Charles Lepple
2018-Feb-26 13:56 UTC
[Nut-upsdev] [networkupstools/nut] Riello IDG400 wrong values & not powering off (#530)
On Feb 26, 2018, at 4:58 AM, Elio Parisi <e.parisi at riello-ups.com> wrote:> > Hi Charles, > this type of UPS doesn't support realtime autonomy calculation, instead a fixed countdown must be used. > > How we can fix non supported values?If a value is not supported, the driver should not publish it with the dstate API. Dhould the driver be modified to not return battery.charge if the UPS returns 0xFF? Are there other variables that are affected? (I don't think the IDG400 is covered in the protocol documentation that the NUT project received a while back.)> > For the point number 2, as we know NUT perfomrs the shutdown after battery low signal with a delay of 5 seconds as specified in the FINALDELAY. > Is this correct?Right, NUT tells the computer to shut down, but it also typically sends a shutdown signal to the UPS. Does the IDG400 also respond to the same shutdown command as others?
Elio Parisi
2018-Feb-26 17:06 UTC
[Nut-upsdev] R: [networkupstools/nut] Riello IDG400 wrong values & not powering off (#530)
Hi Charles, attached there is a patch for a new version of riello drivers: Changes: - small changes in riello_usb.c and riello_ser that solved problem with UPS that not support realtime autonomy calculation (and also internal temperature); - the second problem I think is related to the first because the shutdown command that I sent to UPS by NUT monitor works without problems; Cheers, Elio Parisi. -----Messaggio originale----- Da: Charles Lepple [mailto:clepple at gmail.com] Inviato: luned? 26 febbraio 2018 14:56 A: Elio Parisi <E.Parisi at riello-ups.com> Cc: nut-upsdev Nut Developer Mailing List <nut-upsdev at lists.alioth.debian.org> Oggetto: Re: [networkupstools/nut] Riello IDG400 wrong values & not powering off (#530) On Feb 26, 2018, at 4:58 AM, Elio Parisi <e.parisi at riello-ups.com> wrote:> > Hi Charles, > this type of UPS doesn't support realtime autonomy calculation, instead a fixed countdown must be used. > > How we can fix non supported values?If a value is not supported, the driver should not publish it with the dstate API. Dhould the driver be modified to not return battery.charge if the UPS returns 0xFF? Are there other variables that are affected? (I don't think the IDG400 is covered in the protocol documentation that the NUT project received a while back.)> > For the point number 2, as we know NUT perfomrs the shutdown after battery low signal with a delay of 5 seconds as specified in the FINALDELAY. > Is this correct?Right, NUT tells the computer to shut down, but it also typically sends a shutdown signal to the UPS. Does the IDG400 also respond to the same shutdown command as others? -------------- next part -------------- A non-text attachment was scrubbed... Name: riello.diff.gz Type: application/x-gzip Size: 593 bytes Desc: riello.diff.gz URL: <http://lists.alioth.debian.org/pipermail/nut-upsdev/attachments/20180226/fb06b665/attachment.bin>
Charles Lepple
2018-Mar-07 00:26 UTC
[Nut-upsdev] [networkupstools/nut] Riello IDG400 wrong values & not powering off (#530)
On Feb 26, 2018, at 12:06 PM, Elio Parisi <e.parisi at riello-ups.com> wrote:> - the second problem I think is related to the first because the shutdown command that I sent to UPS by NUT monitor works without problems;Can you please weigh in on the discussion on GitHub? https://github.com/networkupstools/nut/issues/530#issuecomment-370947318
Apparently Analagous Threads
- R: [networkupstools/nut] Riello IDG400 wrong values & not powering off (#530)
- Fwd: [networkupstools/nut] Riello IDG400 wrong values & not powering off (#530)
- New version of riello driver
- Small fixes needed for Riello driver
- Small fixes needed for Riello driver