Displaying 2 results from an estimated 2 matches for "52462bde".
2020 Jun 22
0
Low Battery Problems
...n for that NUT user.
Ref: https://networkupstools.org/docs/man/upsd.users.html <https://networkupstools.org/docs/man/upsd.users.html>
-------------- next part --------------
An HTML attachment was scrubbed...
URL: <http://alioth-lists.debian.net/pipermail/nut-upsuser/attachments/20200622/52462bde/attachment.html>
2020 Jun 22
2
Low Battery Problems
On Monday 22 June 2020 08:19:15 Charles Lepple wrote:
> > On Jun 18, 2020, at 12:39 PM, Mike Dillinger wrote:
> >
> > ups.test.result: No test initiated
>
> I’d recommend a battery test. Starting the test via the front panel
> should be sufficient, or you might be able to do it with upscmd.
from man pi at rpi4:~ $ upscmd -l myups
Instant commands supported on UPS