search for: baud

Displaying 20 results from an estimated 281 matches for "baud".

Did you mean: bad
2000 Nov 22
3
2.3.0p1: terminal baud rate is 300
When using OpenSSH 2.3.0p1 on HP-UX 11.00 the terminal's baud rate is 300, causing non-desired effects in vi and Emacs: vi only shows a few lines, and Emacs adds a huge delay after each line of output. When connecting via TELNET, I get at least 9600 baud. Should the login procedure mess with the baud rate? Regards, Ulrich P.S. I'm not subscribed to t...
2002 Aug 05
0
printing to windows with cups
...libc.so.6 => /lib/libc.so.6 (0x40186000) libdl.so.2 => /lib/libdl.so.2 (0x402ad000) /lib/ld-linux.so.2 => /lib/ld-linux.so.2 (0x40000000) then ok. lpinfo -v gives: network socket network http network ipp network lpd direct parallel:/dev/lp0 direct scsi serial serial:/dev/ttyS0?baud=115200 serial serial:/dev/ttyS1?baud=115200 serial serial:/dev/ttyS2?baud=115200 serial serial:/dev/ttyS3?baud=115200 serial serial:/dev/ttyS4?baud=115200 serial serial:/dev/ttyS5?baud=115200 serial serial:/dev/ttyS6?baud=115200 ----------------------------------------------- serial serial:/dev/tty...
2016 Apr 18
8
[Bug 2565] New: High baud rate gets sent, solaris closes pty
https://bugzilla.mindrot.org/show_bug.cgi?id=2565 Bug ID: 2565 Summary: High baud rate gets sent, solaris closes pty Product: Portable OpenSSH Version: 7.1p2 Hardware: Sparc OS: Solaris Status: NEW Severity: minor Priority: P5 Component: sshd Assignee: unassigned-bugs at mindrot.or...
2011 Mar 31
0
reliance netconnect as on a Linux system ( centos5.5 ) Modem not responding.
...eneric 7-2:1.0: generic converter detected usb 7-2: generic converter now attached to ttyUSB0 usbcore: registered new driver usbserial_generic drivers/usb/serial/usb-serial.c: USB Serial Driver core i edit the vi /etc/wvdial.conf with the following content [Dialer Defaults] Modem = /dev/ttyUSB0 Baud = 57600 Setvolume = 0 Dial-AT-OK ATDT Command = Init1 = ZTE FlowControl = Hardware (CRTSCTS) Phone = #777 Username = 7228412233 Password = 7228412233 New PPPD = yes Carrier Check = no Stupid Mode = yes wen i try to detect the modem it gives me a failure wvdialconf /etc/wvdial.conf ::::::: Scann...
2000 Nov 16
0
HP-UX 11.00: baudrate set to 300 Baud
Hello, GNU Emacs suffers from poor performance because the baud rate in HP-UX 11.00 is set to 300 baud when connecting via OpenSSH 2.1.1p1. Can anybody tell why? Maybe ssh should modify some termio bits when logging in? Regards, Ulrich
2009 Jul 06
3
Smart-UPS RT 3000 Baud Rate
...using nut successfully over the 940-0095B cable for a couple of years. I have just received a second unit, but it is slightly different in 3 ways that I have found so far. 1. It's a Smart-UPS RT 3000 XL 2. The 940-0095B cable now uses an RJ45 connector at the UPS end. 3. It now requires a baud rate of 9600 instead of the 2400 used previously. Can anyone tell me if modifying drivers/apcsmart.c void upsdrv_initups(void) { char *cable; upsfd = ser_open(device_path); ser_set_speed(upsfd, device_path, B2400); to void upsdrv_initups(void) { char *cable; upsfd = ser_open(device_path)...
2008 May 27
1
USB modem on centos
...rnal modems and had no issues. One this unit I plugged it in, dmesg says its recogized. I did "ln -s /dev/ttyACM0 /dev/ttyS4" this works. I then did "cu -l /dev/ttyS4" type "AT" and I get OK... looking good. When I "ATDT my number" I get a connection at 1200 baud (which I should) and funny characters... I thought looks like a parity thing. I then did "cu -e -l /dev/ttyS4" type "AT" and I get OK... Now when I do "ATDT my number" I get a connection at 1200 baud and I get readable characters. In the past internal PCI modems I nev...
