2005 Jan 16
6
pattern matching problem
How do I solve the problem with between patterns:
_1800
_1NXX
I would like all numbers 1800, 1877 etc to go through iaxtel
but all other numbers 1xxx via voipjet
Example in my extension.conf I have:
[iaxtel]
exten => _1700NXXXXXX,1,Dial(IAX2/xxxx:xxxxx@iaxtel.com/${EXTEN}@iaxtel)
exten => _1888NXXXXXX,1,Dial(IAX2/xxxx:xxxxx@iaxtel.com/${EXTEN}@iaxtel)
exten => _1877NXXXXXX,1,Dial(IAX2/xxxx:xxxxx@iaxtel.com/${EXTEN}@iaxtel)
exten => _1866NXXXXXX,1,Dial(IAX2/xxxx:xxxxx@iaxtel.com/${EXTEN}@iaxtel)
exten => _1800NXX...
2004 Jun 15
0
making * more like a normal pbx (ciscoata-186)
...exten => t,1,Hangup
; This is the default context for internal phones, both
; SIP and analog
[default]
include => internal-extn
; always route 7005554141 through Voicepulse
exten => 17005554141,1,Macro(dialout-VP,${EXTEN})
; IAXtel numbers (i.e. other 1700 numbers)
exten => _1700NXXXXXX,1,Dial(IAX2/${IAXINFO}@iaxtel.com/${EXTEN}@iaxtel)
; toll free numbers are routed first through VP then through IAXtel
exten => _1800NXXXXXX,1,Macro(dialout-VP-IAXtel,${EXTEN})
exten => _1855NXXXXXX,1,Macro(dialout-VP-IAXtel,${EXTEN})
exten => _1866NXXXXXX,1,Macro(dialout-VP-IAXtel,${EXT...
2003 Dec 02
5
IAXTEL configuration for new iaxtel users.
...=> s,2,Hangup ; You could add voicemail here.
[macro-iaxtel]
exten => s,1,Dial(IAX/${IAXTELUSERNAME}:${IAXTELPASSWORD}@iaxtel.com/${ARG1}@iaxtel)
exten => s,2,Playback(invalid)
exten => s,3,Hangup
[outbound]
exten => _1700NXXXXXX,1,macro(iaxtel,${EXTEN})
exten => _1800NXXXXXX,1,macro(iaxtel,${EXTEN})
exten => _1866NXXXXXX,1,macro(iaxtel,${EXTEN})
exten => _1877NXXXXXX,1,macro(iaxtel,${EXTEN})
exten => _1888NXXXXXX,1,macro(iaxtel,${EXTEN})
Before I get a chewing for the spacin...
2004 Dec 26
7
IAX Registration Refused
I tried to connect my * to IAXtel, but i always get this errors.
chan_iax2.c:5849 socket_read: Registration of 'mnetwork' rejected:
Registration Refused
On dial a iax number i get:
chan_iax2.c:5526 socket_read: Call rejected by 69.73.19.178: No authority
found
chan_iax2.c:5528 socket_read: Immediately destroying 3, having received
reject
chan_iax2.c:2411 iax2_hangup: We're hanging