Displaying 6 results from an estimated 6 matches for "73f8".
Did you mean:
738
2019 Mar 13
1
SPN and case sensitivity on LMDB backend
Hi everyone,
samba-tool dbcheck --reindex
Re-indexing...
../ldb_tdb/ldb_index.c:2352: duplicate attribute value in
CN=WSTEST,OU=vm,OU=computers,OU=test,DC=ad,DC=test,DC=it for index on
servicePrincipalName, duplicate of objectGUID
4c723426-73f8-4991-bf95-88eb57840c2c in
@INDEX:SERVICEPRINCIPALNAME:TERMSRV/WSTEST.AD.TEST.IT
Looking at the computer entry, I indeed have thoses two SPN (notice the
case of hostname).
servicePrincipalName: TERMSRV/WSTEST.ad.test.it
servicePrincipalName: TERMSRV/wstest.ad.test.it
Looking at documentation fr...
2017 Jul 07
3
Re: virt-v2v import from KVM without storage-pool ?
...virt-v2v: This guest has virtio drivers installed.
[ 52.2] Mapping filesystem data to avoid copying unused and blank areas
[ 52.4] Closing the overlay
[ 52.7] Checking if the guest needs BIOS or UEFI to boot
[ 52.7] Assigning disks to buses
[ 52.7] Copying disk 1/1 to /tmp/v2v.Zzc4KD/c9cfeba7-73f8-428a-aa77-9a2a1acf0063/images/c8eb039e-3007-4e08-9580-c49da8b73d55/f76d16ea-5e66-4987-a496-8f378b127986 (qcow2)
(100.00/100%)
[ 152.4] Creating output metadata
[ 152.6] Finishing off
Result:
So this problem is caused by vdsm or ovirt
Regards
Ming Xie
----- Original Message -----
From: "...
2017 Jul 07
1
Re: virt-v2v import from KVM without storage-pool ?
...alled.
>> [ 52.2] Mapping filesystem data to avoid copying unused and blank areas
>> [ 52.4] Closing the overlay
>> [ 52.7] Checking if the guest needs BIOS or UEFI to boot
>> [ 52.7] Assigning disks to buses
>> [ 52.7] Copying disk 1/1 to /tmp/v2v.Zzc4KD/c9cfeba7-73f8-428a-aa77-9a2a1acf0063/images/c8eb039e-3007-4e08-9580-c49da8b73d55/f76d16ea-5e66-4987-a496-8f378b127986 (qcow2)
>> (100.00/100%)
>> [ 152.4] Creating output metadata
>> [ 152.6] Finishing off
>>
>>
>> Result:
>> So this problem is caused by vdsm or ovi...
2017 Jul 05
3
virt-v2v import from KVM without storage-pool ?
hi,
i'm trying to import a VM in oVirt from a KVM host that doesn't use
storage pools. this fails with the following message in
/var/log/vdsm/vdsm.log:
2017-07-05 09:34:20,513+0200 ERROR (jsonrpc/5) [root] Error getting disk
size (v2v:1089)
Traceback (most recent call last):
File "/usr/lib/python2.7/site-packages/vdsm/v2v.py", line 1078, in
_get_disk_info
vol =
2017 Jul 07
0
Re: virt-v2v import from KVM without storage-pool ?
...virtio drivers installed.
> [ 52.2] Mapping filesystem data to avoid copying unused and blank areas
> [ 52.4] Closing the overlay
> [ 52.7] Checking if the guest needs BIOS or UEFI to boot
> [ 52.7] Assigning disks to buses
> [ 52.7] Copying disk 1/1 to /tmp/v2v.Zzc4KD/c9cfeba7-73f8-428a-aa77-9a2a1acf0063/images/c8eb039e-3007-4e08-9580-c49da8b73d55/f76d16ea-5e66-4987-a496-8f378b127986 (qcow2)
> (100.00/100%)
> [ 152.4] Creating output metadata
> [ 152.6] Finishing off
>
>
> Result:
> So this problem is caused by vdsm or ovirt
>
> Regards
>...
2019 Apr 24
0
Replication failures
...a) [0x7f35a44aa68c]
> #42
> /usr/lib/x86_64-linux-gnu/samba/libldb.so.1(ldb_module_done+0x
1fc) [0x7f35b3dc7b6c]
> #43
> /usr/lib/x86_64-linux-gnu/samba/ldb/partition.so(+0x3b07)
> [0x7f359c9b8b07]
> #44
> /usr/lib/x86_64-linux-gnu/samba/libldb-key-value-samba4.so(+0x
73f8) [0x7f359e61f3f8]
> #45
> /usr/lib/x86_64-linux-gnu/samba/libldb-key-value-samba4.so(+0x
7c4b) [0x7f359e61fc4b]
> #46
> /usr/lib/x86_64-linux-gnu/samba/libtevent.so.0(tevent_common_i
nvoke_timer_handler+0x2ae) [0x7f35b377f3a6]
> #47
> /usr/lib/x86_64-linux-gnu/samba/libte...