Displaying 20 results from an estimated 21 matches for "800e".
Did you mean:
800
2006 Mar 09
0
fentonups: add Lestar MD-800E
...etworkupstools.org/
Debian Developer - http://people.debian.org/~aquette/
OpenSource Developer - http://arnaud.quette.free.fr/
Marek Majchrzak <nobbie __ link-net.pl> wrote:
> Hey!
>
> I wanted You to add Lestar UPS to te list of working ones on fentonups driver:
>
> Lestar MD-800E: works OK.
> ---------------
>
> Network UPS Tools - Fenton UPS driver 1.21 (2.0.0)
> Unknown ups - please report this ID string: #------------- ------ VT02052N
> Detected Unknown ----- on /dev/tty00
>
>
> Thanx for good software :-)
> Cya!
>
>
> --
> Po...
2008 Apr 01
1
Fwd: Cyberpower usbhid-ups wrong battery voltage
---------- Forwarded message ----------
From: davor emard <davoremard at gmail.com>
Date: Tue, 25 Mar 2008 09:09:40 +0100
Subject: Cyberpower usbhid-ups wrong battery voltage
To: libusb-devel at lists.sourceforge.net
HI
I have cyberpower value 800E connected via usb.
In the status battery voltage is too high 20V - 21V
while measurement at the battery terminals gives 13.6V
-------------- next part --------------
An embedded and charset-unspecified text was scrubbed...
Name: upsdump
Url: http://lists.alioth.debian.org/pipermail/nut-upsuser/atta...
2008 Jul 03
0
Cyberpower Value 600E UPS (unlisted) working
...t
> up using NUT 2.2.x (on Gentoo x86_64). Everything is working great,
> using the usbhid-ups driver, and the UPS isn't on the compatibility
> lists, so I figured I'd post a little heads-up that it works. The
> battery appears to be the main difference from the 400E and 800E
> models, so I expect them to work as well.
> I'm not sure that you're the right guy, I just took the address shown
> to last modify the stable compatibility list. Feel free to direct me
> to the mailing lists if necessary; I just didn't feel like signing up
> to...
2024 Jan 13
1
Cyber Power LE1000DG UPS
...ry-backup/le1000dg/.
TrueNAS has you pick a UPS driver. I could not find any "LE" related models on https://networkupstools.org/stable-hcl.html (which is the list TrueNAS uses). Per your guidance on that page, I tried one that I hoped was compatible: "Cyber Power Systems ups 2 Value 800E USB (usbhid-ups)". Every Cyber Power system with USB on the list there seems to use usbhid-ups anyway - so perhaps picking any of them is reasonable?
I can have the TrueNAS system power down when power is lost and the UPS runs on battery, but I see occasional messages about communications bei...
2018 Feb 01
1
testing shutdown: pc not restarting; and "ups unavailable" messages
> Have you checked the BIOS option "Power on when AC Returns"?
Yes, and I have set it to "always on" as opposed to "always off" or "last state".
> Does the UPS unit perform a delayed power off some time after the box shuts
> down?
I have no idea. How would I find out?
-------------- next part --------------
An HTML attachment was scrubbed...
2018 Feb 01
0
testing shutdown: pc not restarting; and "ups unavailable" messages
>
>> I see at http://networkupstools.org/ddl/Cyber_Power_Systems/Value_800E.html that
>> the Value 800E does not have variables such as
>> load.off.delay - Turn off the load with a delay (seconds)
>> load.on.delay - Turn on the load with a delay (seconds)
>>
>> What does command ? upscmd -l <UPS> ? report?
>
> I'll try this...
2015 Jan 15
2
dahdi_genconf fails with "Empty configuration - no spans"
...64 1:2.10.0.1~dfsg-1+3.16.7-ckt2-1 amd64 DAHDI modules for Linux (kernel 3.16.0-4-amd64)
ii dahdi-source 1:2.10.0.1~dfsg-1 all DAHDI telephony interface - source code for kernel driver
# dahdi_hardware
pci:0000:0a:00.0 wcte43x+ d161:800e Wildcard TE435/235
# lsmod|grep -E 'dahdi|wct'
wcte43x 56864 0
oct612x 162715 1 wcte43x
dahdi 212318 2 oct612x,wcte43x
crc_ccitt 12347 1 dahdi
However, dahdi_genconf keeps finding no span:
# dahdi_genconf -vvv
Default parame...
2008 Mar 18
3
distinguishing identical multiple usbhid-ups devices
HI
I would like to connect several Cyberpower Value 800E devices
over a USB hub to a single host. Problem is how to distinguish
them in order to correctly identify because lsusb -vvvv -d and upsc
show the same device name and serial number is 0
Bus 002 Device 012: ID 0764:0501 Cyber Power System, Inc.
idVendor 0x0764 Cyber Power System, Inc...
