2005 Oct 05
2
Sipura SPA-3000 setup in Brazil
...finding the relevant
information on how to make the thing pick up the PSTN line and make an
outbound call.
The sipura in question works fine on a bench connected to a POTS line in the
US, but is now plugged in in Sao Paolo. The immediate thing I notice is that
the voltage is high by US standards- 66v, as opposed to 48. But no
combination of settings will seem to make it work properly- attempted
outbound calls generate dead air. A brazilian POTS phone hooked up to the
FXS port on the unit works just fine- I can ring it, and it can call into
Asterisk.