2009 Mar 13
7
Weird Load and Battery Temp Readings
I've acquired and installed NUT 2.4.1 on a D-Link DNS323 NAS. With
exception of Load and Battery Temp readings all works well. A upsc
ups at localhost command returns;
battery.charge: 100
battery.charge.low: 10
battery.charge.warning: 50
battery.date: 2001/09/25
battery.mfr.date: 2008/06/05
battery.runtime: 2122
battery.runtime.low: 120
battery.temperature: 3022999999999998800
battery.type:
2011 Oct 06
1
Differences between USB and serial on an MGE Pulsar Evolution 3000
...90 hid_lookup_usage: found 840024
12.309392 parsing ConfigVoltage
12.309395 Looking up ConfigVoltage
12.309398 hid_lookup_usage: found 840040
12.309400 Path depth = 3
12.309411 0: Usage(00840004)
12.309415 1: Usage(00840024)
12.309417 2: Usage(00840040)
12.309423 entering shut_get_report(id: 08, len: 1800)
12.309426 entering shut_packet_send (8)
12.309429 shut_checksum = b3
12.309435 sent: (11 bytes) => 81 88 a1 01 08 03 00 00 00 18 b3
12.368306 received: 06
12.368317 shut_wait_ack(): ACK received...
2024 Mar 25
0
There is no voltage information
...= 1.39e-06 -> assuming correction factor =
> 1e+07
> 0.280822 send_to_all: SETINFO battery.voltage "13.9"
> 0.280929 hid_lookup_usage: UPS -> 00840004
> 0.281029 hid_lookup_usage: PowerSummary -> 00840024
> 0.281136 hid_lookup_usage: ConfigVoltage -> 00840040
> 0.281249 string_to_path: depth = 3
> 0.281361 Report[buf]: (3 bytes) => 1f 0c 00
> 0.281440 PhyMax = 0, PhyMin = 0, LogMax = 65535, LogMin = 0
> 0.281539 Unit = 00f0d121, UnitExp = -1
> Sorry if it's not useful.
>
> Best regards
>
> Juan Carlos
>
&...
2024 Mar 25
0
There is no voltage information
...= 1.39e-06 -> assuming correction factor =
> 1e+07
> 0.280822 send_to_all: SETINFO battery.voltage "13.9"
> 0.280929 hid_lookup_usage: UPS -> 00840004
> 0.281029 hid_lookup_usage: PowerSummary -> 00840024
> 0.281136 hid_lookup_usage: ConfigVoltage -> 00840040
> 0.281249 string_to_path: depth = 3
> 0.281361 Report[buf]: (3 bytes) => 1f 0c 00
> 0.281440 PhyMax = 0, PhyMin = 0, LogMax = 65535, LogMin = 0
> 0.281539 Unit = 00f0d121, UnitExp = -1
> Sorry if it's not useful.
>
> Best regards
>
> Juan Carlos
>
&...
2007 Jan 26
4
Ablerex 625L USB version
Hi,
Is there any further information on this UPS interface? I have
an Upsonic UPS that is reporting the same interface, but I cannot
make it work or get any sensible information from it.
Thanks
Jon
---
avast! Antivirus: Outbound message clean.
Virus Database (VPS): 000706-2, 25/01/2007
Tested on: 26/01/2007 11:00:14 AM
avast! is copyright (c) 2000-2007 ALWIL Software.
2007 Jan 26
4
Ablerex 625L USB version
Hi,
Is there any further information on this UPS interface? I have
an Upsonic UPS that is reporting the same interface, but I cannot
make it work or get any sensible information from it.
Thanks
Jon
---
avast! Antivirus: Outbound message clean.
Virus Database (VPS): 000706-2, 25/01/2007
Tested on: 26/01/2007 11:00:14 AM
avast! is copyright (c) 2000-2007 ALWIL Software.
2007 Jan 28
0
Fwd: Re: [Nut-upsuser] Ablerex 625L USB version
...Path: 00860004.Flow.FlowID, Type: Feature, ReportID: 0x01, Offset: 0, Size: 4
> parsing 00860004
> parsing Flow
> hid_lookup_usage: found 84001e
> parsing ConfigVoltage
> hid_lookup_usage: found 840040
> Path depth = 3
> 0: Usage(00860004)
> 1: Usage(0084001e)
> 2: Usage(00840040)
> Entering libusb_get_report. ReportSize: 13
> typesafe_control_msg: size: 13
> Can't retrieve Report 1 (75): Value too large for defined data type
> Path: 00860004.Flow.ConfigVoltage, Type: Feature, ReportID: 0x01,
> Offset: 8, Size: 16
>
> Is this correct, or is there so...