2018 Feb 27
2
df reports wrong full capacity for distributed volumes (Glusterfs 3.12.6-1)
...stor3data:/mnt/disk_b1/glusterfs/vol0/brick1
Brick4: stor3data:/mnt/disk_b2/glusterfs/vol0/brick1
Options Reconfigured:
performance.cache-size: 4GB
cluster.min-free-disk: 1%
performance.io-thread-count: 16
performance.readdir-ahead: on
Volume Name: volumedisk1
Type: Distribute
Volume ID: 591b7098-800e-4954-82a9-6b6d81c9e0a2
Status: Started
Snapshot Count: 0
Number of Bricks: 4
Transport-type: tcp
Bricks:
Brick1: stor1data:/mnt/glusterfs/vol1/brick1
Brick2: stor2data:/mnt/glusterfs/vol1/brick1
Brick3: stor3data:/mnt/disk_c/glusterfs/vol1/brick1
Brick4: stor3data:/mnt/disk_d/glusterfs/vol1/brick1...
2018 Feb 01
10
testing shutdown: pc not restarting; and "ups unavailable" messages
...H the PC was already off? I never imagined that... I guess it's something I could try independently, once I find a quiet time with no disk activity when it's OK to shut down that computer.
> I looked at the product documentation at
> https://www.cyberpower.com/uk/en/product/sku/Value800EILCD and could find
> nothing about shutting down the UPS power outlets. Although the 800EILCD is able
> to turn off the beeper, this in itself is not sufficient. The proposed typical
> applications include NAS & Servers so it should be possible. Perhaps you could
> ask the Cyber...
2018 Feb 28
0
df reports wrong full capacity for distributed volumes (Glusterfs 3.12.6-1)
...; Brick4: stor3data:/mnt/disk_b2/glusterfs/vol0/brick1
> Options Reconfigured:
> performance.cache-size: 4GB
> cluster.min-free-disk: 1%
> performance.io-thread-count: 16
> performance.readdir-ahead: on
>
> Volume Name: volumedisk1
> Type: Distribute
> Volume ID: 591b7098-800e-4954-82a9-6b6d81c9e0a2
> Status: Started
> Snapshot Count: 0
> Number of Bricks: 4
> Transport-type: tcp
> Bricks:
> Brick1: stor1data:/mnt/glusterfs/vol1/brick1
> Brick2: stor2data:/mnt/glusterfs/vol1/brick1
> Brick3: stor3data:/mnt/disk_c/glusterfs/vol1/brick1
> Brick4:...
2008 Mar 19
1
Re: conversion between Full-virtualization andPara-virtual
...ymap = "en-us"
disk = [ "phy:/dev/xenvg/rhel51x64f,hda,w","file:/root/RHEL5.1-Server-20071017.0-x86_64-DVD.iso,hdc:cdrom,r" ]
vif = [ "mac=00:16:3e:75:e8:4b,bridge=xenbr0" ]
serial = "pty"
I change to:
name = "test"
uuid = "1edde468-800e-3065-0336-cf4703c22cde"
maxmem = 1024
memory = 2048
vcpus = 2
bootloader = "/usr/bin/pygrub"
on_poweroff = "destroy"
on_reboot = "restart"
on_crash = "restart"
vfb = [ "type=vnc,vncunused=1,keymap=en-us" ]
disk = [ "phy:/dev/xenvg/rhel51x6...
2018 Feb 28
2
df reports wrong full capacity for distributed volumes (Glusterfs 3.12.6-1)
...sterfs/vol0/brick1
>> Options Reconfigured:
>> performance.cache-size: 4GB
>> cluster.min-free-disk: 1%
>> performance.io-thread-count: 16
>> performance.readdir-ahead: on
>>
>> Volume Name: volumedisk1
>> Type: Distribute
>> Volume ID: 591b7098-800e-4954-82a9-6b6d81c9e0a2
>> Status: Started
>> Snapshot Count: 0
>> Number of Bricks: 4
>> Transport-type: tcp
>> Bricks:
>> Brick1: stor1data:/mnt/glusterfs/vol1/brick1
>> Brick2: stor2data:/mnt/glusterfs/vol1/brick1
>> Brick3: stor3data:/mnt/disk_c/gl...
2002 Nov 14
0
WIN 3.1 App crashes.. Unhandled Exception
...NEL.60: FINDRESOURCE(02a6,00000002 #0002,0000000a #000a)
ret=051f:0565 ds=02a7
0820ac28:trace:resource:RES_FindResource2 (000002a6, 0000000a, 00000002, 0000,
A, NE)
0820ac28:trace:resource:NE_FindResource module=024f name=#0002 type=#000a
0820ac28:trace:resource:NE_FindTypeSection Skipping type 800e
0820ac28:trace:resource:NE_FindTypeSection Skipping type 8003
0820ac28:trace:resource:NE_FindTypeSection Found type 800a
0820ac28:trace:resource:NE_FindResource Found id 00000002
0820ac28:trace:global:GlobalHandle16 0137
0820ac28:Ret KERNEL.60: FINDRESOURCE() retval=026a ret=051f:0565 ds=0...
