search for: 500va

Displaying 20 results from an estimated 34 matches for "500va".

Did you mean: 1500va
2007 Apr 25
1
Re: Sweex UPS 500VA and NUT problem
Arjan, I am forwarding your email to the nut-upsuser mailing list. I am not an expert on the Powermust driver; hopefully somebody on the mailing list will be able to help you! -- Peter Arjan DJ wrote: > > Dear Peter, > Some days ago I bought a Sweex UPS (500VA) and now I have set up NUT (using > the Powermust driver) and everything is working fine. Invoking upsmon -c fsd > gives me a beautifull gracefull shutdown and upsc gives me reliable output. > I have only one problem: when I'm really using the UPS (upsc shows "OB") my > PC...
2005 Oct 03
2
driver for Elite 2005 500VA
Hello, I've just finish a new driver for the Nitram UPS Elite 2005 500VA (compiled and tested with nut-2.0.1 and nut-2.1.0). Currently, all Nitram UPS are made by CyberPower, but the protocol is different than cyberpower.c. I don't have other model to test with, but I think this driver could monitor all Nitram 2005 UPS. I don't have the protocol specificati...
2005 Oct 16
0
Sweex UPS 500VA
Hi, FYI for all whom have the Sweex manageable UPS. I got my sweex manageable UPS500VA working with NetworkUPSTools using the ippon driver. Here is my the ups.conf file: [ups] driver = ippon port = /dev/cuad0 desc = "Server" Has anyone tried the ippon driver with Sweex 600VA, 700VA, and 800VA models? Regards, Jan
2013 Oct 26
1
[HCL] Syndome Era Series 500VA 400W supported by blazer_usb
Syndome Era Series *upsc output* * *battery.charge: 100 battery.runtime: 1000 <-- not reported by UPS (guesstimate) battery.voltage: 13.60 battery.voltage.high: 13.00 battery.voltage.low: 10.40 battery.voltage.nominal: 12.0 device.type: ups driver.flag.novendor: enabled driver.name: blazer_usb driver.parameter.chargetime: 43200 driver.parameter.idleload: 30 driver.parameter.pollinterval: 5
2011 Jan 23
1
Getting a Plexus 500VA to work with NUT
Hi all, First off thanks you for such a great tool - my searching so far indicates that the developers and community behind nut are committed and doing a great job! Background: I've just purchased a Plexus 500VA UPS for ebuyer because it was cheap. I didnt expect much but I've seen a few references to people getting the same and similar models to work with NUT so was encouraged to try! The NUT website compatability chart lists that the blazer_usb driver is the correct one to use. The monitoring server...
2018 Jul 01
2
No run cmd /usbhid-ups -k !
Good day. Can not perform shutdowns Ups. Please help. Details of our installation are: OS: Turris Omnia (TO) NUT version: 2.7.4-5 Installation method: from package UPS device: EATON UPS 5SC 500i , 230V, 350W, 500VA, USB bought in jun 2018 If you connect to TO UPS via USB, the /dev/hidraw0 device will be created. No any programs from NUT package is not running. When I run: /lib/nut/usbhid-ups -a qnapups Network UPS Tools - Generic HID driver 0.41 (3.10-76-gd2caa7d) USB communication driver 0.33 kill: No such...
2005 Oct 05
1
NUT does not recognize Effekta MT 1500
...tonups port = /dev/ttyS0 desc = "Haupt-USV" And tried to start the driver: > /usr/local/ups/bin/upsdrvctl start Network UPS Tools - UPS driver controller 2.0.2 Network UPS Tools - Fenton UPS driver 1.22 (2.0.2) Unknown ups - please report this ID string: #SMART-UPS 1500VA T15Q1CCG Detected Unknown 500VA on /dev/ttyS0 Where did I go wrong? Should I add some information about the cable I am using? Is there a way to get it working with the genericups-driver? (The thing is, I cannot really fool around, there is a very important server hanging from that ups)... Thank...
