Displaying 20 results from an estimated 119 matches for "8,0".
Did you mean:
0,0
2010 Aug 06
0
Re: PATCH 3/6 - direct-io: do not merge logically non-contiguous requests
...2010 at 11:21:11AM -0400, Christoph Hellwig wrote:
>> On Wed, May 19, 2010 at 04:24:51PM -0400, Josef Bacik wrote:
>> > Btrfs cannot handle having logically non-contiguous requests submitted. For
>> > example if you have
>> >
>> > Logical: [0-4095][HOLE][8192-12287]
>> > Physical: [0-4095] [4096-8191]
>> >
>> > Normally the DIO code would put these into the same BIO''s. The problem is we
>> > need to know exactly what offset is associated with what BIO so we can do our
>> > checksumming and...
2004 Jul 14
1
Cluster Manager Issue on OCFS Firewire ?
I have set up an ocfs system using two linux nodes connected using
firewire.
Details:
# uname -a
Linux testrac2 2.4.21-9.0.1.ELorafw1 #1 Tue Mar 2 14:42:46 PST 2004 i686
i686 i386 GNU/Linux
# cat /etc/issue
Red Hat Enterprise Linux ES release 3 (Taroon Update 1)
# rpm -qa |grep ocfs
ocfs-tools-1.1.2-1
ocfs-2.4.21-EL-1.0.12-1
ocfs-support-1.1.2-1
<>
Oracle version: 9.2.0.5
Cluster manager version: 9.2.0.4.0.48
Everything appears to be fine the cluster m...
2011 May 17
3
Powercom issues in NUT (was: PowerCom BNT2000AT ups on nut 2.6.0 - second try)
...gt; [APC1]
> > >
> > > driver = powercom
> > > type = BNT
> > > port = /dev/ttyS1
> > > numOfBytesFromUPS = 16
> > > methodOfFlowControl = no_flow_control
> > > validationSequence = {{11,0x42},{8,0},{8,0}}
> > > shutdownArguments = {{1,30},y}
> > > modelname = BNT2000APT
> > > serialnumber = 2233445566
> > > desc = Computer Room Small UPS
> > >
> > > (...)
> >
> > a powercom patch has recently been...
2008 Mar 28
0
[08/17][PATCH] kvm/ia64: Add interruption vector table for vmm.
...;;
>+ tbit.z p6,p7=r29,IA64_PSR_VM_BIT
>+ tbit.z p0,p15=r29,IA64_PSR_I_BIT
>+ ;;
>+(p7) br.sptk kvm_dispatch_interrupt
>+ ;;
>+ mov r27=ar.rsc /* M */
>+ mov r20=r1 /* A */
>+ mov r25=ar.unat /* M */
>+ mov r26=ar.pfs /* I */
>+ mov r28=cr.iip /* M */
>+ cover /* B (or nothing) */
>+ ;;
>+ mov r1=sp
>+ ;;
>+ invala /* M */
>+ mov r30=cr.ifs
>+ ;;
>+ addl r1=-VMM_PT_REGS_SIZE,r1
>+ ;;
>+ adds r17=2*L1_CACHE_BYTES,r1 /* really: biggest cache-line
>size */
>+ a...
2008 Mar 28
0
[08/17][PATCH] kvm/ia64: Add interruption vector table for vmm.
...;;
>+ tbit.z p6,p7=r29,IA64_PSR_VM_BIT
>+ tbit.z p0,p15=r29,IA64_PSR_I_BIT
>+ ;;
>+(p7) br.sptk kvm_dispatch_interrupt
>+ ;;
>+ mov r27=ar.rsc /* M */
>+ mov r20=r1 /* A */
>+ mov r25=ar.unat /* M */
>+ mov r26=ar.pfs /* I */
>+ mov r28=cr.iip /* M */
>+ cover /* B (or nothing) */
>+ ;;
>+ mov r1=sp
>+ ;;
>+ invala /* M */
>+ mov r30=cr.ifs
>+ ;;
>+ addl r1=-VMM_PT_REGS_SIZE,r1
>+ ;;
>+ adds r17=2*L1_CACHE_BYTES,r1 /* really: biggest cache-line
>size */
>+ a...
2007 Dec 29
1
Odd Values For Powercoms
...m the
manpage.
All the values look "sane" when I'm on-line, but note some of the odd
values (<-- Here) when on battery:
Also, does anyone know if this UPS supports logging of the "boost" or
"buck" lights?
BATTERY:
ads-bsh-fwd4# upsc ups1
battery.charge: 158.9 <-- Wierd
driver.name: powercom
driver.parameter.batteryPercentage: {5.0000,0.3268,-825.00,0.46511,0}
driver.parameter.frequency: {0.00020997,0.0}
driver.parameter.linevoltage: 110
driver.parameter.loadPercentage: {6.1343,-0.3808,1.075,0.1811}
driver.parameter.manufacturer: PowerCom
driver.par...
2005 Dec 30
2
BNT600AP
...model name : 'Unknown'
serial number : 'Unknown'
line voltage : '230'
type : 'Trust'
number of bytes from UPS: '11'
method of flow control : 'dtr0rts1'
validation sequence: '{{5,0},{7,0},{8,0}}'
shutdown arguments: '{{0,10},n}'
frequency calculation coefficients: '{0.000210,0.000209}'
load percentage calculation coefficients:
'{6.134300,-0.380800,4.311000,0.181100}' battery percentage calculation
coefficients: '{5.000000,0.326800,-825.000000,4.563900...
2006 Aug 18
0
(no subject)
...#39;
model name : 'Unknown'
serial number : 'Unknown'
line voltage : '220'
type : 'KP625AP'
number of bytes from UPS: '16'
method of flow control : 'dtr0rts1'
validation sequence: '{{5,0x80},{7,0},{8,0}}'
shutdown arguments: '{{1,0},y}'
frequency calculation coefficients: '{0.000210,0.000209}'
load percentage calculation coefficients: '{6.134300,-0.380800,4.311000,0.181100}'
battery percentage calculation coefficients: '{5.000000,0.326800,-825.0000...
2003 Jan 30
2
Auth PPTP X SAMBA
Good Morning,
My doubt and the following one: I have a server with SuSE 8,0 using
VPN PPTP, would like to know as I can make with that the users if
Authentication for the samba.
Regards
Fabio Sena
Brasil - PE
2005 Aug 03
0
Compile ZAPTEL warning and Strange Congestion
.../asm/system.h:190: warning:
dereferencing type-punned pointer will break strict-aliasing rules
Just a warning - didn't bother me too much as everything worked any way.
But it did come up in most of the source files. I think it's just a
compiler option missing. 2.4.26 isn't exactly new 8-)
I only use my * box for a home PBX - nothing critical about it.
Then I started noticing this in the CLI:
Jul 29 13:25:54 WARNING[9075]: chan_zap.c:3696 zt_handle_event:
Ring/Off-hook in strange state 7 on channel 4
Jul 29 13:26:06 NOTICE[9078]: chan_zap.c:5797 ss_thread: Got event 2
(Ring/Answe...
2011 May 13
1
PowerCom BNT2000AT ups on nut 2.6.0 - second try
...T2000AT
"Driver" is powercom
ups.conf looks like this! Okay so APC1 is not and APC!
[APC1]
driver = powercom
type = BNT
port = /dev/ttyS1
numOfBytesFromUPS = 16
methodOfFlowControl = no_flow_control
validationSequence = {{11,0x42},{8,0},{8,0}}
shutdownArguments = {{1,30},y}
modelname = BNT2000APT
serialnumber = 2233445566
desc = Computer Room Small UPS
I running /lib/nut/powercom -a APC1 -DDDDDDDDDD (Okay so the debugs are
overboard!!!)
Result is this!
Network UPS Tools - PowerCom protocol UP...
2010 Feb 04
0
Powercom BNT-800AP
...above, the Powercom upsmon software appears to special-case
those ~5/15V results, and on the next update, report it as 0V. I have
no idea how to even special-case the screwy input/output-swapping
behavior...
./powercom -a ups0 -DDD
Network UPS Tools - PowerCom protocol UPS driver 0.12 (2.4.1-2308)
0.000000 debug level is '3'
0.001406 Flow control disable
0.150003 Detected: BNT-other-500AP , 120V
0.153986 Values of arguments:
0.154001 manufacturer : 'PowerCom'
0.154009 model name : 'BNT-other-500AP'...
2008 Feb 25
6
[PATCH 0/4] ia64/xen: paravirtualization of hand written assembly code
Hi. The patch I send before was too large so that it was dropped from
the maling list. I'm sending again with smaller size.
This patch set is the xen paravirtualization of hand written assenbly
code. And I expect that much clean up is necessary before merge.
We really need the feed back before starting actual clean up as Eddie
already said before.