2009 Jul 28
4
Patch for drivers.list
...;USB" "usbhid-ups"
"Cyber Power Systems" "Value 400E" "USB" "usbhid-ups"
"Cyber Power Systems" "Value 600E" "USB" "usbhid-ups"
"Cyber Power Systems" "Value 800E" "USB" "usbhid-ups"
root(upsmonitor)/usr/local/etc/nut#
Regards,
Svein Skogen
- --
- --------+-------------------+-------------------------------
/"\ |Svein Skogen | svein at d80.iso100.no
\ / |Solberg ?stli 9 | PGP Key: 0xE5E76831
X...
2018 Feb 28
0
df reports wrong full capacity for distributed volumes (Glusterfs 3.12.6-1)
...ons Reconfigured:
>>> performance.cache-size: 4GB
>>> cluster.min-free-disk: 1%
>>> performance.io-thread-count: 16
>>> performance.readdir-ahead: on
>>>
>>> Volume Name: volumedisk1
>>> Type: Distribute
>>> Volume ID: 591b7098-800e-4954-82a9-6b6d81c9e0a2
>>> Status: Started
>>> Snapshot Count: 0
>>> Number of Bricks: 4
>>> Transport-type: tcp
>>> Bricks:
>>> Brick1: stor1data:/mnt/glusterfs/vol1/brick1
>>> Brick2: stor2data:/mnt/glusterfs/vol1/brick1
>>>...
2018 Feb 28
2
df reports wrong full capacity for distributed volumes (Glusterfs 3.12.6-1)
...t; performance.cache-size: 4GB
>>>> cluster.min-free-disk: 1%
>>>> performance.io-thread-count: 16
>>>> performance.readdir-ahead: on
>>>>
>>>> Volume Name: volumedisk1
>>>> Type: Distribute
>>>> Volume ID: 591b7098-800e-4954-82a9-6b6d81c9e0a2
>>>> Status: Started
>>>> Snapshot Count: 0
>>>> Number of Bricks: 4
>>>> Transport-type: tcp
>>>> Bricks:
>>>> Brick1: stor1data:/mnt/glusterfs/vol1/brick1
>>>> Brick2: stor2data:/mnt/gluster...
2018 Mar 01
0
df reports wrong full capacity for distributed volumes (Glusterfs 3.12.6-1)
...GB
>>>>> cluster.min-free-disk: 1%
>>>>> performance.io-thread-count: 16
>>>>> performance.readdir-ahead: on
>>>>>
>>>>> Volume Name: volumedisk1
>>>>> Type: Distribute
>>>>> Volume ID: 591b7098-800e-4954-82a9-6b6d81c9e0a2
>>>>> Status: Started
>>>>> Snapshot Count: 0
>>>>> Number of Bricks: 4
>>>>> Transport-type: tcp
>>>>> Bricks:
>>>>> Brick1: stor1data:/mnt/glusterfs/vol1/brick1
>>>>> Br...
2018 Mar 01
2
df reports wrong full capacity for distributed volumes (Glusterfs 3.12.6-1)
...cluster.min-free-disk: 1%
>>>>>> performance.io-thread-count: 16
>>>>>> performance.readdir-ahead: on
>>>>>>
>>>>>> Volume Name: volumedisk1
>>>>>> Type: Distribute
>>>>>> Volume ID: 591b7098-800e-4954-82a9-6b6d81c9e0a2
>>>>>> Status: Started
>>>>>> Snapshot Count: 0
>>>>>> Number of Bricks: 4
>>>>>> Transport-type: tcp
>>>>>> Bricks:
>>>>>> Brick1: stor1data:/mnt/glusterfs/vol1/brick1...
2018 Mar 01
0
df reports wrong full capacity for distributed volumes (Glusterfs 3.12.6-1)
...%
>>>>>>> performance.io-thread-count: 16
>>>>>>> performance.readdir-ahead: on
>>>>>>>
>>>>>>> Volume Name: volumedisk1
>>>>>>> Type: Distribute
>>>>>>> Volume ID: 591b7098-800e-4954-82a9-6b6d81c9e0a2
>>>>>>> Status: Started
>>>>>>> Snapshot Count: 0
>>>>>>> Number of Bricks: 4
>>>>>>> Transport-type: tcp
>>>>>>> Bricks:
>>>>>>> Brick1: stor1data:/m...