2016 Apr 15
11
[PATCH 1/2] nouveau/bl: Assign different names to interfaces
Currently, every backlight interface created by Nouveau uses the same name,
nv_backlight. This leads to a sysfs warning as it tries to create an already
existing folder. This patch adds a incremented number to the name, but keeps
the initial name as nv_backlight, to avoid possibly breaking userspace; the
second interface will be named nv_backlight1, and so on.
Fixes: fdo#86539
Signed-off-by:
2016 Apr 15
0
[PATCH 1/2] nouveau/bl: Assign different names to interfaces
On Fri, Apr 15, 2016 at 10:57 AM, Pierre Moreau <pierre.morrow at free.fr> wrote:
> Currently, every backlight interface created by Nouveau uses the same name,
> nv_backlight. This leads to a sysfs warning as it tries to create an already
> existing folder. This patch adds a incremented number to the name, but keeps
> the initial name as nv_backlight, to avoid possibly breaking
2016 Nov 13
1
[PATCH v3 1/2] nouveau/bl: Assign different names to interfaces
From: Pierre Moreau <pierre.morrow at free.fr>
Currently, every backlight interface created by Nouveau uses the same name,
nv_backlight. This leads to a sysfs warning as it tries to create an already
existing folder. This patch adds a incremented number to the name, but keeps
the initial name as nv_backlight, to avoid possibly breaking userspace; the
second interface will be named
2016 Apr 17
0
[PATCH v2 1/2] nouveau/bl: Assign different names to interfaces
Currently, every backlight interface created by Nouveau uses the same name,
nv_backlight. This leads to a sysfs warning as it tries to create an already
existing folder. This patch adds a incremented number to the name, but keeps
the initial name as nv_backlight, to avoid possibly breaking userspace; the
second interface will be named nv_backlight1, and so on.
Bugzilla:
2016 Dec 07
0
[PATCH v4 1/2] nouveau/bl: Assign different names to interfaces
Currently, every backlight interface created by Nouveau uses the same name,
nv_backlight. This leads to a sysfs warning as it tries to create an already
existing folder. This patch adds a incremented number to the name, but keeps
the initial name as nv_backlight, to avoid possibly breaking userspace; the
second interface will be named nv_backlight1, and so on.
Bugzilla:
2024 Feb 13
2
[PATCH v2 3/8] fbdev: Do not include <linux/backlight.h> in header
Forward declare struct backlight_device and remove the include
statement.
Signed-off-by: Thomas Zimmermann <tzimmermann at suse.de>
Reviewed-by: Jani Nikula <jani.nikula at intel.com>
---
include/linux/fb.h | 2 +-
1 file changed, 1 insertion(+), 1 deletion(-)
diff --git a/include/linux/fb.h b/include/linux/fb.h
index 2ce2f5c2fca9a..7380d959c5d53 100644
--- a/include/linux/fb.h
+++
2016 Nov 14
0
[PATCH v3 1/2] nouveau/bl: Assign different names to interfaces
On Sun, Nov 13, 2016 at 08:57:06PM +0100, Pierre Moreau wrote:
> From: Pierre Moreau <pierre.morrow at free.fr>
>
> Currently, every backlight interface created by Nouveau uses the same name,
> nv_backlight. This leads to a sysfs warning as it tries to create an already
> existing folder. This patch adds a incremented number to the name, but keeps
> the initial name as
2018 Aug 29
5
[PATCH v2 0/5] drm/nouveau: Backlight fixes and cleanup
Next version of https://patchwork.freedesktop.org/series/48596/ . Made
some important changes to the refactoring patch, but everything else is
the same.
Lyude Paul (5):
drm/nouveau: Check backlight IDs are >= 0, not > 0
drm/nouveau: Move backlight device into nouveau_connector
drm/nouveau: s/nouveau_backlight_exit/nouveau_backlight_fini/
drm/nouveau: Cleanup indenting in
2018 Aug 23
6
[PATCH 0/5] drm/nouveau: Backlight fixes and cleanup
This series fixes some issues with nouveau's backlight support that were
causing kernel panics on module reloads, specifically on systems with
nouveau handling the backlight of one of the displays.
While we're at it, let's cleanup nouveau_backlight.c as well
Lyude Paul (5):
drm/nouveau: Check backlight IDs are >= 0, not > 0
drm/nouveau: Move backlight device into
2018 Aug 29
5
[PATCH v3 0/5] drm/nouveau: Backlight fixes and cleanup
Next version of https://patchwork.freedesktop.org/series/48596/ . Added
NV_INFO_ONCE and made "Move backlight device into nouveau_connector" use
that instead so we don't print the GMUX warning more then once.
