2006 Sep 08
3
newhidups with APC Smart-UPS 1500
Hello,
I'm using the stable amd64 port of Debian Linux. I installed (the
latest) nut-2.0.1-4 and nut-usb packages for utilizing an APC Smart-UPS
1500 USB. I tried "apcupsd" first but "nut" makes an even more
sophisticated impression on me and has more security options.
I had problems with the newhidups driver. It didn't find a device with
matching VendorID. And
2006 Oct 18
2
newhidups with APC Smart-UPS 1500
...253.000000
> > Path: UPS.Output.HighVoltageTransfer, Type: Feature, Value:
> > 253.000000
> > Path: UPS.Output.LowVoltageTransfer, Type: Input, Value: 208.000000
> > Path: UPS.Output.LowVoltageTransfer, Type: Feature, Value:
> > 208.000000
> > Path: UPS.Output.APCDelayBeforeStartup, Type: Input, Value: 0.000000
> > Path: UPS.Output.APCDelayBeforeStartup, Type: Feature, Value:
> > 0.000000
> > Path: UPS.Output.APCShutdownAfterDelay, Type: Input, Value:
> > 90.000000
> > Path: UPS.Output.APCShutdownAfterDelay, Type: Feature, Value:
> > 90.0...
2009 Sep 02
6
Selftest intervall, APC Smart-UPS 750 RM
Hello
I recently switched from apcupsd to NUT2.2.2 without
any troubles.
I tried to figure out how I can configure the self-test
intervall. The command upsrw lists only the variables
battery.charge.low
battery.runtime.low
ups.delay.shutdown
ups.delay.start
The command usbhid-ups -D and the listing under
http://obsvermes.org/cgi-bin/nut/upsstats.cgi?host=apcsmart at localhost&treemode
2009 Mar 13
7
Weird Load and Battery Temp Readings
I've acquired and installed NUT 2.4.1 on a D-Link DNS323 NAS. With
exception of Load and Battery Temp readings all works well. A upsc
ups at localhost command returns;
battery.charge: 100
battery.charge.low: 10
battery.charge.warning: 50
battery.date: 2001/09/25
battery.mfr.date: 2008/06/05
battery.runtime: 2122
battery.runtime.low: 120
battery.temperature: 3022999999999998800
battery.type:
2006 Feb 08
2
2.0.3-pre2: Spurious UPS UPS@localhost battery is
Peter Selinger wrote:
> Hm. I need more information, as NUT seems to garble the values even
> before I can see them. I am not so worried about the date and
> temperatures (although, strangely, the battery replacement date
> appears to be Sept 25, 2001, which makes no sense). But the voltage is
> definitely important.
>
> [...]
>
Thanks Peter - I'll send the new
2012 Apr 09
2
libusb_get_report: Unknown error
...: Feature, ReportID: 0x23, Offset: 0, Size: 16, Value: 255
1.064485 Report[get]: (3 bytes) => 24 c3 00
1.064510 Path: UPS.Output.LowVoltageTransfer, Type: Feature, ReportID: 0x24, Offset: 0, Size: 16, Value: 195
1.070500 Report[get]: (3 bytes) => 25 00 00
1.070523 Path: UPS.Output.APCDelayBeforeStartup, Type: Feature, ReportID: 0x25, Offset: 0, Size: 16, Value: 0
1.076500 Report[get]: (3 bytes) => 27 ff ff
1.076524 Path: UPS.Output.DelayBeforeShutdown, Type: Feature, ReportID: 0x27, Offset: 0, Size: 16, Value: -1
1.082458 Report[get]: (4 bytes) => 29 00 00 00
1.082466 Path: UPS....