2007 Sep 07
2
Bug#439055: hid driver tries to mmap huge area, fails
...) = 15 > write(2, "hid_lookup_usage: found 840004\n", 31) = 31 > write(2, "parsing Battery\n", 16) = 16 > write(2, "Looking up Battery\n", 19) = 19 > write(2, "hid_lookup_usage: found 840012\n", 31) = 31 > write(2, "parsing APCBattReplaceDate\n", 27) = 27 > write(2, "Looking up APCBattReplaceDate\n", 30) = 30 > write(2, "hid_lookup_usage: found ff860016"..., 33) = 33 > write(2, "Path depth = 3\n", 15) = 15 > write(2, "0: Usage(00840004)\n", 19) = 19 > write(2, "1...
2007 Jan 26
1
newhidups output for Geek Squad GS1285U
...lue: 0.000000 Path: UPS.Output., Type: Feature Path: UPS.Output.ConfigActivePower, Type: Feature, Value: 238.000000 Can't find object UPS.Battery.ConfigVoltage Can't find object UPS.Battery.Temperature Can't find object UPS.Battery.ManufacturerDate Can't find object UPS.PowerSummary.APCBattReplaceDate Can't find object UPS.Battery.APCBattReplaceDate Can't find object UPS.PowerSummary.DelayBeforeShutdown Can't find object UPS.APCGeneralCollection.APCDelayBeforeShutdown Can't find object UPS.Battery.Test Can't find object UPS.ManufacturerDate Can't find object UPS.PowerSumm...
2009 May 30
2
APC USB UPS vs FreeBSD 6.x
Hi, I have a customer who just bought an APC Back-UPS XS 1300 LCD and I thought I'd try the latest NUT with it (on an old-ish FreeBSD 6.x system). It sees the UPS but I can't actually query it for data, in the usbhid-ups debug output I see.. 30.840512 HIDGetEvents: failed to buffer report: Result too large 30.840600 Got -34 HID objects... 30.840681 Quick update...
2005 Jul 26
1
Some newhidups questions
...s, I know, Arnaud hinted at this, but I wanted to see where I am at, and now I can see clearly where I need help! Thanks, AG ------------------------------------------------------------------------------ UPS.PowerSummary.APCStatusFlag (2 bytes) => 06 08 == 8 UPS.Battery.APCBattReplaceDate (4 bytes) => 1C 00 00 00 == 0 UPS.Battery.APC860024 (5 bytes) => 28 06 96 0C 8C == ?? UPS.APC860018.Input (2 bytes) => 30 78 == 120 UPS.APC860018.ConfigVoltage (2 bytes) => 31 74 == 116 UPS.A...
2019 Jun 11
2
UPS shuts down on NUT boot with low battery [APS Back-UPS RS 550G]
...e: 1, Value: 0 > 0.064299 Path: UPS.PowerSummary.RemainingTimeLimit, Type: Feature, ReportID: 0x17, Offset: 0, Size: 16, Value: 120 > 0.065154 Path: UPS.PowerSummary.AudibleAlarmControl, Type: Feature, ReportID: 0x18, Offset: 0, Size: 8, Value: 1 > 0.065791 Path: UPS.Battery.APCBattReplaceDate, Type: Feature, ReportID: 0x1c, Offset: 0, Size: 24, Value: 599297 > 0.066410 Path: UPS.Battery.ManufacturerDate, Type: Feature, ReportID: 0x20, Offset: 0, Size: 16, Value: 19752 > 0.067027 Path: UPS.Battery.Test, Type: Input, ReportID: 0x21, Offset: 0, Size: 8, Value: 6 > 0.0...
2006 Nov 11
1
Help with newhidups subdriver for Dynex UPS
...lue: 0.000000 Path: UPS.Output., Type: Feature Path: UPS.Output.ConfigActivePower, Type: Feature, Value: 450.000000 Can't find object UPS.Battery.ConfigVoltage Can't find object UPS.Battery.Temperature Can't find object UPS.Battery.ManufacturerDate Can't find object UPS.PowerSummary.APCBattReplaceDate Can't find object UPS.Battery.APCBattReplaceDate Can't find object UPS.PowerSummary.DelayBeforeShutdown Can't find object UPS.APCGeneralCollection.APCDelayBeforeShutdown Can't find object UPS.Battery.Test Can't find object UPS.ManufacturerDate Can't find object UPS.PowerSumm...
2019 Jun 11
0
UPS shuts down on NUT boot with low battery [APS Back-UPS RS 550G]
...ue: 0 >> 0.064299 Path: UPS.PowerSummary.RemainingTimeLimit, Type: Feature, ReportID: 0x17, Offset: 0, Size: 16, Value: 120 >> 0.065154 Path: UPS.PowerSummary.AudibleAlarmControl, Type: Feature, ReportID: 0x18, Offset: 0, Size: 8, Value: 1 >> 0.065791 Path: UPS.Battery.APCBattReplaceDate, Type: Feature, ReportID: 0x1c, Offset: 0, Size: 24, Value: 599297 >> 0.066410 Path: UPS.Battery.ManufacturerDate, Type: Feature, ReportID: 0x20, Offset: 0, Size: 16, Value: 19752 >> 0.067027 Path: UPS.Battery.Test, Type: Input, ReportID: 0x21, Offset: 0, Size: 8, Value: 6 >&...
