search for: apcgeneralcollect

Displaying 14 results from an estimated 14 matches for "apcgeneralcollect".

2007 Jan 26
1
newhidups output for Geek Squad GS1285U
...oltage Can't find object UPS.Battery.Temperature Can't find object UPS.Battery.ManufacturerDate Can't find object UPS.PowerSummary.APCBattReplaceDate Can't find object UPS.Battery.APCBattReplaceDate Can't find object UPS.PowerSummary.DelayBeforeShutdown Can't find object UPS.APCGeneralCollection.APCDelayBeforeShutdown Can't find object UPS.Battery.Test Can't find object UPS.ManufacturerDate Can't find object UPS.PowerSummary.ManufacturerDate Can't find object UPS.PowerSummary.PresentStatus.ShutdownImminent Can't find object UPS.PowerSummary.PresentStatus.Overload Can...
2019 Jun 11
2
UPS shuts down on NUT boot with low battery [APS Back-UPS RS 550G]
...eportID: 0x34, Offset: 0, Size: 16, Value: 128 > 0.075399 Path: UPS.Input.APCSensitivity, Type: Feature, ReportID: 0x35, Offset: 0, Size: 8, Value: 1 > 0.076023 Path: UPS.Input.APCLineFailCause, Type: Feature, ReportID: 0x36, Offset: 0, Size: 8, Value: 0 > 0.076649 Path: UPS.APCGeneralCollection.APCDelayBeforeReboot, Type: Feature, ReportID: 0x40, Offset: 0, Size: 8, Value: 0 > 0.077279 Path: UPS.APCGeneralCollection.APCDelayBeforeShutdown, Type: Feature, ReportID: 0x41, Offset: 0, Size: 16, Value: -1 > 0.077902 Path: UPS.APCGeneralCollection.DelayBeforeShutdown, Type: F...
2020 Sep 03
2
UPS reboots with APC UPS
...Type: Feature, ReportID: 0x34, Offset: 0, Size: 8, Value: 129 0.709363 Path: UPS.Input.APCSensitivity, Type: Feature, ReportID: 0x35, Offset: 0, Size: 8, Value: 1 0.713331 Path: UPS.Input.APCLineFailCause, Type: Feature, ReportID: 0x36, Offset: 0, Size: 8, Value: 0 0.717383 Path: UPS.APCGeneralCollection.APCDelayBeforeReboot, Type: Feature, ReportID: 0x40, Offset: 0, Size: 8, Value: 0 0.720381 Path: UPS.APCGeneralCollection.APCDelayBeforeShutdown, Type: Feature, ReportID: 0x41, Offset: 0, Size: 16, Value: -1 0.726432 Path: UPS.APCGeneralCollection.DelayBeforeShutdown, Type: Feature, R...
2018 Aug 24
2
APC Back-UPS CS 650 offdelay and startdelay
W dniu 24.08.2018 o 13:10, Charles Lepple pisze: > Sorry, I didn't mean to imply that the master branch was necessarily going to be different, just wanted to make sure you had everything set up to recompile. The real test is to see if things change after commenting out that line (such as by changing it to start with "//"): > > // { "shutdown.return", 0, 0,
2019 Jun 11
0
UPS shuts down on NUT boot with low battery [APS Back-UPS RS 550G]
...0x34, Offset: 0, Size: 16, Value: 128 >> 0.075399 Path: UPS.Input.APCSensitivity, Type: Feature, ReportID: 0x35, Offset: 0, Size: 8, Value: 1 >> 0.076023 Path: UPS.Input.APCLineFailCause, Type: Feature, ReportID: 0x36, Offset: 0, Size: 8, Value: 0 >> 0.076649 Path: UPS.APCGeneralCollection.APCDelayBeforeReboot, Type: Feature, ReportID: 0x40, Offset: 0, Size: 8, Value: 0 >> 0.077279 Path: UPS.APCGeneralCollection.APCDelayBeforeShutdown, Type: Feature, ReportID: 0x41, Offset: 0, Size: 16, Value: -1 >> 0.077902 Path: UPS.APCGeneralCollection.DelayBeforeShutdown, T...
2006 Sep 08
3
newhidups with APC Smart-UPS 1500
Hello, I'm using the stable amd64 port of Debian Linux. I installed (the latest) nut-2.0.1-4 and nut-usb packages for utilizing an APC Smart-UPS 1500 USB. I tried "apcupsd" first but "nut" makes an even more sophisticated impression on me and has more security options. I had problems with the newhidups driver. It didn't find a device with matching VendorID. And
2006 Nov 11
1
Help with newhidups subdriver for Dynex UPS
...oltage Can't find object UPS.Battery.Temperature Can't find object UPS.Battery.ManufacturerDate Can't find object UPS.PowerSummary.APCBattReplaceDate Can't find object UPS.Battery.APCBattReplaceDate Can't find object UPS.PowerSummary.DelayBeforeShutdown Can't find object UPS.APCGeneralCollection.APCDelayBeforeShutdown Can't find object UPS.Battery.Test Can't find object UPS.ManufacturerDate Can't find object UPS.PowerSummary.ManufacturerDate Can't find object UPS.PowerSummary.PresentStatus.ShutdownImminent Can't find object UPS.PowerSummary.PresentStatus.Overload Can...
