Displaying 20 results from an estimated 34 matches for "500va".
Did you mean:
1500va
2007 Apr 25
1
Re: Sweex UPS 500VA and NUT problem
Arjan,
I am forwarding your email to the nut-upsuser mailing list. I am not
an expert on the Powermust driver; hopefully somebody on the mailing
list will be able to help you!
-- Peter
Arjan DJ wrote:
>
> Dear Peter,
> Some days ago I bought a Sweex UPS (500VA) and now I have set up NUT (using
> the Powermust driver) and everything is working fine. Invoking upsmon -c fsd
> gives me a beautifull gracefull shutdown and upsc gives me reliable output.
> I have only one problem: when I'm really using the UPS (upsc shows "OB") my
> PC...
2005 Oct 03
2
driver for Elite 2005 500VA
Hello,
I've just finish a new driver for the Nitram UPS Elite 2005 500VA
(compiled and tested with nut-2.0.1 and nut-2.1.0).
Currently, all Nitram UPS are made by CyberPower, but the protocol is
different
than cyberpower.c. I don't have other model to test with, but I think
this driver could monitor
all Nitram 2005 UPS.
I don't have the protocol specificati...
2005 Oct 16
0
Sweex UPS 500VA
Hi,
FYI for all whom have the Sweex manageable UPS.
I got my sweex manageable UPS500VA working with NetworkUPSTools using the
ippon driver. Here is my the ups.conf file:
[ups]
driver = ippon
port = /dev/cuad0
desc = "Server"
Has anyone tried the ippon driver with Sweex 600VA, 700VA, and 800VA models?
Regards,
Jan
2013 Oct 26
1
[HCL] Syndome Era Series 500VA 400W supported by blazer_usb
Syndome Era Series
*upsc output*
*
*battery.charge: 100
battery.runtime: 1000 <-- not reported by UPS (guesstimate)
battery.voltage: 13.60
battery.voltage.high: 13.00
battery.voltage.low: 10.40
battery.voltage.nominal: 12.0
device.type: ups
driver.flag.novendor: enabled
driver.name: blazer_usb
driver.parameter.chargetime: 43200
driver.parameter.idleload: 30
driver.parameter.pollinterval: 5
2011 Jan 23
1
Getting a Plexus 500VA to work with NUT
Hi all,
First off thanks you for such a great tool - my searching so far
indicates that the developers and community behind nut are committed
and doing a great job!
Background: I've just purchased a Plexus 500VA UPS for ebuyer because
it was cheap. I didnt expect much but I've seen a few references to
people getting the same and similar models to work with NUT so was
encouraged to try! The NUT website compatability chart lists that the
blazer_usb driver is the correct one to use.
The monitoring server...
2018 Jul 01
2
No run cmd /usbhid-ups -k !
Good day.
Can not perform shutdowns Ups. Please help.
Details of our installation are:
OS: Turris Omnia (TO)
NUT version: 2.7.4-5
Installation method: from package
UPS device: EATON UPS 5SC 500i , 230V, 350W, 500VA, USB bought in jun 2018
If you connect to TO UPS via USB, the /dev/hidraw0 device will be created.
No any programs from NUT package is not running.
When I run:
/lib/nut/usbhid-ups -a qnapups
Network UPS Tools - Generic HID driver 0.41 (3.10-76-gd2caa7d)
USB communication driver 0.33
kill: No such...
2005 Oct 05
1
NUT does not recognize Effekta MT 1500
...tonups
port = /dev/ttyS0
desc = "Haupt-USV"
And tried to start the driver:
> /usr/local/ups/bin/upsdrvctl start
Network UPS Tools - UPS driver controller 2.0.2
Network UPS Tools - Fenton UPS driver 1.22 (2.0.2)
Unknown ups - please report this ID string: #SMART-UPS 1500VA
T15Q1CCG
Detected Unknown 500VA on /dev/ttyS0
Where did I go wrong?
Should I add some information about the cable I am using?
Is there a way to get it working with the genericups-driver?
(The thing is, I cannot really fool around, there is a very important
server hanging from that ups)...
Thank...