2014 Jul 14
1
Cemtos 6 - rc.local does not run
Is there a special step for this? -- Cosme Corr?a On Jul 8, 2014 4:32 PM, <m.roth at 5-cent.us> wrote: > Always Learning wrote: > > > > On Tue, 2014-07-08 at 11:10 -0700, John R Pierce wrote: > >> On 7/8/2014 10:36 AM, Always Learning wrote: > >> > 75 baud on a TTY (clank, clank, clank, ding, thud as the printer head > >> > returned to the beginning of the line) and an amazingly fast speed of > >> > 300 baud on the up-market Terminet (? spelling). > >> > > >> > Perhaps the speeds were 300 and 1,200 baud...
2005 Oct 19
4
Cyberpower CP550SL/AE550 Serial
...if it uses the same or similar protocol as the other Cyberpower models? I have an HP 4952A Serial Protocol Analyzer and a Cyberpower CP550SL. Once I get the CP550SL up and working in Windows over RS232 I'll hook up the 4952A and see whats going on. I'm not sure what it uses for default baud rate. The 4952A is limited to 38400. Is anyone interested in any information I might gather from it? Suggestions as to which if any driver I should start from would be appriciated. Ideally I'd like to add support to the cyberpower driver as patch if its at all similar to that protocol. Thi...
2001 Mar 28
1
Want to create a DOS network boot disk
...ver, I get rejected for what I have to assume is password problems. The clipped a piece of the log file here: [2001/03/27 17:38:32, 3] smbd/process.c:switch_message(448) switch message SMBsesssetupX (pid 2349) [2001/03/27 17:38:32, 3] smbd/reply.c:reply_sesssetup_and_X(809) sesssetupX:name=[BAUDE] [2001/03/27 17:38:32, 0] smbd/password.c:password_ok(546) Error: challenge not done for user=baude [2001/03/27 17:38:32, 1] smbd/reply.c:reply_sesssetup_and_X(925) Rejecting user 'baude': authentication failed [2001/03/27 17:38:32, 3] smbd/error.c:error_packet(138) error packet at l...
2006 Apr 07
1
Formatting form tags for children of parrent data?
...t; <p><b>Misc (extended Description)</b><br> <textarea id="program_misc" name="archive[misc]" cols="40" rows="20" wrap="virtual" ><%= @program.misc %></textarea> </p> <p><b>Baud</b><br> <select id="program_baud" name="archive[baud]"> <% [''2000'',''300'',''2000 BlueRam''].each do |baud| -%> <option <%= ''selected'' if @program.baud == baud %>><%=...
2013 May 24
10
[PATCH 0/4] ARM/early-printk: Improve reusability and add Calxeda support
...its to add support the Calxeda Midway hardware. This haven''t been extensively tested, but I looked at the generated assembly and did some quick checks on Versatile Express. Signed-off-by: Andre Przywara <andre.przywara@calxeda.com> Andre Przywara (4): arm/early-printk: calculate baud rate divisor from user provided value arm/early-printk: allow skipping of UART init arm/early-printk: move UART base address to Rules.mk arm/early-printk: add Calxeda Midway UART support xen/arch/arm/Rules.mk | 13 +++++++++++++ xen/arch/arm/arm32/debug-exynos4210.inc...
2006 Dec 13
3
send fax by Iaxmodem ?
....12: [13725]: --> [11:NO DIALTONE] d?c 13 13:47:21.12: [13725]: SEND FAILED: JOB 2 DEST 0426690268 ERR No local dialtone d?c 13 13:47:21.12: [13725]: <-- [5:ATH0\r] d?c 13 13:47:21.12: [13725]: --> [2:OK] d?c 13 13:47:21.12: [13725]: MODEM set DTR OFF d?c 13 13:47:21.12: [13725]: MODEM set baud rate: 0 baud (flow control unchanged) d?c 13 13:47:21.12: [13725]: STATE CHANGE: SENDING -> MODEMWAIT (timeout 5) d?c 13 13:47:21.12: [13725]: SESSION END Thanks bye
2011 Jul 02
2
Losing serial console boot output / sync_console
Hello, About two months ago I sent this email to the Xen users lists regarding a problem I was having losing some of my serial console output on boot: http://lists.xensource.com/archives/html/xen-users/2011-04/msg00340.html Unfortunately it got no replies. I was just wondering and hoping if any developers could answer the following questions: - Should I open a bug regarding the loss of serial
2008 Jan 14
10
Using EventMachine to listen from non-network
...uilliame Pierronnet''s Ruby/SerialPort library. It turned out to be simpler than I thought it would be: require ''serialport'' $eventmachine_library = :pure_ruby require ''eventmachine'' module EventMachine class << self def connect_serial(dev, baud, databits, stopbits, parity) EvmaSerialPort.open(dev, baud, databits, stopbits, parity).uuid end end def EventMachine::open_serial(dev, baud, databits, stopbits, parity, handler=nil) klass = if (handler and handler.is_a?(Class)) handl...