Lyude Paul (5):
drm/nouveau: Add NV_PRINTK_ONCE and variants
drm/nouveau: Move backlight device into nouveau_connector
drm/nouveau:
2016 Apr 15
2
[PATCH 1/2] nouveau/bl: Assign different names to interfaces
On 11:06 AM - Apr 15 2016, Ilia Mirkin wrote:
> On Fri, Apr 15, 2016 at 10:57 AM, Pierre Moreau <pierre.morrow at free.fr> wrote:
> > Currently, every backlight interface created by Nouveau uses the same name,
> > nv_backlight. This leads to a sysfs warning as it tries to create an already
> > existing folder. This patch adds a incremented number to the name, but keeps
2018 Aug 29
6
[PATCH RESEND v3 0/6] drm/nouveau: Backlight fixes and cleanup
Forgot to send 6 patches instead of five since there's one new one now,
whoops!
No actual changes, next version of
https://patchwork.freedesktop.org/series/48596/
Lyude Paul (6):
drm/nouveau: Check backlight IDs are >= 0, not > 0
drm/nouveau: Add NV_PRINTK_ONCE and variants
drm/nouveau: Move backlight device into nouveau_connector
drm/nouveau:
2018 Sep 06
7
[PATCH v4 0/6] Backlight fixes and cleanup
Refactor for Ben, hopefully this time this should apply to his tree.
Next version of https://patchwork.freedesktop.org/series/48596/
No changes otherwise.
Lyude Paul (6):
drm/nouveau: Check backlight IDs are >= 0, not > 0
drm/nouveau: Add NV_PRINTK_ONCE and variants
drm/nouveau: Move backlight device into nouveau_connector
drm/nouveau:
2018 Jul 05
4
[PATCH 0/2] drm/nouveau: Fix panic on nouveau unload.
If have a couple patches I found while looking at a panic
I was seeing while unloading the nouveau module.
Unloading the nouveau module on my optimus notebook machine causes
the system to panic. This started occuring when moving from 4.4
to 4.14.
These patches make it such that the system does not panic
when unloading the module.
4.14 also requires commit 34112bf4935d ("drm/nouveau/fbcon:
2016 Aug 04
2
[Intel-gfx] [PATCH] backlight: Avoid double fbcon backlight handling
On Tue, 12 Jul 2016, Daniel Vetter <daniel at ffwll.ch> wrote:
> On Thu, Jun 30, 2016 at 12:30:56PM +0100, Chris Wilson wrote:
>> Backlights controlled by i915.ko and only associated with its connectors
>> and also only associated with the intel_drmfb fbcon, controlled by
>> i915.ko. In this situation, we already handle adjusting the backlight
>> when the fbcon is
2016 Jul 12
0
[Intel-gfx] [PATCH] backlight: Avoid double fbcon backlight handling
On Thu, Jun 30, 2016 at 12:30:56PM +0100, Chris Wilson wrote:
> Backlights controlled by i915.ko and only associated with its connectors
> and also only associated with the intel_drmfb fbcon, controlled by
> i915.ko. In this situation, we already handle adjusting the backlight
> when the fbcon is blanked/unblanked and do not require backlight trying
> to do the same.
>
>
2016 Jun 30
6
[PATCH] backlight: Avoid double fbcon backlight handling
Backlights controlled by i915.ko and only associated with its connectors
and also only associated with the intel_drmfb fbcon, controlled by
i915.ko. In this situation, we already handle adjusting the backlight
when the fbcon is blanked/unblanked and do not require backlight trying
to do the same.
Attempting to register with the fbdev as a client causes lockdep to warn
about a dependency cycle:
[
2016 Aug 04
1
[Intel-gfx] [PATCH] backlight: Avoid double fbcon backlight handling
On Thu, Aug 04, 2016 at 12:02:23PM +0300, Jani Nikula wrote:
> On Tue, 12 Jul 2016, Daniel Vetter <daniel at ffwll.ch> wrote:
> > On Thu, Jun 30, 2016 at 12:30:56PM +0100, Chris Wilson wrote:
> >> Backlights controlled by i915.ko and only associated with its connectors
> >> and also only associated with the intel_drmfb fbcon, controlled by
> >> i915.ko. In
2010 Oct 26
22
[Bug 31122] New: Cannot control backlight intensity on Powerbook
https://bugs.freedesktop.org/show_bug.cgi?id=31122
Summary: Cannot control backlight intensity on Powerbook
Product: xorg
Version: unspecified
Platform: PowerPC
OS/Version: Linux (All)
Status: NEW
Severity: enhancement
Priority: medium
Component: Driver/nouveau
AssignedTo: nouveau at
2012 Nov 19
2
[PATCH 158/493] video: remove use of __devinit
CONFIG_HOTPLUG is going away as an option so __devinit is no longer
needed.
Signed-off-by: Bill Pemberton <wfp5p at virginia.edu>
Cc: Florian Tobias Schandinat <FlorianSchandinat at gmx.de>
Cc: Jaya Kumar <jayalk at intworks.biz>
Cc: Paul Mackerras <paulus at samba.org>
Cc: Benjamin Herrenschmidt <benh at kernel.crashing.org>
Cc: Russell King <linux at