2011 Jan 14
6
Plexus UPS on a QNAP NAS
...;t claim USB device [0001:0000]: could not detach kernel driver from interface 0: Operation not permitted Driver failed to start (exit status=1) My ups.conf looks like this [qnapups] driver = usbhid-ups port = auto mfr = "Plexus" model = "Plexus 500VA UPS" desc = "Workstation" pollinterval=1 ignoreoff lsusb shows before the UPS is plugged in [~] # lsusb Bus 001 Device 003: ID 04a9:10b0 Canon, Inc. Bus 001 Device 002: ID 05e3:0608 Genesys Logic, Inc. Bus 001 Device 001: ID 1d6b:0002 And after [~]...
2012 May 12
2
NUT for Windows + Eaton/PW 5110
...ve been lead to believe that Eaton is a good Tier 2 UPS vendor (APC being Tier 1). This microlink business with APC has been driving me away from them. So I got what I thought would be a good alternative to my usual APC RS 500's for desktop systems at our remote clients. It is an Eaton 5110 500VA (103004256-5591). I also thought it would be a good brand because of what looked like great support from NUT (green status across the board). I've been rather disappointed. * It runs rather hot, ~25F more (128F on the side). * Lack of battery info (runtime, charge capacity) * Can't disa...
2007 Jun 01
0
HAL and NUT feedback
...adaptor.present = true (bool) > battery.charge_level.design = 100 (0x64) (int) > battery.charge_level.last_full = 100 (0x64) (int) > battery.charge_level.unit = 'percent' (string) > battery.is_rechargeable = true (bool) > battery.model = 'POWERWARE UPS 500VA' (string) > battery.present = true (bool) > battery.rechargeable.is_charging = true (bool) > battery.rechargeable.is_discharging = false (bool) > battery.reporting.design = 100 (0x64) (int) > battery.reporting.last_full = 100 (0x64) (int) > battery.reportin...
2008 Apr 24
1
Unsupported UPS using megatec_usb
...ve thus far determined very little about it. I can run whatever you like to help identify and work with it. So far I've played around with various settings and have had some limited success with the megatec_usb driver (Debian testing version): ----ups.conf---- [plexus] driver=megatec_usb model=500VA mfr=Plexus vendorid=0001 #port=auto port=/dev/usb/hiddev0 desc="Plexus V 500VA UPS" ----ups.conf---- > $:/lib/nut# ./megatec_usb -a plexus > Network UPS Tools 2.2.1- - Megatec protocol driver 1.5.9 [megatec_usb] > Carlos Rodrigues (c) 2003-2007 > > Serial-over-USB transpo...
2006 Nov 07
6
Sweex 1000VA UPS
...ype=7 driver. But it doesn't. I get: mybox:/etc/nut# /etc/init.d/nut start Starting Network UPS Tools: (upsdrvctl failed). mybox:/etc/nut# So I guess I'm using the wrong driver. I already tried the savenet driver too, but no succes. I found on the net someone using the ippon driver with a 500VA sweex ups, but this doesn't work for me. All help is very appreciated. Many thanks, Yves -------------- next part -------------- An HTML attachment was scrubbed... URL: http://lists.alioth.debian.org/pipermail/nut-upsuser/attachments/20061107/8d148987/attachment.htm
2007 Jul 25
3
Nut fsd command ignored: bcmxcp_usb driver, Powerware 5105 UPS
...from the UPS. The bcmxcp_usb driver reports the following status: # upsc pw3105 at localhost driver.name: bcmxcp_usb driver.parameter.port: auto driver.parameter.shutdown_delay: 120 driver.version: 2.0.5 driver.version.internal: 0.11 input.phases: 1 ups.firmware: 00.80 ups.model: POWERWARE UPS 500VA ups.power.nominal: 500 ups.serial: ups.status: OL ups.voltage.nominal: 240 One peculiarity -- even though the test.battery.start instant command is listed it puts this in the log: Jul 24 23:08:11 kea bcmxcp_usb[5221]: [test.battery.start] not supported Any help would be appreciated. Cheers, St...