2011 Jan 14
6
Plexus UPS on a QNAP NAS
...;t claim USB device [0001:0000]: could not detach kernel driver from
interface 0: Operation not permitted
Driver failed to start (exit status=1)
My ups.conf looks like this
[qnapups]
driver = usbhid-ups
port = auto
mfr = "Plexus"
model = "Plexus 500VA UPS"
desc = "Workstation"
pollinterval=1
ignoreoff
lsusb shows before the UPS is plugged in
[~] # lsusb
Bus 001 Device 003: ID 04a9:10b0 Canon, Inc.
Bus 001 Device 002: ID 05e3:0608 Genesys Logic, Inc.
Bus 001 Device 001: ID 1d6b:0002
And after
[~]...
2012 May 12
2
NUT for Windows + Eaton/PW 5110
...ve been lead to believe that Eaton is a good Tier 2 UPS vendor (APC
being Tier 1). This microlink business with APC has been driving me away
from them. So I got what I thought would be a good alternative to my
usual APC RS 500's for desktop systems at our remote clients. It is an
Eaton 5110 500VA (103004256-5591).
I also thought it would be a good brand because of what looked like
great support from NUT (green status across the board).
I've been rather disappointed.
* It runs rather hot, ~25F more (128F on the side).
* Lack of battery info (runtime, charge capacity)
* Can't disa...
2007 Jun 01
0
HAL and NUT feedback
...adaptor.present = true (bool)
> battery.charge_level.design = 100 (0x64) (int)
> battery.charge_level.last_full = 100 (0x64) (int)
> battery.charge_level.unit = 'percent' (string)
> battery.is_rechargeable = true (bool)
> battery.model = 'POWERWARE UPS 500VA' (string)
> battery.present = true (bool)
> battery.rechargeable.is_charging = true (bool)
> battery.rechargeable.is_discharging = false (bool)
> battery.reporting.design = 100 (0x64) (int)
> battery.reporting.last_full = 100 (0x64) (int)
> battery.reportin...
2008 Apr 24
1
Unsupported UPS using megatec_usb
...ve thus far determined very little about it. I can run whatever you
like to help identify and work with it. So far I've played around with various settings and have had some limited success with the megatec_usb driver
(Debian testing version):
----ups.conf----
[plexus]
driver=megatec_usb
model=500VA
mfr=Plexus
vendorid=0001
#port=auto
port=/dev/usb/hiddev0
desc="Plexus V 500VA UPS"
----ups.conf----
> $:/lib/nut# ./megatec_usb -a plexus
> Network UPS Tools 2.2.1- - Megatec protocol driver 1.5.9 [megatec_usb]
> Carlos Rodrigues (c) 2003-2007
>
> Serial-over-USB transpo...
2006 Nov 07
6
Sweex 1000VA UPS
...ype=7 driver. But it doesn't.
I get:
mybox:/etc/nut# /etc/init.d/nut start
Starting Network UPS Tools: (upsdrvctl failed).
mybox:/etc/nut#
So I guess I'm using the wrong driver.
I already tried the savenet driver too, but no succes.
I found on the net someone using the ippon driver with a 500VA sweex ups,
but this doesn't work
for me. All help is very appreciated.
Many thanks,
Yves
-------------- next part --------------
An HTML attachment was scrubbed...
URL: http://lists.alioth.debian.org/pipermail/nut-upsuser/attachments/20061107/8d148987/attachment.htm
2007 Jul 25
3
Nut fsd command ignored: bcmxcp_usb driver, Powerware 5105 UPS
...from the UPS.
The bcmxcp_usb driver reports the following status:
# upsc pw3105 at localhost
driver.name: bcmxcp_usb
driver.parameter.port: auto
driver.parameter.shutdown_delay: 120
driver.version: 2.0.5
driver.version.internal: 0.11
input.phases: 1
ups.firmware: 00.80
ups.model: POWERWARE UPS 500VA
ups.power.nominal: 500
ups.serial:
ups.status: OL
ups.voltage.nominal: 240
One peculiarity -- even though the test.battery.start instant command
is listed it puts this in the log:
Jul 24 23:08:11 kea bcmxcp_usb[5221]: [test.battery.start] not supported
Any help would be appreciated.