2005 Aug 26
0
NUT patches
...tus.00000000 Path: UPS.PowerSummary.PresentStatus.00000000 Path: UPS.PowerSummary.PresentStatus.00000000 Path: UPS.PowerSummary.PresentStatus.00000000 Path: UPS.PowerSummary.PresentStatus.00000000 Path: UPS.PowerSummary.RemainingTimeLimit Path: UPS.PowerSummary.AudibleAlarmControl Path: UPS.Battery.APCBattReplaceDate Path: UPS.Battery.ManufacturerDate Path: UPS.Battery.RemainingCapacity Path: UPS.Battery.RunTimeToEmpty Path: UPS.Battery.RunTimeToEmpty (NOTE: ### HERE) Path: UPS.Battery.RemainingTimeLimit Path: UPS.Battery.ConfigVoltage Path: UPS.Battery.Voltage Path: UPS.Battery.ff860024 Path: UPS...
2013 Aug 07
1
FreeNAS , NUT and APC BK500EI problem.
..., Type: Feature, ReportID: 0x05, Offset: 0, Size: 8, Value: 4 1.144027 Report[buf]: (3 bytes) => 15 2e 42 1.144042 Path: UPS.Battery.ManufacturerDate, Type: Feature, ReportID: 0x15, Offset: 0, Size: 16, Value: 16942 1.144076 Report[buf]: (4 bytes) => 45 13 14 01 1.144085 Path: UPS.Battery.APCBattReplaceDate, Type: Feature, ReportID: 0x45, Offset: 0, Size: 24, Value: 70675 1.144109 Report[buf]: (3 bytes) => 2c fa 00 1.144118 Path: UPS.Output.PercentLoad, Type: Feature, ReportID: 0x2c, Offset: 0, Size: 16, Value: 25 1.144205 Report[buf]: (3 bytes) => 12 ff ff 1.144214 Path: UPS.PowerSummary.De...
2005 Jul 22
1
Another HID USB UPS
...S.PowerSummary.PresentStatus.00000000 ....................... a total of 46 PresentStatus.00000000 lines Path: UPS.PowerSummary.PresentStatus.00000000 Path: UPS.PowerSummary.PresentStatus.00000000 Path: UPS.PowerSummary.RemainingTimeLimit Path: UPS.PowerSummary.AudibleAlarmControl Path: UPS.Battery.APCBattReplaceDate Path: UPS.Battery.ManufacturerDate Path: UPS.Battery.RemainingCapacity Path: UPS.Battery.RunTimeToEmpty Path: UPS.Battery.RunTimeToEmpty Path: UPS.Battery.RemainingTimeLimit Path: UPS.Battery.ConfigVoltage Path: UPS.Battery.Voltage Path: UPS.Battery.ff860024 Path: UPS.ff860018.Input Path: UPS.ff860...
2005 Aug 02
0
newhidups for APC Back-UPS ES 650
...ath: UPS.PowerSummary.PresentStatus.NeedReplacement Path: UPS.PowerSummary.PresentStatus.NeedReplacement Path: UPS.PowerSummary.PresentStatus.OverLoad Path: UPS.PowerSummary.PresentStatus.OverLoad Path: UPS.PowerSummary.RemainingTimeLimit Path: UPS.PowerSummary.AudibleAlarmControl Path: UPS.Battery.APCBattReplaceDate Path: UPS.Battery.ManufacturerDate Path: UPS.Battery.RemainingCapacity Path: UPS.Battery.RunTimeToEmpty Path: UPS.Battery.RunTimeToEmpty Path: UPS.Battery.RemainingTimeLimit Path: UPS.Battery.ConfigVoltage Path: UPS.Battery.Voltage Path: UPS.Battery.ff860024 Path: UPS.ff860018.Input Path: UPS.ff860...
2006 Aug 02
1
nut-usb fink version
...te > > Report : (8 bytes) =3D> 00 00 9C F3 00 03 10 D2 > > hu_find_infoval: searching for value =3D 0 > > > > hu_find_infoval: found not set (value: 0) > > > > entering string_to_path() > > Looking up UPS > > Looking up Battery > > Looking up APCBattReplaceDate > > Report : (8 bytes) =3D> 00 00 9C F3 00 03 10 D2 > > hu_find_infoval: searching for value =3D 0 > > > > hu_find_infoval: found not set (value: 0) > > > > entering string_to_path() > > Looking up UPS > > Looking up Output > > Looking up Per...
2009 Mar 13
7
Weird Load and Battery Temp Readings
...00000000000000000000000000000000000000000000000000000000.000000 Path: UPS.PowerSummary.iDeviceChemistry, Type: Feature, ReportID: 0x05, Offset: 0, Size: 8, Value: 4.000000 Path: UPS.Battery.ManufacturerDate, Type: Feature, ReportID: 0x15, Offset: 0, Size: 16, Value: 14533.000000 Path: UPS.Battery.APCBattReplaceDate, Type: Feature, ReportID: 0x45, Offset: 0, Size: 24, Value: 599297.000000 Path: UPS.Output.PercentLoad, Type: Feature, ReportID: 0x2c, Offset: 0, Size: 16, Value: 2000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000...
