2009 Mar 13
7
Weird Load and Battery Temp Readings
I've acquired and installed NUT 2.4.1 on a D-Link DNS323 NAS. With
exception of Load and Battery Temp readings all works well. A upsc
ups at localhost command returns;
battery.charge: 100
battery.charge.low: 10
battery.charge.warning: 50
battery.date: 2001/09/25
battery.mfr.date: 2008/06/05
battery.runtime: 2122
battery.runtime.low: 120
battery.temperature: 3022999999999998800
battery.type:
2006 Feb 27
1
MGE Nova 1100 using newhidups on netBSD 3.0
...found 840017
Path depth = 3
0: UPage(84), Usage(4)
1: UPage(84), Usage(16)
2: UPage(84), Usage(17)
Entering libusb_get_report
Can't retrieve Report 11 (-5/5): Input/output error
Path: UPS.PowerConverter.PowerConverterID, Type: Feature
Looking up 00840004
Looking up 00840016
Looking up 0084001c
Looking up 0084001d
entering string_to_path()
parsing UPS
Looking up UPS
hid_lookup_usage: found 840004
parsing PowerConverter
Looking up PowerConverter
hid_lookup_usage: found 840016
parsing Output
Looking up Output
hid_lookup_usage: found 84001c
parsing 0084001d
Looking up 0084001d...
2011 Oct 06
1
Differences between USB and serial on an MGE Pulsar Evolution 3000
...t
12.207411 hid_lookup_usage: found 84001c
12.207414 parsing Voltage
12.207416 Looking up Voltage
12.207419 hid_lookup_usage: found 840030
12.207422 Path depth = 4
12.207425 0: Usage(00840004)
12.207427 1: Usage(00840016)
12.207430 2: Usage(0084001c)
12.207433 3: Usage(00840030)
12.207438 entering shut_get_report(id: 12, len: 1800)
12.207441 entering shut_packet_send (8)
12.207444 shut_checksum = a9
12.207449 sent: (11 bytes) => 81 88 a1 01 12 03 00 00 00 18 a9
12.263301 received: 06
12.263310...
2024 Mar 25
0
There is no voltage information
...t: 0, Size: 16, Value: 2.201e-05
> 0.278274 Input/OutputVoltage = 2.201e-05 -> assuming correction factor
> = 1e+07
> 0.278384 send_to_all: SETINFO input.voltage "220.1"
> 0.278517 hid_lookup_usage: UPS -> 00840004
> 0.278621 hid_lookup_usage: Output -> 0084001c
> 0.278769 hid_lookup_usage: Voltage -> 00840030
> 0.278913 string_to_path: depth = 3
> 0.279025 Report[buf]: (3 bytes) => 2b 9e 08
> 0.279133 PhyMax = 0, PhyMin = 0, LogMax = 65535, LogMin = 0
> 0.279240 Unit = 00f0d121, UnitExp = -1
> 0.279304 Exponent =...
2024 Mar 25
0
There is no voltage information
...t: 0, Size: 16, Value: 2.201e-05
> 0.278274 Input/OutputVoltage = 2.201e-05 -> assuming correction factor
> = 1e+07
> 0.278384 send_to_all: SETINFO input.voltage "220.1"
> 0.278517 hid_lookup_usage: UPS -> 00840004
> 0.278621 hid_lookup_usage: Output -> 0084001c
> 0.278769 hid_lookup_usage: Voltage -> 00840030
> 0.278913 string_to_path: depth = 3
> 0.279025 Report[buf]: (3 bytes) => 2b 9e 08
> 0.279133 PhyMax = 0, PhyMin = 0, LogMax = 65535, LogMin = 0
> 0.279240 Unit = 00f0d121, UnitExp = -1
> 0.279304 Exponent =...