Cheers, St...
2014 Jun 30
0
Lupus 500 MEC0003 Problems
Sorry for my delay, I've only just read this mail.
At first glance the driver looks like it should work, I will test it
tomorrow (if possible) and let you know.
I'll also give a reply to your questions.
Many thanks for the work you've already put into this.
--------------------------------------------------
From: <hyouko at gmail.com>
Sent: Monday, June 30, 2014 12:42 AM
To:
2014 Feb 15
0
Eaton Powerware 5110 - some stats not reported
...active UPS, Single Phase
ups.firmware: Cont:00.50 Inve:01.50
ups.load: 24
ups.mfr: Eaton
ups.model: POWERWARE UPS 700i
ups.power.nominal: 700
ups.serial:
ups.status: OL
ups.test.result: Done and passed
Happy to do more checks, I see the firmware on my 5110 700VA has the
same values as the 5110 500VA on the wiki, but there are a few fields
different, I guess there is a difference between the wiki page and the
driver in Ubuntu Trusty.
Thanks,
Greg
2019 Jun 07
1
OR500LCDRM1U confirmed working w/ usbhid-ups
I can confirm that CyberPower OR500LCDRM1U works with driver usbhid-ups.
It’s fair to say that the 1000 vA and 1500 vA work as well (the 700 vA variant is already in the compatibility list).
OR500LCDRM1U
OR1000LCDRM1U
OR1500LCDRM1U
Please add them to the compatibility list!
Thanks!
/M
2018 Jul 01
0
No run cmd /usbhid-ups -k !
.../07/2018 11.53, icingaj at gmail.com wrote:
> Good day.
>
> Can not perform shutdowns Ups. Please help.
>
> Details of our installation are:
> OS: Turris Omnia (TO)
> NUT version: 2.7.4-5
> Installation method: from package
> UPS device: EATON UPS 5SC 500i , 230V, 350W, 500VA, USB bought in jun 2018
>
> If you connect to TO UPS via USB, the /dev/hidraw0 device will be created.
> No any programs from NUT package is not running.
>
> When I run:
> /lib/nut/usbhid-ups -a qnapups
> Network UPS Tools - Generic HID driver 0.41 (3.10-76-gd2caa7d)
> USB...
2014 Jun 29
2
Lupus 500 MEC0003 Problems
Sorry for the huge delay and thanks Charles for taking care of this topic.
>> I'm running OpenSuse 13.1 and I have a Lupus 500 USB (Fideltronik)
>>
>> After quite a bit of playing around I managed to get the status of the UPS using the blazer_usb driver and running NUT 2.6.5.
>> But unfortunately none of the Instcmds such as load.off etc. worked.
>
> Can you post
2014 Feb 13
2
Eaton Powerware 5110 - some stats not reported
On Feb 12, 2014, at 7:50 PM, Tim Dawson wrote:
> Run the driver with -DDDDD and see what variables it picks up. I have noted that with the Prestige 9 in bcmxcp, some variables are not consistent within models, and had to do some gentle remapping to get things to work correctly.
Tim, is this the issue you mentioned on 2014-02-02 with blocks 0x9 and 0x13? I'll reply to that email.
> On
2014 Jul 04
2
Lupus 500 MEC0003 Problems
...to test this.
>>> Can you post the output of upsc, and note if any of those values look
>>> wrong?
serwer2:/tmp/nut-fabula # upsc myups
battery.charge: 100
battery.voltage: 13.10
battery.voltage.high: 13.00
battery.voltage.low: 10.40
battery.voltage.nominal: 12.0
device.model: 500VA UPS
device.type: ups
driver.name: nutdrv_qx
driver.parameter.pollfreq: 30
driver.parameter.pollinterval: 2
driver.parameter.port: auto
driver.parameter.productid: 0000
driver.parameter.protocol: megatec
driver.parameter.subdriver: fabula
driver.parameter.vendorid: 0001
driver.version: 2.7.2.5
drive...