Displaying 9 results from an estimated 9 matches for "0020b".
Did you mean:
0020
2019 Aug 28
2
Debian 10 nut 2.7.4-8 and APC Back UPS 600i on 940-0020B
...h upsc APC600
I was switch to battery, after 2-3 second it show that is on battery OB
and after it shutdown because of low battery LO.
I think that systemd scripts some what unsynchronized, but after it connect.
Problem still exist - why low battery?
Low battery sensing is a little tricky on 940-0020B it using DCD as input,
but it driven by CTS and TxD too. I'm afraid that I cannot using -DCD
setting.
Any suggestion?
tovis
> On 28.08.19 12:54, tovis r-visor wrote:
>>I'm using nut for many years on my home "server" without problems running
>>on Debian 6.x nut v...
2019 Aug 28
0
Debian 10 nut 2.7.4-8 and APC Back UPS 600i on 940-0020B
On 28.08.19 12:54, tovis r-visor wrote:
>I'm using nut for many years on my home "server" without problems running
>on Debian 6.x nut version 2.4.3
>Now I have decided to move to Debian 10. I have started from zero and
>install new system on a different disk. I have successfully installed new
>nut version 2.7.4
>Aug 27 16:52:53 nusi upsd[506]: fopen
2019 Aug 28
0
Debian 10 nut 2.7.4-8 and APC Back UPS 600i on 940-0020B
On Wed, 28 Aug 2019, tovis r-visor wrote:
> I was switch to battery, after 2-3 second it show that is on battery OB
> and after it shutdown because of low battery LO.
I wondered how old is your battery ?
Roger
2019 Sep 08
1
Debian 10 nut 2.7.4-8 and APC Back UPS 600i on 940-0020B
> On Wed, 28 Aug 2019, tovis r-visor wrote:
>> I was switch to battery, after 2-3 second it show that is on battery OB
and after it shutdown because of low battery LO.
> I wondered how old is your battery ?
> Roger
> I have change it 2019.03.08. 12V/10Ah YUASA.
> I was checked not only battery voltage (13.6V without load), but
charging > voltage and output voltage using
2019 Sep 11
0
Debian 10 nut 2.7.4-8 and APC Back UPS 600i on 940-0020B
On Sep 11, 2019, at 5:25 AM, tovis r-visor <tovis at r-visor.hu> wrote:
>
> I does not change any of them. Simple, after boot, using
> $ watch upsc MYUPS
> what is give me "LB OL"
> from another terminal I restart:
> # systemctl restart nut-driver.service
> after some seconds the status is changed to simply "OL".
Are there any systemd units that
2019 Sep 11
2
Debian 10 nut 2.7.4-8 and APC Back UPS 600i on 940-0020B
> On Sun, 8 Sep 2019, tovis r-visor wrote:
>
>> After long struggling, check every parts of UPS and cable, I have realized
>> that is after boot I reload the driver the system work well:
>> # systemctl restart nut-driver.service
>> I was checked up to real "battery low" and shutdown, switch off the UPS
every thing goes well.
>> I was activated
2019 Aug 28
2
Debian 10 nut 2.7.4-8 and APC Back UPS 600i on 940-0020B
...ian 10. I have started from zero and
install new system on a different disk. I have successfully installed new
nut version 2.7.4
I've found one issue, that new version see always "low battery" state.
Excerpt from syslog:
Aug 27 16:52:52 nusi upsdrvctl[501]: UPS type: APC Back-UPS (940-0020B/C
cable)
Aug 27 16:52:52 nusi upsdrvctl[501]: parse_input_signals: input overrides
specified, but no effective difference - check for typos?
Aug 27 16:52:52 nusi upsdrvctl[501]: Network UPS Tools - UPS driver
controller 2.7.4
Aug 27 16:52:53 nusi upsd[506]: fopen /var/run/nut/upsd.pid: No such file...
2005 Aug 08
1
Here are CORRECT APC cable diagrams
...E-GND |
| |
+-----------------------------------------------------------------+
+-----------------------------------------------------------------+
| |
| Gray APC 940-0020B Simple Signalling UPS Cable Wiring Diagram |
| This information is verified and tested to be 100% correct. |
| |
+-----------------------------------------------------------------+
|...
2009 Mar 28
1
APCUPSD port 3551 permission problem
...racters or less.
#UPSNAME
# UPSCABLE <cable>
# Defines the type of cable connecting the UPS to your computer.
#
# Possible generic choices for <cable> are:
# simple, smart, ether, usb
#
# Or a specific cable model number may be used:
# 940-0119A, 940-0127A, 940-0128A, 940-0020B,
# 940-0020C, 940-0023A, 940-0024B, 940-0024C,
# 940-1524C, 940-0024G, 940-0095A, 940-0095B,
# 940-0095C, M-04-02-2000
#
#UPSCABLE smart
UPSCABLE usb
# To get apcupsd to work, in addition to defining the cable
# above, you must also define a UPSTYPE, which corresponds to
# the type of...