2009 Mar 28
1
APCUPSD port 3551 permission problem
...WAKEUP 000 060 180 300 (default = 0)
#WAKEUP 60
# UPS Grace period after request to power off (seconds)
# SLEEP 020 180 300 600 (default = 20)
#SLEEP 180
# Low line voltage causing transfer to batteries
# The permitted values depend on your model as defined by last letter
# of FIRMWARE or APCMODEL. Some representative values are:
# D 106 103 100 097
# M 177 172 168 182
# A 092 090 088 086
# I 208 204 200 196 (default = 0 => not valid)
#LOTRANSFER 208
# High line voltage causing transfer to batteries
# The permitted values depend on your model as defined by last letter
#...
2005 Jul 09
1
apcsmart varibles
...ine voltage notch or spike
NUMXFERS : 0
TONBATT : 0 seconds
CUMONBATT: 0 seconds
XOFFBATT : N/A
SELFTEST : NO
STESTI : ON
STATFLAG : 0x008 Status Flag
DIPSW : 0x0F Dip Switch
REG3 : 0x00 Register 3
MANDATE : 08/23/93
SERIALNO : 00035452
BATTDATE : 08/23/93
NOMOUTV : 115
NOMBATTV : 24.0
APCMODEL : 7QD
END APC : Sat Jul 09 12:56:42 CDT 2005
But under NUT, all I get is this:
#./upsc APC-900@localhost
driver.name: apcsmart
driver.parameter.port: /dev/ttyb
driver.version: 2.0.2
driver.version.internal: 1.99.7
input.voltage: 114.7
ups.mfr: APC
ups.model: Smart-UPS
ups.serial: 00035452
ups.st...
2005 Jan 03
3
UPS - a little OT
Hi all.
Can someone recommend a good UPS for using with an * machine that
provides some linux tested software to do managed shutdown in case of
power loss?
Thanks.
Shoval Tomer,
IT Manager,
SofTov Advanced Systems, Ltd.
Office: +972-3-9230686 ext. 179
Fax: +972-3-9216642
Mobile: +972-54-8000200
2010 Aug 02
3
OT -- apcupsd messages
...nds
CUMONBATT: 0 seconds
XOFFBATT : N/A
SELFTEST : NO
STATFLAG : 0x07000008 Status Flag
MANDATE : 2007-07-06
SERIALNO : 8B0727R20810
BATTDATE : 2072-00-37
NOMINV : 120 Volts
NOMBATTV : 24.0 Volts
NOMPOWER : 780 Watts
FIRMWARE : 836.H5 .D USB FW:H5
APCMODEL : Back-UPS XS 1300 LC
END APC : Mon Aug 02 08:57:32 CDT 2010
Hmmmm... Noticing above that the third anniversary of this UPS' birth
(7/6/2007)
approacheth, I wonder if this might be APC's way of trying to scare me
into recycling...
2008 Dec 12
1
APC Backups-Pro 650 - Any way to use apcsmart?
...ATT: 0 seconds
XOFFBATT : N/A
SELFTEST : NO
STESTI : 336
STATFLAG : 0x07000048 Status Flag
REG1 : 0x00 Register 1
REG2 : 0x00 Register 2
REG3 : 0x00 Register 3
MANDATE : 05/23/99
SERIALNO : NB9921121779
BATTDATE : 10/14/08
NOMOUTV : 115 Volts
NOMBATTV : 12.0 Volts
FIRMWARE : 12.3.D
APCMODEL : CWD
END APC : Fri Dec 12 12:28:14 CST 2008
Any way to get this output with nut?
--