2019 Jan 22
2
CpberPower PR3000LCDRTXL2UN support
I'm looking at switching from an APC UPS to a different brand after having had my third SU3000RM in a row blow up power transistors. I'm looking at the Cyperpower PR3000LCDRTXL2U. I see the PR3000E and the PR6000LCDRTXL5U listed as supported, but not the PR3000LCDRTXL2U. Howeverit seems likely that if the PR6000LCDRTXL5U is supported, the PR3000LCDRTXL2U ought to work as well. I've
2019 Jan 28
2
Just an interesting data point [CyberPower SNMP]
On 1/27/19 9:13 PM, Charles Lepple wrote: > On Jan 27, 2019, at 2:36 PM, Phil Stracchino <phils at caerllewys.net > <mailto:phils at caerllewys.net>> wrote: >> The new Cyberpower PR3000 (also 3KVA), wqhich operates at a 90% power >> factor, considers this same load to be 43% load. >> >> I wasn't expecting that much of a reduction. > > So... 50%
2018 Mar 10
2
UPS CYBERPOWER CP1300EPFCLCD MISSING FROMCOMPATIBILITY LIST
Hi I have just purchased a Cyberpower CP1300EPFCLCD UPS. It is not listed in your Compatibility List http://networkupstools.org/stable-hcl.html I am very new to all this but do have a background in IT. I have been retired for 18 years so am a bit out of touch so please excuse if I am a bit fuzzy. I will try my best to explain my issue below. When I plug my UPS into my Synology NAS
2018 Sep 27
2
after power outage and proper shutdown, UPS turns on before power returns
Hi, I'm struggling with a peculiar issue with my UPS. After a power outage, the devices powered by it properly shut down via nut. Eventually, the UPS also goes down. Power is still out, however, roughly 40 seconds after the UPS shut down, it turns back on and it starts supplying power to the load, thus turning back on the devices attached to it. This is obviously not something I want. In
2018 Mar 10
0
UPS CYBERPOWER CP1300EPFCLCD MISSING FROMCOMPATIBILITY LIST
...dels seem to have some of the same issues as the PFCLCD models: http://new.networkupstools.org/ddl/Cyber_Power_Systems/CP1500PFCLCD.html There are enough Cyber Power quirks that they get their own category in our issue tracker :-) https://github.com/networkupstools/nut/labels/CyberPower%20%28CPS%29 > Everything works pretty well with the exception of two values. The Battery Voltage should be 24V as it?s a 2 x 12V system connected in series. I'm not sure there's much we can do about this one. The UPS publishes a dummy value (sometimes shows up as 16V, sometimes the same as the...
2019 Jan 23
0
CpberPower PR3000LCDRTXL2UN support
...good chance that the PR3000LCD* models are all supported equally well by the usbhid-ups driver. However, you may want to check the issue list if you are planning to depend on another threshold for shutdown: https://github.com/networkupstools/nut/issues?q=is%3Aissue+is%3Aopen+label%3A%22CyberPower+%28CPS%29%22 Also, you mentioned serial monitoring. I am not as familiar with serial CyberPower models, but take note of the support description here: https://networkupstools.org/docs/man/powerpanel.html#_support_status Most of the serial-connected CPS models have lower compatibility ratings due to thi...
2019 Jan 28
0
Just an interesting data point [CyberPower SNMP/USB]
...-panel USB ports on this server and I now > need three (KVM, GPS receiver, and UPS). You might be lucky with this particular model, but definitely beware of the USB issues I mentioned in another thread: https://github.com/networkupstools/nut/issues?q=is%3Aissue+is%3Aopen+label%3A%22CyberPower+%28CPS%29%22 The output of upsc is sorted alphabetically by key, so it isn't immediately obvious which values come from earlier in the report descriptor. However, after the values for input.transfer.low and input.transfer.high, the other values might end up being scaled to the transfer voltage range....
2019 Dec 17
0
Shutdown time configuration
...sues whose root cause is a disagreement as to how the HID descriptor (and therefore, the HID reports) should be parsed and interpreted. Link to the whole mess (which includes some other non-HID CPS issues): https://github.com/networkupstools/nut/issues?q=is%3Aissue+is%3Aopen+label%3A%22CyberPower+%28CPS%29%22 That said, I don't think that differing load when on/off AC is going to fall into the HID category, but there are certainly a lot of open questions surrounding some of the reported values. As Roger suggested, doing a manual self-test on the batteries may be useful. (I don't know if...
2018 Oct 02
0
after power outage and proper shutdown, UPS turns on before power returns
...ter, but that only comes in play after the power returns, so it > shouldn't apply here. Hi Gabriel, sorry for the delay - I am still working through a bit of a backlog here. We have a few other open CyberPower issues listed here: https://github.com/networkupstools/nut/labels/CyberPower%20%28CPS%29 If you wouldn't mind checking through them to see if the Value line produces similar debug output to the others listed there, that would be most helpful. One theme with some of the CPS timeout issues is that the user-specified timer values are rounded down to the nearest minute. So an offd...
2019 Jan 28
2
Just an interesting data point [CyberPower SNMP/USB]
On 1/27/19 9:49 PM, Charles Lepple wrote: > You might be lucky with this particular model, but definitely beware of the USB issues I mentioned in another thread: > > https://github.com/networkupstools/nut/issues?q=is%3Aissue+is%3Aopen+label%3A%22CyberPower+%28CPS%29%22 > > The output of upsc is sorted alphabetically by key, so it isn't immediately obvious which values come from earlier in the report descriptor. However, after the values for input.transfer.low and input.transfer.high, the other values might end up being scaled to the transfer volt...
