2010 Feb 28
1
Fw: trouble setting up kebo-1000d ups (usb)
----- Forwarded Message ---- From: Terry Powling <terrypowling at yahoo.co.uk> To: nut-upsuser at lists.alioth.debian.org Sent: Sat, 27 February, 2010 22:30:05 Subject: trouble setting up kebo-1000d ups (usb) Trying to setup Kebo ups-1000D with usb port. lsusb Bus 001 Device 001: ID 1d6b:0001 Linux Foundation 1.1 root hub Bus 001 Device 002: ID 0925:1234 Lakeview Research Bus 002 Device 001: ID 1d6b:0001 Linux Foundation 1.1 root hub Bus 003 Device 001: ID 1d6b:0001 Linux Foundation 1.1 roo...
2015 Apr 09
1
Trouble of setting samba with join AD
...c-sha1-96 aes128-cts-hmac-sha1-96 RC4-HMAC DES-CBC-CRC DES-CBC-MD5 preferred_enctypes = aes256-cts-hmac-sha1-96 aes128-cts-hmac-sha1-96 RC4-HMAC DES-CBC-CRC DES-CBC-MD5 dns_lookup_realm = false dns_lookup_kdc = false forwardable = true renewable = true ticket_lifetime = 365d renew_lifetime = 1000d [realms] TEST.SG = { kdc = 4ecapsvsg6.test.sg:88 admin_server = 4ecapsvsg6.test.sg:749 default_domain = test.sg } [domain_realm] .test.sg = TEST.SG test.sg = TEST.SG [appdefaults] pam = { debug = false forwardable = true renewable = true ticket_lifetime = 365d renew_life...
2014 Aug 08
2
Cyberpower Value1200E might not need 0.667 battery scaling
...r that one Dynex UPS model. We should be able to do a string match, which is ugly, but should work (especially if we default to no scaling). > > Logged: https://github.com/networkupstools/nut/issues/142 It's not just Dynex models - there are some early "UPS VALUE" and "CP 1000D" units that seem to need the correction factor. I'll try to add a check that looks to see if the battery voltage makes sense. -- Charles Lepple clepple at gmail
2005 Sep 19
4
Hardware compatibility list
...Does any body run XEN either 2.0.6/7 or 3.0devel on following machines: 1) nForce4 based motherboard either with single or dual core CPU 2) ASUS 1U server AP140R-E1 --- P4 http://www.asus.com/products4.aspx?modelmenu=2&model=137&l1=9&l2=40&l3=116 3) MICROSTAR Server Barebone K1-1000D (MS-9245) 1U --- Opteron 4) MICROSTAR Server Barebone P1-102A2M (MS-9249) 1U --- P4 5) any HP server 6) any DELL server You info will be greatly appreciated. koxman _______________________________________________ Xen-users mailing list Xen-users@lists.xensource.com http://lists.xensource.c...
2014 Aug 09
0
Cyberpower Value1200E might not need 0.667 battery scaling
...PS model. We should be able to do a string match, which is ugly, but should work (especially if we default to no scaling). >> >> Logged: https://github.com/networkupstools/nut/issues/142 > > It's not just Dynex models - there are some early "UPS VALUE" and "CP 1000D" units that seem to need the correction factor. I'll try to add a check that looks to see if the battery voltage makes sense. Matthew, can you try the attached patch, and run the driver it with -DDDD? https://github.com/networkupstools/nut/commit/c8950dee9c91ce45d05d8f220ea26891fb92329e...
2014 Aug 08
0
Cyberpower Value1200E might not need 0.667 battery scaling
On Aug 7, 2014, at 10:18 PM, Matthew Stapleton <matthew4196 at gmail.com> wrote: > I just got a Cyberpower SOHO Value 1200 ELCD UPS and even with nut 2.7.2, it appears to report battery voltage too low due to the battery scaling function (In drivers/cps-hid.c). Even though the ups has usb id: 0764:0501, UPS.PowerSummary.Voltage reports 26.6 for the 24V batteries so when the 0.667
2015 Apr 06
4
Trouble of setting samba with join AD
Hi Rowland sorry for late reply I've tried as you suggested to download and install, using : wget -cq https://www.samba.org/samba/ftp/samba-latest.tar.gz tar zxf samba-latest.tar.gz cd samba* ./configure && make && make install But after i type #samba -V And #smbclient -V It return an error that samba is not installed -bash: /usr/sbin/samba: No
2014 Aug 08
2
Cyberpower Value1200E might not need 0.667 battery scaling
I just got a Cyberpower SOHO Value 1200 ELCD UPS and even with nut 2.7.2, it appears to report battery voltage too low due to the battery scaling function (In drivers/cps-hid.c). Even though the ups has usb id: 0764:0501, UPS.PowerSummary.Voltage reports 26.6 for the 24V batteries so when the 0.667 battery scale is applied that goes down to 17.7V. upsc output: battery.charge: 100
2014 Aug 11
1
Cyberpower Value1200E might not need 0.667 battery scaling
...del. We should be able to do a string match, which is ugly, but should work (especially if we default to no scaling). >>> >>> Logged: https://github.com/networkupstools/nut/issues/142 >> It's not just Dynex models - there are some early "UPS VALUE" and "CP 1000D" units that seem to need the correction factor. I'll try to add a check that looks to see if the battery voltage makes sense. > Matthew, can you try the attached patch, and run the driver it with -DDDD? > > https://github.com/networkupstools/nut/commit/c8950dee9c91ce45d05d8f220ea2...
2016 Dec 26
6
[Bug 99202] New: system freeze - fifo: SCHED_ERROR 0a [CTXSW_TIMEOUT] - MULTIPLE_WARP_ERRORS - DATA_ERROR 00000004 [INVALID_VALUE] - ILLEGAL_CLASS ch 11 - RT_STORAGE_TYPE_MISMATCH - CLASS_SUBCH_MISMATCH
...bal 00000004 [MULTIPLE_WARP_ERRORS] warp 3c000d [OOR_REG] Dec 18 17:57:52 [kernel] [ 7553.852158] nouveau 0000:03:00.0: gr: TRAP ch 13 [017e107000 MassEffect2.exe[10678]] Dec 18 17:57:52 [kernel] [ 7553.852168] nouveau 0000:03:00.0: gr: GPC0/TPC0/MP trap: global 00000004 [MULTIPLE_WARP_ERRORS] warp 1000d [OOR_REG] Dec 18 17:57:57 [kernel] [ 7558.147983] nouveau 0000:03:00.0: fifo: SCHED_ERROR 0a [CTXSW_TIMEOUT] Dec 18 17:57:57 [kernel] [ 7558.147987] nouveau 0000:03:00.0: fifo: gr engine fault on channel 2, recovering... Dec 18 17:59:01 [CROND] (root) CMD (rm -f /var/spool/cron/lastrun/cron.hourly)...