Displaying 6 results from an estimated 6 matches for "239.00".
Did you mean:
23.00
2018 Apr 11
2
Unreasonably poor performance of replicated volumes
Hello everybody!
I have 3 gluster servers (*gluster 3.12.6, Centos 7.2*; those are actually
virtual machines located on 3 separate physical XenServer7.1 servers)
They are all connected via infiniband network. Iperf3 shows around *23
Gbit/s network bandwidth *between each 2 of them.
Each server has 3 HDD put into a *stripe*3 thin pool (LVM2) *with logical
volume created on top of it, formatted
2018 Apr 12
0
Unreasonably poor performance of replicated volumes
Guess you went through user lists and tried something like this already
http://lists.gluster.org/pipermail/gluster-users/2018-April/033811.html
I have a same exact setup and below is as far as it went after months of
trail and error.
We all have somewhat same setup and same issue with this - you can find
same post as yours on the daily basis.
On Wed, Apr 11, 2018 at 3:03 PM, Anastasia Belyaeva
2018 Apr 13
1
Unreasonably poor performance of replicated volumes
Thanks a lot for your reply!
You guessed it right though - mailing lists, various blogs, documentation,
videos and even source code at this point. Changing some off the options
does make performance slightly better, but nothing particularly
groundbreaking.
So, if I understand you correctly, no one has yet managed to get acceptable
performance (relative to underlying hardware capabilities) with
2010 Nov 07
2
mean on a plot
Hi, i need to draw a plot with means of values, reading a table from
datafile.
Example of datafile:
Days Weight
0 178.00
0 250.00
0 242.00
0 239.00
0 223.00
0 188.00
0 237.00
0 212.00
0 273.00
0 191.00
0 173.00
0 233.00
0 227.00
0 253.00
0 232.00
4 177.00
4 249.00
4 241.00
4 238.00
4 222.00
4 188.00
4 236.00
4 211.00
4 272.00
4 190.00
4 172.00
4 232.00
4 226.00
4 252.00
4 231.00
if i use
2010 Dec 14
1
Setting Battery Runtime Low
Dear All,
We have an Eaton 9395 UPS, with a ConnectUPS Web/SNMP card.
I've successfully configured NUT to talk to the SNMP card, however it reports a battery.runtime.low of 1 , not much use, how do I change this value, is it defined by the UPS itself, the SNMP card, or NUT ?
Output of upsc below.
Cheers
Stuart
rcs-manage-1:~ # !upsc
upsc phys-eaton
ambient.temperature: 27.0
2016 May 25
1
Slow RAID Check/high %iowait during check after updgrade from CentOS 6.5 -> CentOS 7.2
On 2016-05-25 19:13, Kelly Lesperance wrote:
> Hdparm didn?t get far:
>
> [root at r1k1 ~] # hdparm -tT /dev/sda
>
> /dev/sda:
> Timing cached reads: Alarm clock
> [root at r1k1 ~] #
Hi Kelly,
Try running 'iostat -xdmc 1'. Look for a single drive that has
substantially greater await than ~10msec. If all the drives
except one are taking 6-8msec, but one is very