Lyonn CTB-1200
root at frambuesa:~# upsc lyonn at localhost
battery.voltage: 27.20
battery.voltage.nominal: 24.0
beeper.status: enabled
device.type: ups
driver.name: blazer_usb
driver.parameter.pollinterval: 2
driver.parameter.port: auto
driver.version: 2.4.3
driver.version.internal: 0.03
input.current.nominal: 5.0
input.frequency: 49.9
input.frequency.nominal: 50
input.voltage: 213.3
input.voltage.fault: 213.3
input.voltage.nominal: 220
output.voltage: 213.8
ups.delay.shutdown: 30
ups.delay.start: 180
ups.load: 10
ups.productid: 5161
ups.status: OL
ups.type: offline / line interactive
ups.vendorid: 0665
I'm not sure what you expect with "shutdown sequence testing
results"
("it worked ok", or something else? :)
Thanks for all your work!
Arnaud Quette
2012-Dec-19 22:04 UTC
[Nut-upsdev] [HCL] Lyonn CTB-1200 supported by blazer_usb
Hi Martin 2012/12/14 Martin Sarsale | Properati <martin at properati.com>> Lyonn CTB-1200 > > root at frambuesa:~# upsc lyonn at localhost > battery.voltage: 27.20 > battery.voltage.nominal: 24.0 > beeper.status: enabled > device.type: ups > driver.name: blazer_usb > driver.parameter.pollinterval: 2 > driver.parameter.port: auto > driver.version: 2.4.3 > driver.version.internal: 0.03 > input.current.nominal: 5.0 > input.frequency: 49.9 > input.frequency.nominal: 50 > input.voltage: 213.3 > input.voltage.fault: 213.3 > input.voltage.nominal: 220 > output.voltage: 213.8 > ups.delay.shutdown: 30 > ups.delay.start: 180 > ups.load: 10 > ups.productid: 5161 > ups.status: OL > ups.type: offline / line interactive > ups.vendorid: 0665 > > > I'm not sure what you expect with "shutdown sequence testing results" > ("it worked ok", or something else? :) >a statement that it indeed work, as per the shutdown procedure, is enough. after all, if it crashes the protected system, you'll probably be the first victim ;) I've just committed a clarified wording (r3835) to make it more obvious, thanks: http://trac.networkupstools.org/projects/nut/changeset/3835 before adding a new entry to the HCL, could you please point us at the manufacturer website? all I can find is solytec.com.ar, and no special refs apart from tags/meta! Thanks for all your work!>thanks for the thanks ;) cheers, Arno -- NUT (Network UPS Tools) Project Leader - http://www.networkupstools.org Debian Developer - http://www.debian.org Free Software Developer - http://arnaud.quette.fr -------------- next part -------------- An HTML attachment was scrubbed... URL: <http://lists.alioth.debian.org/pipermail/nut-upsdev/attachments/20121219/c2065acf/attachment.html>