Stefan Hajnoczi
2017-Jul-26 14:32 UTC
[PATCH] virtio_blk: fix incorrect message when disk is resized
The message printed on disk resize is incorrect. The following is
printed when resizing to 2 GiB:
$ truncate -s 1G test.img
$ qemu -device virtio-blk-pci,logical_block_size=4096,...
(qemu) block_resize drive1 2G
virtio_blk virtio0: new size: 4194304 4096-byte logical blocks (17.2 GB/16.0
GiB)
The virtio_blk capacity config field is in 512-byte sector units
regardless of logical_block_size as per the VIRTIO specification.
Therefore the message should read:
virtio_blk virtio0: new size: 524288 4096-byte logical blocks (2.15 GB/2.0
GiB)
Note that this only affects the printed message. Thankfully the actual
block device has the correct size because the block layer expects
capacity in sectors.
Signed-off-by: Stefan Hajnoczi <stefanha at redhat.com>
---
drivers/block/virtio_blk.c | 16 ++++++++++------
1 file changed, 10 insertions(+), 6 deletions(-)
diff --git a/drivers/block/virtio_blk.c b/drivers/block/virtio_blk.c
index 4e02aa5fdac0..69a2d1748743 100644
--- a/drivers/block/virtio_blk.c
+++ b/drivers/block/virtio_blk.c
@@ -381,6 +381,7 @@ static void virtblk_config_changed_work(struct work_struct
*work)
struct request_queue *q = vblk->disk->queue;
char cap_str_2[10], cap_str_10[10];
char *envp[] = { "RESIZE=1", NULL };
+ unsigned long long nblocks;
u64 capacity;
/* Host must always specify the capacity. */
@@ -393,16 +394,19 @@ static void virtblk_config_changed_work(struct work_struct
*work)
capacity = (sector_t)-1;
}
- string_get_size(capacity, queue_logical_block_size(q),
+ nblocks = DIV_ROUND_UP_ULL(capacity, queue_logical_block_size(q) >> 9);
+
+ string_get_size(nblocks, queue_logical_block_size(q),
STRING_UNITS_2, cap_str_2, sizeof(cap_str_2));
- string_get_size(capacity, queue_logical_block_size(q),
+ string_get_size(nblocks, queue_logical_block_size(q),
STRING_UNITS_10, cap_str_10, sizeof(cap_str_10));
dev_notice(&vdev->dev,
- "new size: %llu %d-byte logical blocks (%s/%s)\n",
- (unsigned long long)capacity,
- queue_logical_block_size(q),
- cap_str_10, cap_str_2);
+ "new size: %llu %d-byte logical blocks (%s/%s)\n",
+ nblocks,
+ queue_logical_block_size(q),
+ cap_str_10,
+ cap_str_2);
set_capacity(vblk->disk, capacity);
revalidate_disk(vblk->disk);
--
2.13.3
Stefan Hajnoczi
2017-Aug-04 09:37 UTC
[PATCH] virtio_blk: fix incorrect message when disk is resized
On Wed, Jul 26, 2017 at 03:32:23PM +0100, Stefan Hajnoczi wrote:> The message printed on disk resize is incorrect. The following is > printed when resizing to 2 GiB: > > $ truncate -s 1G test.img > $ qemu -device virtio-blk-pci,logical_block_size=4096,... > (qemu) block_resize drive1 2G > > virtio_blk virtio0: new size: 4194304 4096-byte logical blocks (17.2 GB/16.0 GiB) > > The virtio_blk capacity config field is in 512-byte sector units > regardless of logical_block_size as per the VIRTIO specification. > Therefore the message should read: > > virtio_blk virtio0: new size: 524288 4096-byte logical blocks (2.15 GB/2.0 GiB) > > Note that this only affects the printed message. Thankfully the actual > block device has the correct size because the block layer expects > capacity in sectors. > > Signed-off-by: Stefan Hajnoczi <stefanha at redhat.com> > --- > drivers/block/virtio_blk.c | 16 ++++++++++------ > 1 file changed, 10 insertions(+), 6 deletions(-)Ping?> diff --git a/drivers/block/virtio_blk.c b/drivers/block/virtio_blk.c > index 4e02aa5fdac0..69a2d1748743 100644 > --- a/drivers/block/virtio_blk.c > +++ b/drivers/block/virtio_blk.c > @@ -381,6 +381,7 @@ static void virtblk_config_changed_work(struct work_struct *work) > struct request_queue *q = vblk->disk->queue; > char cap_str_2[10], cap_str_10[10]; > char *envp[] = { "RESIZE=1", NULL }; > + unsigned long long nblocks; > u64 capacity; > > /* Host must always specify the capacity. */ > @@ -393,16 +394,19 @@ static void virtblk_config_changed_work(struct work_struct *work) > capacity = (sector_t)-1; > } > > - string_get_size(capacity, queue_logical_block_size(q), > + nblocks = DIV_ROUND_UP_ULL(capacity, queue_logical_block_size(q) >> 9); > + > + string_get_size(nblocks, queue_logical_block_size(q), > STRING_UNITS_2, cap_str_2, sizeof(cap_str_2)); > - string_get_size(capacity, queue_logical_block_size(q), > + string_get_size(nblocks, queue_logical_block_size(q), > STRING_UNITS_10, cap_str_10, sizeof(cap_str_10)); > > dev_notice(&vdev->dev, > - "new size: %llu %d-byte logical blocks (%s/%s)\n", > - (unsigned long long)capacity, > - queue_logical_block_size(q), > - cap_str_10, cap_str_2); > + "new size: %llu %d-byte logical blocks (%s/%s)\n", > + nblocks, > + queue_logical_block_size(q), > + cap_str_10, > + cap_str_2); > > set_capacity(vblk->disk, capacity); > revalidate_disk(vblk->disk); > -- > 2.13.3 >-------------- next part -------------- A non-text attachment was scrubbed... Name: signature.asc Type: application/pgp-signature Size: 455 bytes Desc: not available URL: <http://lists.linuxfoundation.org/pipermail/virtualization/attachments/20170804/15e3f096/attachment-0001.sig>
Michael S. Tsirkin
2017-Aug-04 13:24 UTC
[PATCH] virtio_blk: fix incorrect message when disk is resized
On Fri, Aug 04, 2017 at 10:37:54AM +0100, Stefan Hajnoczi wrote:> On Wed, Jul 26, 2017 at 03:32:23PM +0100, Stefan Hajnoczi wrote: > > The message printed on disk resize is incorrect. The following is > > printed when resizing to 2 GiB: > > > > $ truncate -s 1G test.img > > $ qemu -device virtio-blk-pci,logical_block_size=4096,... > > (qemu) block_resize drive1 2G > > > > virtio_blk virtio0: new size: 4194304 4096-byte logical blocks (17.2 GB/16.0 GiB) > > > > The virtio_blk capacity config field is in 512-byte sector units > > regardless of logical_block_size as per the VIRTIO specification. > > Therefore the message should read: > > > > virtio_blk virtio0: new size: 524288 4096-byte logical blocks (2.15 GB/2.0 GiB) > > > > Note that this only affects the printed message. Thankfully the actual > > block device has the correct size because the block layer expects > > capacity in sectors. > > > > Signed-off-by: Stefan Hajnoczi <stefanha at redhat.com> > > --- > > drivers/block/virtio_blk.c | 16 ++++++++++------ > > 1 file changed, 10 insertions(+), 6 deletions(-) > > Ping?Oops - I thought I sent it up. Will do.> > diff --git a/drivers/block/virtio_blk.c b/drivers/block/virtio_blk.c > > index 4e02aa5fdac0..69a2d1748743 100644 > > --- a/drivers/block/virtio_blk.c > > +++ b/drivers/block/virtio_blk.c > > @@ -381,6 +381,7 @@ static void virtblk_config_changed_work(struct work_struct *work) > > struct request_queue *q = vblk->disk->queue; > > char cap_str_2[10], cap_str_10[10]; > > char *envp[] = { "RESIZE=1", NULL }; > > + unsigned long long nblocks; > > u64 capacity; > > > > /* Host must always specify the capacity. */ > > @@ -393,16 +394,19 @@ static void virtblk_config_changed_work(struct work_struct *work) > > capacity = (sector_t)-1; > > } > > > > - string_get_size(capacity, queue_logical_block_size(q), > > + nblocks = DIV_ROUND_UP_ULL(capacity, queue_logical_block_size(q) >> 9); > > + > > + string_get_size(nblocks, queue_logical_block_size(q), > > STRING_UNITS_2, cap_str_2, sizeof(cap_str_2)); > > - string_get_size(capacity, queue_logical_block_size(q), > > + string_get_size(nblocks, queue_logical_block_size(q), > > STRING_UNITS_10, cap_str_10, sizeof(cap_str_10)); > > > > dev_notice(&vdev->dev, > > - "new size: %llu %d-byte logical blocks (%s/%s)\n", > > - (unsigned long long)capacity, > > - queue_logical_block_size(q), > > - cap_str_10, cap_str_2); > > + "new size: %llu %d-byte logical blocks (%s/%s)\n", > > + nblocks, > > + queue_logical_block_size(q), > > + cap_str_10, > > + cap_str_2); > > > > set_capacity(vblk->disk, capacity); > > revalidate_disk(vblk->disk); > > -- > > 2.13.3 > >
Maybe Matching Threads
- [PATCH] virtio_blk: fix incorrect message when disk is resized
- [PATCH] virtio_blk: fix incorrect message when disk is resized
- [PATCH] virtio_blk: print capacity at probe time
- [PATCH] sd, mmc, virtio_blk, string_helpers: fix block size units
- [PATCH] sd, mmc, virtio_blk, string_helpers: fix block size units