Displaying 12 results from an estimated 12 matches for "apcstatusflag".
2020 Sep 03
2
UPS reboots with APC UPS
...ReportID:
0x06, Offset: 0, Size: 8, Value: 0
0.569498 Path: UPS.PowerSummary.Discharging, Type: Input, ReportID:
0x06, Offset: 8, Size: 8, Value: 0
0.569517 Path: UPS.PowerSummary.Discharging, Type: Feature, ReportID:
0x06, Offset: 8, Size: 8, Value: 0
0.569534 Path: UPS.PowerSummary.APCStatusFlag, Type: Input, ReportID:
0x06, Offset: 16, Size: 8, Value: 8
0.569548 Path: UPS.PowerSummary.APCStatusFlag, Type: Feature,
ReportID: 0x06, Offset: 16, Size: 8, Value: 8
0.572386 Path: UPS.PowerSummary.ManufacturerDate, Type: Feature,
ReportID: 0x07, Offset: 0, Size: 16, Value: 19270
0...
2005 Aug 02
0
newhidups for APC Back-UPS ES 650
...A1 00 85 01 09 FE 79 01
Detected an UPS: APC/Back-UPS ES 650 FW:818.w1.D USB FW:w1
............. output heavily reduced!
Path: UPS.PowerSummary.iSerialNumber
Path: UPS.PowerSummary.iDeviceChemistry
Path: UPS.PowerSummary.iOEMInformation
Path: UPS.PowerSummary.Rechargeable
Path: UPS.PowerSummary.APCStatusFlag
Path: UPS.PowerSummary.APCStatusFlag
Path: UPS.PowerSummary.ManufacturerDate
Path: UPS.PowerSummary.ConfigVoltage
Path: UPS.PowerSummary.Voltage
Path: UPS.PowerSummary.iManufacturer
Path: UPS.PowerSummary.CapacityMode
Path: UPS.PowerSummary.RemainingCapacity
Path: UPS.PowerSummary.RemainingCapacity...
2008 Oct 16
2
usbhid-ups works, upsc doesn't - help?
...eportID: 0x06,
Offset: 8, Size: 8, Value: 0.000000
Path: UPS.PowerSummary.ACPresent, Type: Feature, ReportID: 0x13,
Offset: 0, Size: 8, Value: 1.000000
Path: UPS.PowerSummary.BelowRemainingCapacityLimit, Type: Feature,
ReportID: 0x14, Offset: 0, Size: 8, Value: 0.000000
Path: UPS.PowerSummary.APCStatusFlag, Type: Feature, ReportID: 0x06,
Offset: 16, Size: 8, Value: 8.000000
upsdrv_updateinfo...
Got -22 HID objects...
2005 Aug 26
0
NUT patches
...4.
----------------------------------------------------------------------
Before fixing the HIDParser bug:
HIDDumpTree...
Path: UPS.PowerSummary.iSerialNumber
Path: UPS.PowerSummary.iDeviceChemistry
Path: UPS.PowerSummary.iOEMInformation
Path: UPS.PowerSummary.Rechargeable
Path: UPS.PowerSummary.APCStatusFlag
Path: UPS.PowerSummary.APCStatusFlag
Path: UPS.PowerSummary.ManufacturerDate
Path: UPS.PowerSummary.ConfigVoltage
Path: UPS.PowerSummary.Voltage
Path: UPS.PowerSummary.iManufacturer
Path: UPS.PowerSummary.CapacityMode
Path: UPS.PowerSummary.RemainingCapacity
Path: UPS.PowerSummary.RemainingCapacity...
2005 Jul 22
1
Another HID USB UPS
...ew USB/HID UPS driver 0.23 (2.0.2)
Report Descriptor size = 872
Detected an UPS: APC/Back-UPS ES 650 FW:818.w1.D USB FW:w1
Path: UPS.PowerSummary.iSerialNumber
Path: UPS.PowerSummary.iDeviceChemistry
Path: UPS.PowerSummary.iOEMInformation
Path: UPS.PowerSummary.Rechargeable
Path: UPS.PowerSummary.APCStatusFlag
Path: UPS.PowerSummary.APCStatusFlag
Path: UPS.PowerSummary.ManufacturerDate
Path: UPS.PowerSummary.ConfigVoltage
Path: UPS.PowerSummary.Voltage
Path: UPS.PowerSummary.iManufacturer
Path: UPS.PowerSummary.CapacityMode
Path: UPS.PowerSummary.RemainingCapacity
Path: UPS.PowerSummary.RemainingCapacity...
