Tripp-Lite BCPERS450 shutdown/restart problems
On Dec 20, 2017, at 10:32 AM, Ken Olum wrote:
>
> 0.090564 find_nut_info: unknown info type: load.on.delay
> 0.090577 find_nut_info: unknown info type: load.on.delay
> 0.090585 Initiating UPS shutdown
> 0.090593 upsdrv_shutdown...
> 0.090601 instcmd(shutdown.return, [NULL])
> 0.090614 find_nut_info: unknown info type: shutdown.return
> 0.090624
2017 Dec 20
3
Tripp-Lite BCPERS450 shutdown/restart problems
Thanks for your help.
From: Charles Lepple <clepple at gmail.com>
Date: Mon, 18 Dec 2017 19:26:56 -0500
This may sound like an apples-to-oranges comparison, but we did uncover an issue with CyberPower UPSes where the delay values needed to be greater than or equal to 60 (seconds), since they were being rounded down to integer numbers of minutes internally:
What was the largest
2017 Dec 18
2
Tripp-Lite BCPERS450 shutdown/restart problems
I have a Tripp-Lite BCPERS450, connected to a system running Ubuntu
16.04.3 LTS and NUT 2.7.2-4ubuntu1.2. I had to make my own
/lib/systemd/system-shutdown/nutshutdown, but now everything is working
except for powering on and off the UPS. Regardless of the settings of
offdelay and ondelay in upsconf, and regardless of whether the AC power
is on, when I say "upsdrvctl shutdown" the UPS