2018 Oct 04
2
after power outage and proper shutdown, UPS turns on before power returns
...after the power returns, so it > > shouldn't apply here. > > Hi Gabriel, > > sorry for the delay - I am still working through a bit of a backlog here. > > We have a few other open CyberPower issues listed here: https://github.com/networkupstools/nut/labels/CyberPower%20%28CPS%29 > > If you wouldn't mind checking through them to see if the Value line produces similar debug output to the others listed there, that would be most helpful. To be honest, I'm not really able to read the debug output, so I wouldn't know what to look for (looks like a foreign l...
2017 Sep 11
2
CyberPower UPS Omission
The Hardware Compatibility List page on our website said to report any omissions in the list to this address. I bought a CyberPower UPS Model *LX1500GU*. It looks similar to the *CP1500AVRLCD*. My intention is to configure it in FreeNAS (FreeBSD). The FreeNAS user guide says it uses NUT to provide UPS support an contains a link to your website for a list of drivers of supported UPS devices. I
2017 Sep 28
1
[HCL] CyberPower EC350G supported by usbhid-ups
[shutdown sequence] I have tested and verified the shutdown sequence works. [manufacturor] https://www.cyberpowersystems.com/product/ups/ec350g/ mbeisser at nas:~$ upsc ups Init SSL without certificate database battery.charge: 100 battery.charge.low: 10 battery.charge.warning: 20 battery.mfr.date: CPS battery.runtime: 1575 battery.runtime.low: 300 battery.type: PbAcid battery.voltage: 9.3
2024 Jan 13
1
Cyber Power LE1000DG UPS
I have a Cyber Power LE1000DG UPS I got from Best Buy this weekend. I plan to use it with a TrueNAS scale system, and it is connected via USB. Vendor link: https://www.cyberpowersystems.com/product/ups/battery-backup/le1000dg/. TrueNAS has you pick a UPS driver. I could not find any "LE" related models on https://networkupstools.org/stable-hcl.html (which is the list TrueNAS uses). Per
2018 Mar 10
1
UPS CYBERPOWER CP1300EPFCLCD MISSING FROMCOMPATIBILITY LIST
...stools.org/ddl/Cyber_Power_Systems/CP1500PFCLCD.html> http://new.networkupstools.org/ddl/Cyber_Power_Systems/CP1500PFCLCD.html There are enough Cyber Power quirks that they get their own category in our issue tracker :-) <https://github.com/networkupstools/nut/labels/CyberPower%20%28CPS%29> https://github.com/networkupstools/nut/labels/CyberPower%20%28CPS%29 > Everything works pretty well with the exception of two values. The Battery Voltage should be 24V as it?s a 2 x 12V system connected in series. I'm not sure there's much we can do about this one. The UP...
2018 Oct 04
0
after power outage and proper shutdown, UPS turns on before power returns
...t >>> shouldn't apply here. >> >> Hi Gabriel, >> >> sorry for the delay - I am still working through a bit of a backlog here. >> >> We have a few other open CyberPower issues listed here: https://github.com/networkupstools/nut/labels/CyberPower%20%28CPS%29 >> >> If you wouldn't mind checking through them to see if the Value line produces similar debug output to the others listed there, that would be most helpful. > > To be honest, I'm not really able to read the debug output, so I > wouldn't know what to look for...
2019 Dec 17
2
Shutdown time configuration
On 2019-12-17 06:18, Roger Price wrote: > > I definitely need to check that the vile daemon is present and running. > > In upsmon.conf there are no NOTIFYFLAG declarations, especially for events > ONBATT and LOWBATT. When ONBATT and LOWBATT occur nothing will happen. There > are no NOTIFYMSG declarations and in particular no messages for the ONBATT and > LOWBATT events.
2012 Nov 13
5
Getting information encoded in a SAS, SPSS or Stata command file into R.
Dear folks ? I have a large (26 gig) ASCII flat file in fixed-width format with about 10 million observations of roughly 400 variables. (It is 51 years of Current Population Survey micro data from IPUMS, roughly half the fields for each record). The file was produced by automatic process in response to a data request of mine. The file is not accompanied by a human-readable file giving the
2020 Oct 21
1
Can't get CyberPower UPS to work with Raspberry Pi 4
I've searched the listserv archive, to no avail, so I hope I'm not duplicating a previous problem. I am anxious to get this working, so I'm open to uninstalling what I have and starting over. One note which may not be meaningful is that this UPS pre-dates the Raspberry Pi I've got connected to it, and I used to use it with the CyberPower software, which requires logging in with a
2020 Oct 23
2
Nut-upsuser Digest, Vol 184, Issue 8
...faces, firewall rules are probably a better place to > exclude one or more of the interfaces. > > Note also that the CyberPower UPSes have a number of mostly cosmetic > errors in the output: > https://github.com/networkupstools/nut/issues?q=is%3Aissue+is%3Aopen+label%3A%22CyberPower+%28CPS%29%22 > < > https://github.com/networkupstools/nut/issues?q=is:issue+is:open+label:%22CyberPower+(CPS)%22 > > > > -------------- next part -------------- > An HTML attachment was scrubbed... > URL: < > http://alioth-lists.debian.net/pipermail/nut-upsuser/attachments...