2002 Nov 04
1
[R] CTRL-C suspends echo of shell (R versions 1.6.0 and 1.6.1) (PR#2253)
Problem: - Shell does not echo anymore after using CTRL-C (to interrupt calculations) once during a R session. Procedure: - [start session] R - [input] CTRL-C - [end session] q() Some details: - `stty` before: speed 38400 baud; line = 0; lnext = <undef>; - `stty` after: speed 38400 baud; line = 0; lnext = <undef>; min = 1; time = 0; -icrnl -icanon -echo I have seen the problem in versions 1.6.0 and 1.6.1, but not in 1.5.1 which I am running on SuSE Linux 7.3. The shell used is bash-2.05.0(1). Wolf...
2020 Oct 07
0
dbus issue on centos 7 as a lxc container
...-v01 at openssh.com,ssh-rsa,ssh-rsa-cert-v01 at openssh.com -oCASignatureAlgorith ms=rsa-sha2-256,ecdsa-sha2-nistp256,ecdsa-sha2-nistp384,rsa-sha2-512,ecdsa-sha2-nistp521,ssh-ed25519,ssh-rsa root 45 0.0 0.0 6520 660 pts/3 Ss+ Oct06 0:00 /sbin/agetty -o -p -- \u --noclear --keep-baud pts/3 115200,38400,9600 vt220 root 46 0.0 0.0 6520 724 pts/2 Ss+ Oct06 0:00 /sbin/agetty -o -p -- \u --noclear --keep-baud pts/2 115200,38400,9600 vt220 root 47 0.0 0.0 22868 1848 ? Ss Oct06 0:00 /usr/sbin/crond -n root 48 0.0 0.0 6520 664...
2004 Feb 12
1
Porting let* from Common LISP to R
...evaluate the initialization of its local variables in sequentially nested scopes, i.e. it provides an order to the binding and visibility of preceding variables.". I have included the recursive Common LISP function in which let* block appears and a straighforward R port. Thank you, Gabriel Baud-Bovy The let* block appears in the following LISP function: (defun infer (goal subsitution kb) (if(null kb) (make-empty-stream) (let* ((assertion (rename-variable (car kb))) ; ********* (match ([...]))) (if (equal match 'failed) (infer goa...
2002 Sep 17
1
'error in rsync protocol data stream'
...s, symlinks, batchfiles, IPv6, 64-bit system inums, 64-bit internal inums What's the problem? Should I upgrade rsync? -- __Pascal_Bourguignon__ http://www.informatimago.com/ ---------------------------------------------------------------------- The name is Baud,...... James Baud.
2009 Aug 21
1
problem with asterisk hylafax and sangoma A200D
...cted Aug 20 16:11:22 voz FaxQueuer[3504]: NOTIFY: bin/notify "sendq/q7" "requeued" "" "16:16" Aug 20 16:11:23 voz FaxQueuer[3504]: NOTIFY exit status: 0 (6721) Aug 20 16:11:30 voz FaxGetty[3666]: MODEM set DTR OFF Aug 20 16:11:30 voz FaxGetty[3666]: MODEM set baud rate: 0 baud (flow control unchanged) Aug 20 16:11:30 voz FaxGetty[3666]: DELAY 75 ms Aug 20 16:11:30 voz FaxGetty[3666]: MODEM set DTR ON Aug 20 16:11:30 voz FaxGetty[3666]: DELAY 2600 ms Aug 20 16:11:34 voz FaxGetty[3666]: MODEM set baud rate: 19200 baud, input flow XON/XOFF, output faxstat -d H...