Displaying 10 results from an estimated 10 matches for "1000d".
Did you mean:
1000
2010 Feb 28
1
Fw: trouble setting up kebo-1000d ups (usb)
----- Forwarded Message ----
From: Terry Powling <terrypowling at yahoo.co.uk>
To: nut-upsuser at lists.alioth.debian.org
Sent: Sat, 27 February, 2010 22:30:05
Subject: trouble setting up kebo-1000d ups (usb)
Trying to setup Kebo ups-1000D with usb port.
lsusb
Bus 001 Device 001: ID 1d6b:0001 Linux Foundation 1.1 root hub
Bus 001 Device 002: ID 0925:1234 Lakeview Research
Bus 002 Device 001: ID 1d6b:0001 Linux Foundation 1.1 root hub
Bus 003 Device 001: ID 1d6b:0001 Linux Foundation 1.1 roo...
2015 Apr 09
1
Trouble of setting samba with join AD
...c-sha1-96 aes128-cts-hmac-sha1-96
RC4-HMAC DES-CBC-CRC DES-CBC-MD5
preferred_enctypes = aes256-cts-hmac-sha1-96 aes128-cts-hmac-sha1-96
RC4-HMAC DES-CBC-CRC DES-CBC-MD5
dns_lookup_realm = false
dns_lookup_kdc = false
forwardable = true
renewable = true
ticket_lifetime = 365d
renew_lifetime = 1000d
[realms]
TEST.SG = {
kdc = 4ecapsvsg6.test.sg:88
admin_server = 4ecapsvsg6.test.sg:749
default_domain = test.sg
}
[domain_realm]
.test.sg = TEST.SG
test.sg = TEST.SG
[appdefaults]
pam = {
debug = false
forwardable = true
renewable = true
ticket_lifetime = 365d
renew_life...
2014 Aug 08
2
Cyberpower Value1200E might not need 0.667 battery scaling
...r that one Dynex UPS model. We should be able to do a string match, which is ugly, but should work (especially if we default to no scaling).
>
> Logged: https://github.com/networkupstools/nut/issues/142
It's not just Dynex models - there are some early "UPS VALUE" and "CP 1000D" units that seem to need the correction factor. I'll try to add a check that looks to see if the battery voltage makes sense.
--
Charles Lepple
clepple at gmail
2005 Sep 19
4
Hardware compatibility list
...Does any body run XEN either 2.0.6/7 or 3.0devel on following machines:
1) nForce4 based motherboard either with single or dual core CPU
2) ASUS 1U server AP140R-E1 --- P4
http://www.asus.com/products4.aspx?modelmenu=2&model=137&l1=9&l2=40&l3=116
3) MICROSTAR Server Barebone K1-1000D (MS-9245) 1U --- Opteron
4) MICROSTAR Server Barebone P1-102A2M (MS-9249) 1U --- P4
5) any HP server
6) any DELL server
You info will be greatly appreciated.
koxman
_______________________________________________
Xen-users mailing list
Xen-users@lists.xensource.com
http://lists.xensource.c...
2014 Aug 09
0
Cyberpower Value1200E might not need 0.667 battery scaling
...PS model. We should be able to do a string match, which is ugly, but should work (especially if we default to no scaling).
>>
>> Logged: https://github.com/networkupstools/nut/issues/142
>
> It's not just Dynex models - there are some early "UPS VALUE" and "CP 1000D" units that seem to need the correction factor. I'll try to add a check that looks to see if the battery voltage makes sense.
Matthew, can you try the attached patch, and run the driver it with -DDDD?
https://github.com/networkupstools/nut/commit/c8950dee9c91ce45d05d8f220ea26891fb92329e...
2014 Aug 08
0
Cyberpower Value1200E might not need 0.667 battery scaling
On Aug 7, 2014, at 10:18 PM, Matthew Stapleton <matthew4196 at gmail.com> wrote:
> I just got a Cyberpower SOHO Value 1200 ELCD UPS and even with nut 2.7.2, it appears to report battery voltage too low due to the battery scaling function (In drivers/cps-hid.c). Even though the ups has usb id: 0764:0501, UPS.PowerSummary.Voltage reports 26.6 for the 24V batteries so when the 0.667
2015 Apr 06
4
Trouble of setting samba with join AD
Hi Rowland sorry for late reply
I've tried as you suggested to download and install, using :
wget -cq https://www.samba.org/samba/ftp/samba-latest.tar.gz
tar zxf samba-latest.tar.gz
cd samba*
./configure && make && make install
But after i type
#samba -V
And
#smbclient -V
It return an error that samba is not installed
-bash: /usr/sbin/samba: No
2014 Aug 08
2
Cyberpower Value1200E might not need 0.667 battery scaling
I just got a Cyberpower SOHO Value 1200 ELCD UPS and even with nut
2.7.2, it appears to report battery voltage too low due to the battery
scaling function (In drivers/cps-hid.c). Even though the ups has usb
id: 0764:0501, UPS.PowerSummary.Voltage reports 26.6 for the 24V
batteries so when the 0.667 battery scale is applied that goes down to
17.7V.
upsc output:
battery.charge: 100
2014 Aug 11
1
Cyberpower Value1200E might not need 0.667 battery scaling
...del. We should be able to do a string match, which is ugly, but should work (especially if we default to no scaling).
>>>
>>> Logged: https://github.com/networkupstools/nut/issues/142
>> It's not just Dynex models - there are some early "UPS VALUE" and "CP 1000D" units that seem to need the correction factor. I'll try to add a check that looks to see if the battery voltage makes sense.
> Matthew, can you try the attached patch, and run the driver it with -DDDD?
>
> https://github.com/networkupstools/nut/commit/c8950dee9c91ce45d05d8f220ea2...
2016 Dec 26
6
[Bug 99202] New: system freeze - fifo: SCHED_ERROR 0a [CTXSW_TIMEOUT] - MULTIPLE_WARP_ERRORS - DATA_ERROR 00000004 [INVALID_VALUE] - ILLEGAL_CLASS ch 11 - RT_STORAGE_TYPE_MISMATCH - CLASS_SUBCH_MISMATCH
...bal 00000004 [MULTIPLE_WARP_ERRORS] warp 3c000d [OOR_REG]
Dec 18 17:57:52 [kernel] [ 7553.852158] nouveau 0000:03:00.0: gr: TRAP ch 13
[017e107000 MassEffect2.exe[10678]]
Dec 18 17:57:52 [kernel] [ 7553.852168] nouveau 0000:03:00.0: gr: GPC0/TPC0/MP
trap: global 00000004 [MULTIPLE_WARP_ERRORS] warp 1000d [OOR_REG]
Dec 18 17:57:57 [kernel] [ 7558.147983] nouveau 0000:03:00.0: fifo: SCHED_ERROR
0a [CTXSW_TIMEOUT]
Dec 18 17:57:57 [kernel] [ 7558.147987] nouveau 0000:03:00.0: fifo: gr engine
fault on channel 2, recovering...
Dec 18 17:59:01 [CROND] (root) CMD (rm -f /var/spool/cron/lastrun/cron.hourly)...