2019 Jun 11
2
UPS shuts down on NUT boot with low battery [APS Back-UPS RS 550G]
...Offset: 0, Size: 8, Value: 1
> 0.028082 Path: UPS.PowerSummary.Discharging, Type: Input, ReportID: 0x06, Offset: 8, Size: 8, Value: 0
> 0.028965 Path: UPS.PowerSummary.Discharging, Type: Feature, ReportID: 0x06, Offset: 8, Size: 8, Value: 0
> 0.029785 Path: UPS.PowerSummary.APCStatusFlag, Type: Input, ReportID: 0x06, Offset: 16, Size: 8, Value: 8
> 0.030618 Path: UPS.PowerSummary.APCStatusFlag, Type: Feature, ReportID: 0x06, Offset: 16, Size: 8, Value: 8
> 0.031914 Path: UPS.PowerSummary.ManufacturerDate, Type: Feature, ReportID: 0x07, Offset: 0, Size: 16, Value: 18...
2018 Mar 06
0
APC UPS wrong input voltage
...1
> 4.348575 Report[get]: (3 bytes) => 14 00 00
> 4.348596 Path: UPS.PowerSummary.BelowRemainingCapacityLimit, Type: Feature, ReportID: 0x14, Offset: 0, Size: 8, Value: 0
> 4.348611 Report[buf]: (4 bytes) => 06 00 00 08
> 4.348622 Path: UPS.PowerSummary.APCStatusFlag, Type: Feature, ReportID: 0x06, Offset: 16, Size: 8, Value: 8
> 6.329754 upsdrv_updateinfo...
>
It's missing the report descriptor dump (part of the first few seconds) and the lines corresponding to voltages.
2019 Jun 11
0
UPS shuts down on NUT boot with low battery [APS Back-UPS RS 550G]
...0, Size: 8, Value: 1
>> 0.028082 Path: UPS.PowerSummary.Discharging, Type: Input, ReportID: 0x06, Offset: 8, Size: 8, Value: 0
>> 0.028965 Path: UPS.PowerSummary.Discharging, Type: Feature, ReportID: 0x06, Offset: 8, Size: 8, Value: 0
>> 0.029785 Path: UPS.PowerSummary.APCStatusFlag, Type: Input, ReportID: 0x06, Offset: 16, Size: 8, Value: 8
>> 0.030618 Path: UPS.PowerSummary.APCStatusFlag, Type: Feature, ReportID: 0x06, Offset: 16, Size: 8, Value: 8
>> 0.031914 Path: UPS.PowerSummary.ManufacturerDate, Type: Feature, ReportID: 0x07, Offset: 0, Size: 16, Val...
2018 Mar 03
2
APC UPS wrong input voltage
Folks,
I've asked this question on the FreeNAS forum but there are no ideas there
as it looks like it's a NUT issue.
Original question:
https://forums.freenas.org/index.php?threads/apc-ups-reporting-wrong-input-voltage.60888/
the nut driver is reporting the wrong input voltage. I am in the UK, 230V
but it's reporting circa 108.
If I connect it to the laptop and run powerchute it
2005 Jul 26
1
Some newhidups questions
...ly possible recovery seems to be to kill everything by some other means.
Yes, I know, Arnaud hinted at this, but I wanted to see where I am at,
and now I can see clearly where I need help!
Thanks, AG
------------------------------------------------------------------------------
UPS.PowerSummary.APCStatusFlag (2 bytes) => 06 08 == 8
UPS.Battery.APCBattReplaceDate (4 bytes) => 1C 00 00 00 == 0
UPS.Battery.APC860024 (5 bytes) => 28 06 96 0C 8C == ??
UPS.APC860018.Input (2 bytes) => 30 78 == 120
UPS.APC...
2005 Aug 13
1
A newhidups question
...un my UPS directly with newhidups -D -D -D, with no data changes,
and I then observe the interaction with my UPS (still Back-UPS ES 650
FW:818.w1.D USB FW:w1), I see the updateinfo cycle through 3 different forms:
(1) a (2 bytes) => 06 08 notification that provides one item:
UPS.PowerSummary.APCStatusFlag
Note that this element isn't defined in apc-hid.h, so nothing is
done here.
(2) a (4 bytes) => 0C 46 BE 05 notification that provides two items:
UPS.PowerSummary.RunTimeToEmpty and
UPS.PowerSummary.RemainingCapacity
Note that apc-hid.h specifies no translations for these va...
2012 Apr 09
2
libusb_get_report: Unknown error
...rmwareRevision, Type: Feature, ReportID: 0x34, Offset: 0, Size: 8, Value: 7
1.130457 Report[get]: (2 bytes) => 37 08
1.130465 Path: UPS.APC_USB_FirmwareRevision, Type: Feature, ReportID: 0x37, Offset: 0, Size: 8, Value: 8
1.136464 Report[get]: (2 bytes) => 38 48
1.136472 Path: UPS.APCStatusFlag, Type: Input, ReportID: 0x38, Offset: 0, Size: 8, Value: 72
1.136477 Report[buf]: (2 bytes) => 38 48
1.136482 Path: UPS.APCStatusFlag, Type: Feature, ReportID: 0x38, Offset: 0, Size: 8, Value: 72
1.142477 Report[get]: (2 bytes) => 32 00
1.142494 Path: UPS.APCPanelTest, Type: Featu...