2006 Apr 14
3
Cyberpower 900AVR/BC900D newhidups problem
I'm trying to get nut to work with a Cyberpower 900AVR. There are many
different products known by this name, but this one has the extra name
'BC900D'.
I am told by a cyberpower tech that this one should talk exactly the
same USB protocol as the 685AVR, which was recently made to work with
newhidups.
Unfortunately, when I run the SVN checkout (trunk) of nut-2.1, I get:
sstreet drivers # ./newhidups -DDDDD -u root /dev/usb/hiddev0
Network...
2006 Jul 20
2
CyberPower CP1200AVR/BC1200D problems
...aw people
talking about problems so I'm guessing it may not be supported yet? I
did find some posts about people getting it to (sort of) work with some
hacks, but couldn't tell if they ever got submitted to the NUT
development team. I also found some posts about the CyberPower
900AVR/BC900D having issues, and it looks like I am having the same
problems as the person trying to use that UPS. Namely, I see these
messages in syslog:
kernel: usb 1-2: usbfs: USBDEVFS_CONTROL failed cmd newhidups rqt 128 rq
6 len 255 ret -110
I don't have much experience in protocol decoding, but I...
2014 Aug 11
1
Cyberpower Value1200E might not need 0.667 battery scaling
...eck = 1.4;
>
> static void *cps_battery_scale(USBDevice_t *device)
> {
> - battery_scale = 0.667;
> + might_need_battery_scale = 1;
> return NULL;
> }
>
> /* USB IDs device table */
> static usb_device_id_t cps_usb_device_table[] = {
> - /* 900AVR/BC900D, CP1200AVR/BC1200D */
> + /* 900AVR/BC900D */
> { USB_DEVICE(CPS_VENDORID, 0x0005), NULL },
> - /* Dynex DX-800U? */
> + /* Dynex DX-800U?, CP1200AVR/BC1200D, CP825AVR-G, CP1000AVRLCD, CP1000PFCLCD, CP1500C, CP550HG, etc. */
> { USB_DEVICE(CPS_VENDORID, 0x0501), &cps_batter...
2014 Aug 09
0
Cyberpower Value1200E might not need 0.667 battery scaling
On Aug 8, 2014, at 9:15 AM, Charles Lepple <clepple at gmail.com> wrote:
> On Aug 7, 2014, at 10:52 PM, Charles Lepple <clepple at gmail.com> wrote:
>
>> On Aug 7, 2014, at 10:18 PM, Matthew Stapleton <matthew4196 at gmail.com> wrote:
>>
>>> I just got a Cyberpower SOHO Value 1200 ELCD UPS and even with nut 2.7.2, it appears to report battery voltage
2014 Aug 08
2
Cyberpower Value1200E might not need 0.667 battery scaling
On Aug 7, 2014, at 10:52 PM, Charles Lepple <clepple at gmail.com> wrote:
> On Aug 7, 2014, at 10:18 PM, Matthew Stapleton <matthew4196 at gmail.com> wrote:
>
>> I just got a Cyberpower SOHO Value 1200 ELCD UPS and even with nut 2.7.2, it appears to report battery voltage too low due to the battery scaling function (In drivers/cps-hid.c). Even though the ups has usb id: