2013 Feb 11
5
OT: UPS battery vendor
Hi, folks. I need some new replacement batteries for rack-mount APC UPSes. My old vender... well, the salesman I dealt with for several years left about a year and a half ago, and last year's purchase was a disaster (wrong batteries, wrong batteries, months to get the shipping to return the wrong batteries...), so I'm looking for a new, reliable vendor who does US government contract
2019 Sep 11
2
Debian 10 nut 2.7.4-8 and APC Back UPS 600i on 940-0020B
..." from another terminal I restart: # systemctl restart nut-driver.service after some seconds the status is changed to simply "OL". Also for sure I was unplug 230V from UPS the system was shutdown after about 15 min and at finish the UPS was switched off, as usually (I was used a 12V/7Ah accumulator to get result faster). Unfortunately I do not know ho to automatize this "work around". Any suggestion? tovis _______________________________________________ > Nut-upsuser mailing list > Nut-upsuser at alioth-lists.debian.net > https://alioth-lists.debian.net/cgi...
2008 Oct 26
3
2 (very old) bugs?
Hi everybody, Is someone can confirm me that there are 2 bugs never fixed: - first in the stat command. Only with the -x option. If you execute stat -x on /tmp or /usr/bin/passwd parameters for example, the numeric representation of mode is wrong. The "special" bits are always 0. No suid-bit, no sticky bit! - Second. Because of a missing suid-bit on the newgrp command, this
2008 Oct 27
1
Megatec and Batteries
...battery. This packed battery has two very important electrical characteristics for your UPS: nominal voltage (V) and capacity (Ah). Usually you will meet 6V (3 cell) and 12 V (6 cell) batteries in UPS. This represents nominal voltage of battery. In 70% of ups devices usually is used battery of 12V/7Ah in some rare cases 12V/9Ah or 6V/4.5Ah. Depending on ups power rating in output different number of batteries is used and common values are: UPS Technology UPS rated power number of batteries total battery voltage Interactive...
2023 Feb 06
2
Question about Tripp-Lite UPS life span
Hello, Somewhat off-topic, but seeking some input from other tech folk on this list. I have a Tripp-Lite SMART 2200 (a white tower that looks similar to, but predates the black SMART2200NET) that just failed its monthly battery test so I bought new batteries and replaced the old ones. Sadly once put back together, plugged in and enabled it did not power up--no lights, sounds, smoke, etc. I took
2024 Nov 13
4
Eaton 5PX 3rd party batteries
On 11/12/2024 10:58 AM, Dan Langille via Nut-upsuser wrote: > Hello, > > nut recently told me that the batteries need replacing in my Eaton 5PX2200RT (ups) and 5PXEBM48RT (external battery pack). According to my notes, it has been just over 4 years since I installed them. Looking at on-line sales, these seem to use batteries in a pre-packaged plastic shell. I don't recall if
2007 Aug 08
1
Mustek PowerMust 1000AV USB feedbacks
...in battery mode (and that is not the noise of the beeper for sure, it is more like a big voltage transformer - we don't really need the beeper ;). It is shipped with a java WinPower monitoring tool for linux. I did not try it yet (i'm not really fan with bundled tools). The ups has two 12V 7ah battery packs. It is a line-interactive. The fan is regulated (+40db) and does not stop even if the ups is powered off. To stop it, unplug the wall socket ;) I proceed 3 tests, - with the serial interface and the megatec driver - with the usb interface and the megatec_usb driver - a forced shutdow...
2007 Aug 08
1
Mustek PowerMust 1000AV USB feedbacks
...in battery mode (and that is not the noise of the beeper for sure, it is more like a big voltage transformer - we don't really need the beeper ;). It is shipped with a java WinPower monitoring tool for linux. I did not try it yet (i'm not really fan with bundled tools). The ups has two 12V 7ah battery packs. It is a line-interactive. The fan is regulated (+40db) and does not stop even if the ups is powered off. To stop it, unplug the wall socket ;) I proceed 3 tests, - with the serial interface and the megatec driver - with the usb interface and the megatec_usb driver - a forced shutdow...
2008 Jun 30
4
Rebuild of kernel 2.6.9-67.0.20.EL failure
Hello list. I'm trying to rebuild the 2.6.9.67.0.20.EL kernel, but it fails even without modifications. How did I try it? Created a (non-root) build environment (not a mock ) Installed the kernel.scr.rpm and did a rpmbuild -ba --target=`uname -m` kernel-2.6.spec 2> prep-err.log | tee prep-out.log The build failed at the end: Processing files: kernel-xenU-devel-2.6.9-67.0.20.EL Checking