different sscanf() format strings - it looks like yours follows similar conventions ('I' for input voltage, 'O' for...
2013 Feb 01
1
Question for Dev's on NUT's upsstats.cgi
...m asking the dev's since I would guess it would need to start there.) I'm not sure if I'd call this a "bug" -- but let me know if I'm crazy. Thanks, -Ben -- Ben Kamen - O.D.T., S.P. ---------------------------------------------------------------------- eMail: ben at benjammin.net http://www.benjammin.net Fortune says: Insults are effective only where emotion is present. -- Spock, "Who Mourns for Adonais?" stardate 3468.1 - - NOTICE: All legal disclaimers sent to benjammin.net/...
2013 Feb 20
0
APC MeasureUPS support
...returning local temp/humidity for the cabled module just like they do for the SmartSlot card. > > So the question is "how to enable". Any suggestions? Thanks, -Ben -- Ben Kamen - O.D.T., S.P. ---------------------------------------------------------------------- eMail: ben at benjammin.net http://www.benjammin.net Fortune says: "Beauty is transitory." "Beauty survives." -- Spock and Kirk, "That Which Survives", stardate unknown - - NOTICE: All legal disclaimers sent...
2015 Apr 09
4
NUT and non-APCC UPSs doing calibration runs
I'm looking to buy some new UPSs and am thinking of parting ways with APC to explore other brands. Can anyone suggest another brand that handles doing calibration runs (or maybe another brand doesn't need them) that I can automate with NUT? Thanks, -Ben
2016 Jan 18
4
NUT support for CyberPower PR1500LCDRTXL2Ua
Hey all, I ended up picking up the module listed in Subject line. I switched over my config but apparently not all going smoothly. My config is: [office] driver = powerpanel port = /dev/ttyS0 desc = "Office UPS" When I test the driver running power-panel as a test, I get: > [root at cornelius init.d]# powerpanel -a office -D -D -D -D >
2015 Apr 10
0
NUT and non-APCC UPSs doing calibration runs
[please CC the list] On Apr 10, 2015, at 7:55 AM, Ben Kamen <bkamen at benjammin.net> wrote: > On 2015-04-09 9:48 PM, Charles Lepple wrote: >> On Apr 8, 2015, at 11:16 PM, Ben Kamen <bkamen at benjammin.net> wrote: >> >> As a starting point, you might want to search the NUT Device Dump Library (DDL) for 'test.battery' and 'test.interv...
2013 Sep 17
0
Support for APC Smart-UPS X 3000
Just my experiences speaking, look at another brand. I use MGE/Eaton and have had much better life and the quality has been much better. APC does not release the protocol for comunicating with the UPS and so to get NUT to work you have to sniff the traffic and then figure out what the commands and responses mean.(thus reverse engineered) APC also will change the protocol between models. (Thus why
2013 Sep 17
4
Support for APC Smart-UPS X 3000
Hi all, I am completely new to NUT and setting up a UPS shut down in Linux. I am looking at buying a APC Smart-UPS X 3000. When I look this device up in the compatibility list this specific model is not listed, only a generic entry for "Smart-UPS". It says to use the *apcsmart* driver. The legend shows this as "protocol based on reverse engineering". What does this
2015 Apr 10
0
NUT and non-APCC UPSs doing calibration runs
Don't choose mini-box OpenUPS. No instant commands. No reporting of power fail. No replies to emails to support. Otherwise perfect! I have mine working with support from Charles but not ideal. Regards, Philip. Sent from my iPhone > On 9 Apr 2015, at 05:16, Ben Kamen <bkamen at benjammin.net> wrote: > > I'm looking to buy some new UPSs and am thinking of parting ways with APC to explore other brands. > > Can anyone suggest another brand that handles doing calibration runs (or maybe another brand doesn't need them) that I can automate with NUT? > > Th...
2016 Jan 19
0
NUT support for CyberPower PR1500LCDRTXL2Ua
[please use reply-all to include the list. thanks!] On Jan 18, 2016, at 5:08 PM, Ben Kamen <bkamen at benjammin.net> wrote: > > (is the USBHID worth using?) It's hit-or-miss. I have a different CyberPower unit (no LCD, kind of like a big power strip) and there are some scale issues, similar to this entry: http://buildbot.networkupstools.org/~buildbot/docker-debian-jessie/docs/latest/ddl/Cy...
