Help with Elite 800VA usb UPS
...10.4 and 13.0) in order to run the calibration, and then adjust them
>> to the actual reported values.
>>
>>
>>
>
-------------- next part --------------
An HTML attachment was scrubbed...
URL: <http://lists.alioth.debian.org/pipermail/nut-upsuser/attachments/20170626/77636a3f/attachment-0001.html>
2017 Jun 16
3
Help with Elite 800VA usb UPS
Thanks mates,
as suggested I have added
runtimecal = 240,100,720,50
default.battery.voltage.low = 10.4
default.battery.voltage.high = 13.8 (the actual charging voltage)
In ups.conf
I have also added the startup procedure in rc.local file, everything is
fine...
I have only to make a deep test.
Is there a way to add a NOTIFYMSG value for the battery test?
Thank you lots