2014 Jun 30
0
Lupus 500 MEC0003 Problems
Sorry for my delay, I've only just read this mail. At first glance the driver looks like it should work, I will test it tomorrow (if possible) and let you know. I'll also give a reply to your questions. Many thanks for the work you've already put into this. -------------------------------------------------- From: <hyouko at gmail.com> Sent: Monday, June 30, 2014 12:42 AM To:
2014 Feb 15
0
Eaton Powerware 5110 - some stats not reported
...active UPS, Single Phase ups.firmware: Cont:00.50 Inve:01.50 ups.load: 24 ups.mfr: Eaton ups.model: POWERWARE UPS 700i ups.power.nominal: 700 ups.serial: ups.status: OL ups.test.result: Done and passed Happy to do more checks, I see the firmware on my 5110 700VA has the same values as the 5110 500VA on the wiki, but there are a few fields different, I guess there is a difference between the wiki page and the driver in Ubuntu Trusty. Thanks, Greg
2019 Jun 07
1
OR500LCDRM1U confirmed working w/ usbhid-ups
I can confirm that CyberPower OR500LCDRM1U works with driver usbhid-ups. It’s fair to say that the 1000 vA and 1500 vA work as well (the 700 vA variant is already in the compatibility list). OR500LCDRM1U OR1000LCDRM1U OR1500LCDRM1U Please add them to the compatibility list! Thanks! /M
2018 Jul 01
0
No run cmd /usbhid-ups -k !
.../07/2018 11.53, icingaj at gmail.com wrote: > Good day. > > Can not perform shutdowns Ups. Please help. > > Details of our installation are: > OS: Turris Omnia (TO) > NUT version: 2.7.4-5 > Installation method: from package > UPS device: EATON UPS 5SC 500i , 230V, 350W, 500VA, USB bought in jun 2018 > > If you connect to TO UPS via USB, the /dev/hidraw0 device will be created. > No any programs from NUT package is not running. > > When I run: > /lib/nut/usbhid-ups -a qnapups > Network UPS Tools - Generic HID driver 0.41 (3.10-76-gd2caa7d) > USB...
2014 Jun 29
2
Lupus 500 MEC0003 Problems
Sorry for the huge delay and thanks Charles for taking care of this topic. >> I'm running OpenSuse 13.1 and I have a Lupus 500 USB (Fideltronik) >> >> After quite a bit of playing around I managed to get the status of the UPS using the blazer_usb driver and running NUT 2.6.5. >> But unfortunately none of the Instcmds such as load.off etc. worked. > > Can you post
2014 Feb 13
2
Eaton Powerware 5110 - some stats not reported
On Feb 12, 2014, at 7:50 PM, Tim Dawson wrote: > Run the driver with -DDDDD and see what variables it picks up. I have noted that with the Prestige 9 in bcmxcp, some variables are not consistent within models, and had to do some gentle remapping to get things to work correctly. Tim, is this the issue you mentioned on 2014-02-02 with blocks 0x9 and 0x13? I'll reply to that email. > On
2014 Jul 04
2
Lupus 500 MEC0003 Problems
...to test this. >>> Can you post the output of upsc, and note if any of those values look >>> wrong? serwer2:/tmp/nut-fabula # upsc myups battery.charge: 100 battery.voltage: 13.10 battery.voltage.high: 13.00 battery.voltage.low: 10.40 battery.voltage.nominal: 12.0 device.model: 500VA UPS device.type: ups driver.name: nutdrv_qx driver.parameter.pollfreq: 30 driver.parameter.pollinterval: 2 driver.parameter.port: auto driver.parameter.productid: 0000 driver.parameter.protocol: megatec driver.parameter.subdriver: fabula driver.parameter.vendorid: 0001 driver.version: 2.7.2.5 drive...