Eddie discussed how to clean up and suggested
2005 Aug 19
1
Sustainer S-1000C (Powercom protocol)
...>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>| Battery Status: Normal
|
| Avr Status: Bypass
|
AC Input Voltage 197.0V | UPS Status: Normal
>>>>>>>>>>>>>>|
| Temp: 37.8°C
|
| Line Freq.: 49.9Hz
AC Output Voltage 232.0V |
>>>>>>>>>>>>>>>>>>>>>>>| Serial Port: /dev/ttyS0
|
| Comm. Status: Conn.
|
|
Press Ctrl_C to Exit UPSMON Plus Display Program!!
Nevertheless, I haven't managed to make NUT...
2008 Feb 25
6
[PATCH 0/4] ia64/xen: paravirtualization of hand written assembly code
Hi. The patch I send before was too large so that it was dropped from
the maling list. I'm sending again with smaller size.
This patch set is the xen paravirtualization of hand written assenbly
code. And I expect that much clean up is necessary before merge.
We really need the feed back before starting actual clean up as Eddie
already said before.
Eddie discussed how to clean up and suggested
2013 May 01
1
Powercom BNT-1500AP serial config
...battery.charge: -197.6
device.mfr: PowerCom
device.model: KIN-1500AP
device.serial: Unknown
device.type: ups
driver.name: powercom
driver.parameter.pollinterval: 2
driver.parameter.port: /dev/ttyS0
driver.parameter.type: BNT-other
driver.version: 2.4.3
driver.version.internal: 0.12
input.frequency: 80.12
input.voltage: 99.8
input.voltage.nominal: 120
output.frequency: 80.12
output.voltage: 99.8
ups.load: 9.0
ups.mfr: PowerCom
ups.model: KIN-1500AP
ups.model.type: KIN
ups.serial: Unknown
ups.status: OL
/lib/nut/powercom -a ups -DDDDDDD: Output attached.
Later,
--
Bill Carlson
Anything is...
2006 May 30
3
Faster way to zero-pad a data frame...?
...eginning of the network log, and the number of network events that fell on that timestamp.
Example:
time,events
0,1
1,30
5,14
10,4
*data2 is the zero-padded data frame. It has length equal to the greatest value of "time" in data2:
time,events
1,0
2,0
3,0
4,0
5,0
6,0
7,0
8,0
9,0
10,0
So I run this for loop:
for(i in 1:length(data1[,1])) {
data2[data1[i,1],2]<-data1[i,2]
}
Which goes to each row in data1, reads the timestamp, and writes the "events" to the corresponding row in data2. The result is:
time,events
0,1
1,30
2,0
3,0
4,0
5...
2010 Feb 16
2
wrong number of arguments (Wrox Beginning Ruby On Rails)
...------+--------------+------+-----+---------+----------------+
| Field | Type | Null | Key | Default | Extra |
+-------------+--------------+------+-----+---------+----------------+
| id | int(11) | NO | PRI | NULL | auto_increment |
| name | varchar(80) | NO | | NULL | |
| description | text | NO | | NULL | |
| price | decimal(8,0) | NO | | NULL | |
+-------------+--------------+------+-----+---------+----------------+
4 rows in set (0.07 sec)
I typed to mak...
2011 Aug 09
7
Disk IDs and DD
Hiya,
Is there any reason (and anything to worry about) if disk target IDs don''t start at 0 (zero). For some reason mine are like this (3 controllers - 1 onboard and 2 PCIe);
AVAILABLE DISK SELECTIONS:
0. c8t0d0 <ATA -ST9160314AS -SDM1 cyl 19454 alt 2 hd 255 sec 63>
/pci at 0,0/pci10de,cb84 at 5/disk at 0,0
1. c8t1d0 <ATA -ST9160314AS -SDM1 cyl 19454 alt 2 hd 255 sec 63>
/pci at 0,0/pci10de,cb84 at 5/disk at 1,0
2. c9t7d0 <ATA-HitachiHDS72302...
2007 Jun 03
0
Strange problem with channel allocation
...14
== Console is full duplex
-- Executing [1014@default:1] Dial("OSS/dsp", "SIP/1014|40|t") in new
stack
[2007-06-03 20:16:10] DEBUG[27424]: res_config_mysql.c:650 mysql_reconnect:
MySQL RealTime: Everything is fine.
[2007-06-03 20:16:10] DEBUG[27424]: res_config_mysql.c:138 realtime_mysql:
MySQL RealTime: Retrieve SQL: SELECT * FROM sip_peers WHERE name = '1014'
-- Called 1014
[2007-06-03 20:16:10] WARNING[27424]: channel.c:3222
ast_channel_make_compatible: No path to translate from
SIP/1014-081e93c0(256) to OSS/dsp(64)
[2007-06-03 20:16:10] WARNING[27424]...