2017 Jun 11
0
Best way to shut down RH KVM/QEMU based VMs via NUT
...ows guests, but the linux guests work nicely with the default suspend. That said, I have only recently begun to see an issue with one of my CentOS7 guests being resumed with incorrect time--haven't gotten to the bottom of that one yet. --Larry On Thu, Jun 8, 2017 at 9:09 PM, Ben <bkamen at benjammin.net> wrote: > Hey there, > > Has anyone tackled the best way to shut down a VM running Win10 running > in RedHat's (CentOS 7) KVM/QEMU VM manager? > > I'm looking at this link to follow: > > > https://access.redhat.com/documentation/en-US/Red_Hat_ > Enterp...
2024 Apr 02
1
CyberPower PR3000LCDRTXL2U — battery date reset?
...il's advocate - if the battery swelled, it might hace leaked or fumed, contaminating the device and contacts. The safe approach (for their liability, and for end-users' fire hazard really) is to not claim the device is safe to use anymore. Jim On Tue, Apr 2, 2024, 07:11 Ben <bkamen at benjammin.net> wrote: > On 4/1/24 7:37 PM, Phil Stracchino via Nut-upsuser wrote: > > So, I just rebuilt the battery packs in my PR3000LCDRTXL2U and its > expansion unit. You don't want to KNOW. If the internal batteries have > overheated and bulged, you CANNOT remove the battery pac...
2014 Feb 12
2
Help with OpusEnc
...ced the number that's presented by 'opusenc' while recording and wondered how it knows that and of what it's representative. So, I'm going to crack into the docs -- but I thought I'd ask here in case anyone else has seen this phenomenon before. Thanks, -Ben -- ben at benjammin.net
2017 Jun 09
3
Best way to shut down RH KVM/QEMU based VMs via NUT
Hey there, Has anyone tackled the best way to shut down a VM running Win10 running in RedHat's (CentOS 7) KVM/QEMU VM manager? I'm looking at this link to follow:
2017 Jun 11
1
Best way to shut down RH KVM/QEMU based VMs via NUT
On 06/11/2017 07:00 AM, Larry Fahnoe wrote: > Hi Ben, > > On RHEL/CentOS 7, libvirt-guests (which comes from libvirt-client) on the host controls the suspend vs. shutdown behavior of the guests. By default the guests suspend, but if you want them to shutdown, change the ON_SHUTDOWN setting in /etc/sysconfig/libvirt-guests. I don't have any Windows guests, but the linux guests work
2013 Feb 28
8
false low battery alarm
Hi, I have two types of UPS devices and one of them (APC) gave me a false "low battery" alert. I can't reproduce the problem... Also, there was nothing apparently wrong with the UPS at the time of the false alert. All I could do was grab the driver values within a minute after the "low battery" notification. These are the values: battery.runtime.low : 120
2013 Nov 22
1
NUT-HAL (for use with USB UPS's and Gnome)
On 2013-11-20 6:20 PM, Charles Lepple wrote: > > No need to switch to serial if USB is working - there should be a nut-usb package or similar. You will probably have to remove nut-hal to install nut-usb. The nut+upsd+upsmon solution is mutually exclusive with nut-hal, but they use the same device-specific code, and it sounds like your device is compatible. What yum shows me is: (this is on
2017 Jun 11
0
Best way to shut down RH KVM/QEMU based VMs via NUT
On 06/11/2017 01:23 PM, julio valencia wrote: > > Stop emailing me > > You are on the nut-users mailing list. You need to unsubscribe if you want the list emails to stop. Cheers, -Ben
2013 Feb 18
1
APC Measure UPS support
Hey all, I have a measure-UPS card and the external cabled module. They're supposed to operate the same... does NUT auto detect them when using the apcsmart driver or are there config parms required? The the smart-slot unit is hooked to an SNMP/WEB card (and works through SNMP which isn't a fair compare) -- so I can't really test compare the two right now -- but I thought I'd
2014 Feb 18
1
Help with OpusEnc (SOLVED - sort of)
On 2014-02-12 12:11 PM, Ralph Giles wrote: > On 2014-02-11 8:27 PM, Ben wrote: > >> New to list and Opus Codec. > > Welcome1 > >> One of the things I've noticed while encoding is that Opus reports a float with an 'x' along with "realtime". > > This is intended to measure the cpu performance of the encoder. The > float is the number of