2020 Sep 03
2
UPS reboots with APC UPS
...Offset: 10, Size: 1, Value: 0 0.638381 Path: UPS.PowerSummary.RemainingTimeLimit, Type: Feature, ReportID: 0x17, Offset: 0, Size: 16, Value: 120 0.643414 Path: UPS.PowerSummary.AudibleAlarmControl, Type: Feature, ReportID: 0x18, Offset: 0, Size: 8, Value: 2 0.647381 Path: UPS.Battery.APCBattReplaceDate, Type: Feature, ReportID: 0x1c, Offset: 0, Size: 24, Value: 599297 0.651362 Path: UPS.Battery.ManufacturerDate, Type: Feature, ReportID: 0x20, Offset: 0, Size: 16, Value: 19579 0.654351 Path: UPS.Battery.Test, Type: Input, ReportID: 0x21, Offset: 0, Size: 8, Value: 6 0.654379 Path: U...
2006 Sep 08
3
newhidups with APC Smart-UPS 1500
Hello, I'm using the stable amd64 port of Debian Linux. I installed (the latest) nut-2.0.1-4 and nut-usb packages for utilizing an APC Smart-UPS 1500 USB. I tried "apcupsd" first but "nut" makes an even more sophisticated impression on me and has more security options. I had problems with the newhidups driver. It didn't find a device with matching VendorID. And
2006 Feb 08
2
2.0.3-pre2: Spurious UPS UPS@localhost battery is
Peter Selinger wrote: > Hm. I need more information, as NUT seems to garble the values even > before I can see them. I am not so worried about the date and > temperatures (although, strangely, the battery replacement date > appears to be Sept 25, 2001, which makes no sense). But the voltage is > definitely important. > > [...] > Thanks Peter - I'll send the new
2006 Oct 18
2
newhidups with APC Smart-UPS 1500
...e: Input > > Path: UPS.PresentStatus., Type: Input > > Path: UPS.PresentStatus., Type: Input > > Path: UPS.PresentStatus., Type: Feature > > Path: UPS.PresentStatus., Type: Feature > > Path: UPS.PresentStatus., Type: Feature Can't find object > > UPS.Battery.APCBattReplaceDate Can't find object > > UPS.Output.ConfigActivePower Can't find object > > UPS.PowerSummary.Charging Can't find object > > UPS.PowerSummary.Discharging Can't find object > > UPS.PowerSummary.ACPresent Can't find object > > UPS.PowerSummary.BelowR...
2015 Jan 09
0
persistent "low battery" condition
On Jan 8, 2015, at 11:43 PM, Graham Menhennitt <graham at menhennitt.com.au> wrote: > Hello Nutters, > > I'm running nut 2.7.2 on FreeBSD 10-stable (via the FreeBSD port) with an APC Back-UPS CS 350 connected via USB. I get persistent (every few minutes) messages logged "battery is low" but I don't understand why. I don't think it's for the reason
2015 Jan 12
2
persistent "low battery" condition
...fset: 0, Size: 16, Value: 302.3 771.680018 Path: UPS.PowerSummary.iDeviceChemistry, Type: Feature, ReportID: 0x05, Offset: 0, Size: 8, Value: 4 771.733652 Path: UPS.Battery.ManufacturerDate, Type: Feature, ReportID: 0x15, Offset: 0, Size: 16, Value: 12935 771.744709 Path: UPS.Battery.APCBattReplaceDate, Type: Feature, ReportID: 0x45, Offset: 0, Size: 24, Value: 263941 771.764677 Path: UPS.Output.PercentLoad, Type: Feature, ReportID: 0x2c, Offset: 0, Size: 16, Value: 73 771.784792 Path: UPS.PowerSummary.DelayBeforeShutdown, Type: Feature, ReportID: 0x12, Offset: 0, Size: 16, Value: -1 7...
2012 Apr 09
2
libusb_get_report: Unknown error
...S.Battery.Test, Type: Input, ReportID: 0x16, Offset: 0, Size: 8, Value: 6 0.950507 Report[buf]: (2 bytes) => 16 06 0.950550 Path: UPS.Battery.Test, Type: Feature, ReportID: 0x16, Offset: 0, Size: 8, Value: 6 0.956775 Report[get]: (4 bytes) => 45 06 06 05 0.956796 Path: UPS.Battery.APCBattReplaceDate, Type: Feature, ReportID: 0x45, Offset: 0, Size: 24, Value: 329222 0.962463 Report[get]: (3 bytes) => 15 a6 34 0.962473 Path: UPS.Battery.ManufacturerDate, Type: Feature, ReportID: 0x15, Offset: 0, Size: 16, Value: 13478 0.968487 Report[get]: (3 bytes) => 18 e8 03 0.968511 Path: U...