2004 Jun 01
2
Syntax for 2 ISDN Cards
...conf: [interfaces] msn=7501,7502 incomingmsn=* controller=1,2 devices=2,2 Is that correct? I also tried "devices=4". When I try to make 3 simultaneous connections from SIP to ISDN the first and second one works, but on the third connection this happens: -- Executing Dial("SIP/gunnar-26ea", "CAPI/7501:7986:bBYEXTENSION") in new stack chan_capi.c:1147 capi_request: didn't find capi device with outgoing msn = 7501. you should check your config! app_dial.c:673 dial_exec: Unable to create channel of type 'CAPI' == Everyone is busy at this time -- Executing Dia...