search for: 20004e00

Displaying 4 results from an estimated 4 matches for "20004e00".

2016 Sep 15
2
blazer_usb MEC0002 problem Fry's Electronics (Turbo-X) [HID PDC?]
Hi again, > On Sep 8, 2016, at 10:05 AM, Vassilis Virvilis <vasvir at iit.demokritos.gr> > wrote: >> Now that's a problem. I am not sure that I can find >> >> 1) the original software >> 2) a (physical) windows machine in the vicinity of the UPS >> Ha! I jumped several hooks but I think I got it. 01. I contacted the store that sold us the UPS and
2016 Sep 16
2
blazer_usb MEC0002 problem Fry's Electronics (Turbo-X) [HID PDC?]
A little deciphering > Looks like the ups always replies > 22 = 16035500 50005300 20004e00 6f002000 41006300 6b00 That is length = 0x16 = 22 type = 0x3 = string Message = "UPS No Ack" Very fun... Regards Vassilis Virvilis
2016 Sep 16
0
blazer_usb MEC0002 problem Fry's Electronics (Turbo-X) [HID PDC?]
Hi again Looks like the ups always replies 22 = 16035500 50005300 20004e00 6f002000 41006300 6b00 The software sends 1) The first time 80 06 0303 4095 0064 100 < 2) The second time with 80 06 030c 4095 0064 100 < 3) The third time with 80 06 030d 4095 0064 100 < 4) repeats step 1) 8 times 5) go to step 2) Regards Vassilis Virvilis
2016 Sep 16
0
blazer_usb MEC0002 problem Fry's Electronics (Turbo-X) [HID PDC?]
On Sep 16, 2016, at 9:38 AM, Vassilis Virvilis wrote: > > A little deciphering > >> Looks like the ups always replies >> 22 = 16035500 50005300 20004e00 6f002000 41006300 6b00 > > That is > length = 0x16 = 22 > type = 0x3 = string > Message = "UPS No Ack" > > Very fun... that string shows up here, among other places: https://github.com/networkupstools/nut/blob/master/drivers/nutdrv_qx.c#L764 but if the upsilon sc...