[PATCH] virtio_blk: fix incorrect message when disk is resized
The message printed on disk resize is incorrect. The following is printed when resizing to 2 GiB: $ truncate -s 1G test.img $ qemu -device virtio-blk-pci,logical_block_size=4096,... (qemu) block_resize drive1 2G virtio_blk virtio0: new size: 4194304 4096-byte logical blocks (17.2 GB/16.0 GiB) The virtio_blk capacity config field is in 512-byte sector units regardless of logical_block_size as per the VIRTIO specification. Therefore the message should read: virtio_blk virtio0: new size: 524288 4096-byte logical blocks (2.15 GB/2.0 GiB) Note that this only affects the printed message. Thankfully the actual block device has the correct size because the block layer expects capacity in sectors. Signed-off-by: Stefan Hajnoczi <stefanha at redhat.com> --- drivers/block/virtio_blk.c | 16 ++++++++++------ 1 file changed, 10 insertions(+), 6 deletions(-) diff --git a/drivers/block/virtio_blk.c b/drivers/block/virtio_blk.c index 4e02aa5fdac0..69a2d1748743 100644 --- a/drivers/block/virtio_blk.c +++ b/drivers/block/virtio_blk.c @@ -381,6 +381,7 @@ static void virtblk_config_changed_work(struct work_struct *work) struct request_queue *q = vblk->disk->queue; char cap_str_2[10], cap_str_10[10]; char *envp[] = { "RESIZE=1", NULL }; + unsigned long long nblocks; u64 capacity; /* Host must always specify the capacity. */ @@ -393,16 +394,19 @@ static void virtblk_config_changed_work(struct work_struct *work) capacity = (sector_t)-1; } - string_get_size(capacity, queue_logical_block_size(q), + nblocks = DIV_ROUND_UP_ULL(capacity, queue_logical_block_size(q) >> 9); + + string_get_size(nblocks, queue_logical_block_size(q), STRING_UNITS_2, cap_str_2, sizeof(cap_str_2)); - string_get_size(capacity, queue_logical_block_size(q), + string_get_size(nblocks, queue_logical_block_size(q), STRING_UNITS_10, cap_str_10, sizeof(cap_str_10)); dev_notice(&vdev->dev, - "new size: %llu %d-byte logical blocks (%s/%s)\n", - (unsigned long long)capacity, - queue_logical_block_size(q), - cap_str_10, cap_str_2); + "new size: %llu %d-byte logical blocks (%s/%s)\n", + nblocks, + queue_logical_block_size(q), + cap_str_10, + cap_str_2); set_capacity(vblk->disk, capacity); revalidate_disk(vblk->disk); -- 2.13.3
Stefan Hajnoczi
2017-Aug-04 09:37 UTC
[PATCH] virtio_blk: fix incorrect message when disk is resized
On Wed, Jul 26, 2017 at 03:32:23PM +0100, Stefan Hajnoczi wrote:> The message printed on disk resize is incorrect. The following is > printed when resizing to 2 GiB: > > $ truncate -s 1G test.img > $ qemu -device virtio-blk-pci,logical_block_size=4096,... > (qemu) block_resize drive1 2G > > virtio_blk virtio0: new size: 4194304 4096-byte logical blocks (17.2 GB/16.0 GiB) > > The virtio_blk capacity config field is in 512-byte sector units > regardless of logical_block_size as per the VIRTIO specification. > Therefore the message should read: > > virtio_blk virtio0: new size: 524288 4096-byte logical blocks (2.15 GB/2.0 GiB) > > Note that this only affects the printed message. Thankfully the actual > block device has the correct size because the block layer expects > capacity in sectors. > > Signed-off-by: Stefan Hajnoczi <stefanha at redhat.com> > --- > drivers/block/virtio_blk.c | 16 ++++++++++------ > 1 file changed, 10 insertions(+), 6 deletions(-)Ping?> diff --git a/drivers/block/virtio_blk.c b/drivers/block/virtio_blk.c > index 4e02aa5fdac0..69a2d1748743 100644 > --- a/drivers/block/virtio_blk.c > +++ b/drivers/block/virtio_blk.c > @@ -381,6 +381,7 @@ static void virtblk_config_changed_work(struct work_struct *work) > struct request_queue *q = vblk->disk->queue; > char cap_str_2[10], cap_str_10[10]; > char *envp[] = { "RESIZE=1", NULL }; > + unsigned long long nblocks; > u64 capacity; > > /* Host must always specify the capacity. */ > @@ -393,16 +394,19 @@ static void virtblk_config_changed_work(struct work_struct *work) > capacity = (sector_t)-1; > } > > - string_get_size(capacity, queue_logical_block_size(q), > + nblocks = DIV_ROUND_UP_ULL(capacity, queue_logical_block_size(q) >> 