2005 Aug 26
0
NUT patches
...gVoltage Path: UPS.Battery.Voltage Path: UPS.Battery.ff860024 Path: UPS.ff860018.Input Path: UPS.ff860018.ConfigVoltage Path: UPS.ff860018.Voltage Path: UPS.ff860018.LowVoltageTransfer Path: UPS.ff860018.HighVoltageTransfer Path: UPS.ff860018.ff860024 Path: UPS.ff860018.ff860061 Path: UPS.APC860052.APCGeneralCollection Path: UPS.APC860052.APCForceShutdown Path: UPS.APCDelayBeforeShutdown.PowerConverter Path: UPS.APCDelayBeforeShutdown.PercentLoad Path: UPS.ff860024.ff860001 Path: UPS.ff860024.ff860023 Path: UPS.ff860024.ff860026 Path: UPS.ff860025 Path: UPS.iProduct Path: UPS.APC_UPS_FirmwareRevision Path: UPS...
2006 Oct 18
2
newhidups with APC Smart-UPS 1500
...ery.Test Can't find object > > UPS.BatterySystem.Battery.Test Can't find object > > UPS.BatterySystem.Battery.Test Can't find object > > UPS.PowerSummary.APCPanelTest Can't find object > > UPS.PowerSummary.APCPanelTest Can't find object > > UPS.APCGeneralCollection.APCDelayBeforeShutdown > > Can't find object UPS.PowerSummary.DelayBeforeStartup > > Can't find object UPS.APCGeneralCollection.APCForceShutdown > > Can't find object UPS.APCGeneralCollection.APCDelayBeforeShutdown > > upsdrv_updateinfo... > > dstate_ini...
2010 Nov 07
3
Support of "shutdown.return" on a APC Back-UPS CS 500
Hi all, I am trying to get a APC Back-UPS CS 500 running on my QNAP 419P Nas. Since on all my work I figure out the following: from Network UPS Tools upscmd 2.4.1 [~] # upscmd -l qnapups Instant commands supported on UPS [qnapups]: beeper.disable - Disable the UPS beeper beeper.enable - Enable the UPS beeper beeper.mute - Temporarily mute the UPS beeper beeper.off - Obsolete (use
2006 Aug 02
1
nut-usb fink version
...00 9C F3 00 03 10 D2 > > entering string_to_path() > > Looking up UPS > > Looking up PowerSummary > > Looking up DelayBeforeShutdown > > Report : (8 bytes) =3D> 00 00 9C F3 00 03 10 D2 > > entering string_to_path() > > Looking up UPS > > Looking up APCGeneralCollection > > Looking up APCDelayBeforeShutdown > > Report : (8 bytes) =3D> 00 00 9C F3 00 03 10 D2 > > entering string_to_path() > > Looking up UPS > > Looking up Output > > Looking up DelayBeforeShutdown > > Report : (8 bytes) =3D> 00 00 9C F3 00 03 10 D2...
2005 Jul 26
1
Some newhidups questions
...(2 bytes) => 33 8B == 139 UPS.APC860018.HighVoltageTransfer (2 bytes) => 34 B1 == 177 UPS.APC860018.APC860024 (2 bytes) => 35 02 == 2 UPS.APC860018.APC860061 (2 bytes) => 36 00 == 0 UPS.APC860052.APCGeneralCollection (2 bytes) => 40 00 == 0 UPS.APC860052.APCForceShutdown (3 bytes) => 41 FF FF == ?? /* { "APCDelayBeforeShutdown", 0xff86007d }, Doesn't seem to make sense */ UPS.APC86007d.PowerConverter (2 bytes) => 50 04 == 4...
2005 Jul 22
1
Another HID USB UPS
...gVoltage Path: UPS.Battery.Voltage Path: UPS.Battery.ff860024 Path: UPS.ff860018.Input Path: UPS.ff860018.ConfigVoltage Path: UPS.ff860018.Voltage Path: UPS.ff860018.LowVoltageTransfer Path: UPS.ff860018.HighVoltageTransfer Path: UPS.ff860018.ff860024 Path: UPS.ff860018.ff860061 Path: UPS.APC860052.APCGeneralCollection Path: UPS.APC860052.APCForceShutdown Path: UPS.APCDelayBeforeShutdown.PowerConverter Path: UPS.APCDelayBeforeShutdown.PercentLoad Path: UPS.ff860024.ff860001 Path: UPS.ff860024.ff860023 Path: UPS.ff860024.ff860026 Path: UPS.ff860025 Path: UPS.iProduct Path: UPS.APC_UPS_FirmwareRevision Path: UPS...
2005 Aug 02
0
newhidups for APC Back-UPS ES 650
...gVoltage Path: UPS.Battery.Voltage Path: UPS.Battery.ff860024 Path: UPS.ff860018.Input Path: UPS.ff860018.ConfigVoltage Path: UPS.ff860018.Voltage Path: UPS.ff860018.LowVoltageTransfer Path: UPS.ff860018.HighVoltageTransfer Path: UPS.ff860018.ff860024 Path: UPS.ff860018.ff860061 Path: UPS.APC860052.APCGeneralCollection Path: UPS.APC860052.APCForceShutdown Path: UPS.APCDelayBeforeShutdown.PowerConverter Path: UPS.APCDelayBeforeShutdown.PercentLoad Path: UPS.ff860024.ff860001 Path: UPS.ff860024.ff860023 Path: UPS.ff860024.ff860026 Path: UPS.ff860025 Path: UPS.iProduct Path: UPS.APC_UPS_FirmwareRevision Path: UPS...