search for: b2cb5771

Displaying 2 results from an estimated 2 matches for "b2cb5771".

2017 Jun 27
0
Help with Elite 800VA usb UPS
...do you see CAL in the status > string during a battery test? If not, your UPS is not reporting this the > way that the driver expects. -------------- next part -------------- An HTML attachment was scrubbed... URL: <http://lists.alioth.debian.org/pipermail/nut-upsuser/attachments/20170627/b2cb5771/attachment.html>
2017 Jun 27
2
Help with Elite 800VA usb UPS
On Jun 26, 2017, at 7:03 AM, Andrea de Lutti <adelutti at gmail.com> wrote: > > Are there no warnings for battery test? not sure if you saw my reply on 2016-06-17: Do you mean a notification that a test is in progress, or something for the results? There is the REPLBATT message in upsmon when the battery test fails, but I don't think the generic Qx protocol supports the RB