9); > + > + string_get_size(nblocks, queue_logical_block_size(q), > STRING_UNITS_2, cap_str_2, sizeof(cap_str_2)); > - string_get_size(capacity, queue_logical_block_size(q), > + string_get_size(nblocks, queue_logical_block_size(q), > STRING_UNITS_10, cap_str_10, sizeof(cap_str_10)); > > dev_notice(&vdev->dev, > - "new size: %llu %d-byte logical blocks (%s/%s)\n", > - (unsigned long long)capacity, > - queue_logical_block_size(q), > - cap_str_10, cap_str_2); > + "new size: %llu %d-byte logical blocks (%s/%s)\n", > + nblocks, > + queue_logical_block_size(q), > + cap_str_10, > + cap_str_2); > > set_capacity(vblk->disk, capacity); > revalidate_disk(vblk->disk); > -- > 2.13.3 >-------------- next part -------------- A non-text attachment was scrubbed... Name: signature.asc Type: application/pgp-signature Size: 455 bytes Desc: not available URL: <http://lists.linuxfoundation.org/pipermail/virtualization/attachments/20170804/15e3f096/attachment-0001.sig>
Michael S. Tsirkin
2017-Aug-04 13:24 UTC
[PATCH] virtio_blk: fix incorrect message when disk is resized
On Fri, Aug 04, 2017 at 10:37:54AM +0100, Stefan Hajnoczi wrote:> On Wed, Jul 26, 2017 at 03:32:23PM +0100, Stefan Hajnoczi wrote: > > The message printed on disk resize is incorrect. The following is > > printed when resizing to 2 GiB: > > > > $ truncate -s 1G test.img > > $ qemu -device virtio-blk-pci,logical_block_size=4096,... > > (qemu) block_resize drive1 2G > > > > virtio_blk virtio0: new size: 4194304 4096-byte logical blocks (17.2 GB/16.0 GiB) > > > > The virtio_blk capacity config field is in 512-byte sector units > > regardless of logical_block_size as per the VIRTIO specification. > > Therefore the message should read: > > > > virtio_blk virtio0: new size: 524288 4096-byte logical blocks (2.15 GB/2.0 GiB) > > > > Note that this only affects the printed message. Thankfully the actual > > block device has the correct size because the block layer expects > > capacity in sectors. > > > > Signed-off-by: Stefan Hajnoczi <stefanha at redhat.com> > > --- > > drivers/block/virtio_blk.c | 16 ++++++++++------ > > 1 file changed, 10 insertions(+), 6 deletions(-) > > Ping?Oops - I thought I sent it up. Will do.> > diff --git a/drivers/block/virtio_blk.c b/drivers/block/virtio_blk.c > > index 4e02aa5fdac0..69a2d1748743 100644 > > --- a/drivers/block/virtio_blk.c > > +++ b/drivers/block/virtio_blk.c > > @@ -381,6 +381,7 @@ static void virtblk_config_changed_work(struct work_struct *work) > > struct request_queue *q = vblk->disk->queue; > > char cap_str_2[10], cap_str_10[10]; > > char *envp[] = { "RESIZE=1", NULL }; > > + unsigned long long nblocks; > > u64 capacity; > > > > /* Host must always specify the capacity. */ > > @@ -393,16 +394,19 @@ static void virtblk_config_changed_work(struct work_struct *work) > > capacity = (sector_t)-1; > > } > > > > - string_get_size(capacity, queue_logical_block_size(q), > > + nblocks = DIV_ROUND_UP_ULL(capacity, queue_logical_block_size(q) >> 9); > > + > > + string_get_size(nblocks, queue_logical_block_size(q), > > STRING_UNITS_2, cap_str_2, sizeof(cap_str_2)); > > - string_get_size(capacity, queue_logical_block_size(q), > > + string_get_size(nblocks, queue_logical_block_size(q), > > STRING_UNITS_10, cap_str_10, sizeof(cap_str_10)); > > > > dev_notice(&vdev->dev, > > - "new size: %llu %d-byte logical blocks (%s/%s)\n", > > - (unsigned long long)capacity, > > - queue_logical_block_size(q), > > - cap_str_10, cap_str_2); > > + "new size: %llu %d-byte logical blocks (%s/%s)\n", > > + nblocks, > > + queue_logical_block_size(q), > > + cap_str_10, > > + cap_str_2); > > > > set_capacity(vblk->disk, capacity); > > revalidate_disk(vblk->disk); > > -- > > 2.13.3 > >
Maybe Matching Threads
- [PATCH] virtio_blk: fix incorrect message when disk is resized
- [PATCH] virtio_blk: fix incorrect message when disk is resized
- [PATCH] virtio_blk: print capacity at probe time
- [PATCH] sd, mmc, virtio_blk, string_helpers: fix block size units
- [PATCH] sd, mmc, virtio_blk, string_helpers: fix block size units